Skip to content

Assessment of Safety and Effectiveness of NovoSorb® BTM in Severe Burns

A Pivotal Study to Assess the Safety and Effectiveness of NovoSorb® Biodegradable Temporizing Matrix (BTM) in the Treatment of Severe Burn Skin Injuries

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04090424
Enrollment
150
Registered
2019-09-16
Start date
2021-09-21
Completion date
2026-12-01
Last updated
2026-02-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Burns

Brief summary

This is a multi-center, pivotal study to assess the safety and effectiveness of a new method of treating severe burns using NovoSorb® Biodegradable Temporizing Matrix (BTM).

Detailed description

This is a multi-center, pivotal study to assess the safety and effectiveness of a new method of treating severe burns using NovoSorb® Biodegradable Temporizing Matrix (BTM). A comparison will be made between burn wounds treated with BTM and the institution's standard of care (SOC).

Interventions

DEVICENovoSorb BTM

NovoSorb BTM comprises a completely synthetic, sterile, integrating dermal component (porous biodegradable polyurethane foam) and a temporary epidermal barrier component (a nonbiodegradable polyurethane sealing membrane). These layers are adhered with a biodegradable polyurethane bonding layer. BTM will be implanted and fixed into position to close a debrided burn wound. After a period of integration, the sealing membrane is removed and a split skin graft is applied.

PROCEDUREStandard of Care

Burn wounds will be treated using the institution's standard of care, e.g. primary skin grafting, cadaveric allograft followed by skin grafting.

Sponsors

PolyNovo Biomaterials Pty Ltd.
Lead SponsorINDUSTRY
Biomedical Advanced Research and Development Authority
CollaboratorFED

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

1. Provide written informed consent directly or via legal representative prior to any clinical study procedures being performed 2. Willing to comply with all study procedures and expects to be available for the duration of the study 3. Male and females ≥ 18 years of age and ≤ 75 years of age 4. Patients with deep dermal or full thickness burns between 3% and 60%, inclusive, of their total body surface area (TBSA). Types of burns include the following: * Scalding including from hot water, cooking oil, grease * Flame * Flash * Contact 5. Subjects who have staged surgical procedures planned e.g., one procedure to excise the burn injury and a later procedure to prepare the wound bed and apply an autologous skin graft. 6. The minimum total area across all lesions to have NovoSorb® BTM applied is 3% TBSA 7. Females, who are non-pregnant, naturally postmenopausal, or who agree to use effective contraceptive methods throughout the course of the study.

Exclusion criteria

1. Has a known hypersensitivity to polyurethane 2. Only a non-burn injury has been experienced by the subject including soft-tissue degloving and friction burn/crush, i.e., road rash 3. Multiple traumas, i.e., significant traumatic injury to a solid organ in addition to skin 4. Presence of a medical condition with a life expectancy of less than 12 months, such as advanced malignancy 5. Presence of a medical condition that might interfere with treatment evaluation; or require a change in therapy including but not limited to, significant immune deficiency, or skin or vascular diseases in the area of the wound 6. For females - has known or suspected pregnancy, planned pregnancy, or during lactation 7. Has exposure to any other investigational agent within the last 6 months 8. Has exposure to any other treatment/device that will interfere with NovoSorb® BTM integration 9. Anticipated inability to perform wound care and follow-up procedures 10. Anticipates of a level of non-compliance 11. The use of off-label treatments for full-thickness / deep-dermal burns is not permitted 12. Clinical signs of wound infection at areas to be potentially treated using NovoSorb® BTM that in the opinion of the investigator may compromise safety and study objectives 13. The use of NovoSorb® BTM on the face and in the perineum area is not permitted

Design outcomes

Primary

MeasureTime frameDescription
Proportion of study lesions in both groups with complete wound closure after skin grafting4 weeks after skin graftingAssessment of clinical outcome by wound closure

Countries

India, United States

Contacts

STUDY_DIRECTORMarcus Wagstaff, MBBS, PhD

Royal Adelaide Hospital, Adelaide SA 5000. Australia

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 25, 2026