Biosensors for Open and Closed-loop Glycemia Control in T1D Patients With Insulin Pump

Decoding Islet Algorithms in Biosensors for Open and Closed-loop Glycemia Control in T1D Patients With Insulin Pump Coupled to Sensors.

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04081883
Acronym
DIABLO
Enrollment
1
Registered
2019-09-09
Start date
2023-01-27
Completion date
2024-01-27
Last updated
2026-05-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes Mellitus, Type 1

Keywords

Continuous Glucose Monitoring, Biosensor

Brief summary

In T1D, the destruction of beta-pancreatic cells causes insulin deficiency and requires insulin therapy whose control remains complex: even with recent technologies of continuous measurement and monitoring of blood glucose (CGM), current systems are electrochemical, insulin therapy algorithms do not are not optimal and cannot completely eliminate vital risks such as hypoglycemia. A new biosensor connected to the patient by microdialysis, will be tested in a clinical trial in CHU-Bdx on 10 T1D patients with an internal or external insulin pump. In various daily scenarios (meals, physical exercise) the biosensor DIABLO responses will be compared to the measurements of standard CGM systems.

Detailed description

Continuous monitoring and linked drug delivery is a novel approach to the treatment of chronic diseases that provides powerful means to improve therapeutic outcomes and quality of patient's life. Type 1 diabetes (T1D) concerns 5 to 10% of the estimated 415 million cases of diabetes worldwide in 2016, expected to rise to 642 million by 2040(1). Continuous glucose monitoring systems (CGMS) linked to insulin delivery has provided a major advance(2). T1D is a serious, currently chronic and costly disease in children or young adults. Indeed, the destruction of pancreatic beta-cells leads to absolute insulin deficiency in T1D.

Interventions

OTHERBiosensor algorithm

The biosensor DIABLO responses will be compared to the measurements of standard CGMS, using blood glucose measures every 10 minutes by taking interstitial fluid from Diabetes Type 1 (DT1) patients with an internal or external insulin pump.

Sponsors

University Hospital, Bordeaux
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient over 18 years of age * Patient with type 1 diabetes (T1D) * Patient being equipped and trained with an external or internan insulin pump linked to a CGM * Affiliated person or beneficiary of a social security scheme * Free, informed and written consent

Exclusion criteria

* Patient under 18 years * Patient not having T2D * Pregnant or lactating patient * No consent signed by the patient

Design outcomes

Primary

MeasureTime frameDescription
Comparison between biosensor to CGMS responses2 days after inclusionMeasure blood glucose every 10 minutes by taking interstitial fluid from DT1 patients with an internal or external insulin pump to compare the biosensor responses to measurements of standard CGM systems.

Countries

France

Contacts

PRINCIPAL_INVESTIGATORBogdan CATARGI, Pr

University Hospital, Bordeaux

Outcome results