Comparison of Non-Invasive Blood Pressure (NIBP) Using the Biobeat Device with an Invasive Arterial Line Catheter

Comparison of Continuous Non-Invasive Blood Pressure Measurement Using the Wireless Cuffless Biobeat Monitor with an Invasive Arterial Line Catheter

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04071015
Enrollment
250
Registered
2019-08-28
Start date
2020-06-15
Completion date
2026-12-31
Last updated
2025-03-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Blood Pressure, Heart Diseases

Keywords

vital signs, blood pressure, cardiac surgery, non-invasive monitoring

Brief summary

In this clinical study the investigators will compare blood pressure measurements obtained using the non-invasive, wireless Biobeat monitoring device (both a wrist watch and a patch configuration) to an invasive arterial line catheter (radial or femoral) and a Swan Ganz Catheter in 20 patients immediately after cardiac surgery, at the cardiac intensive care unit.

Detailed description

The Biobeat non-invasive, wireless monitoring device is based on reflective photoplethysmograph (PPG) technology. It measures several vital signs, including blood pressure, stroke volume, pulse rate, pulse pressure, heart rate variability, respiratory rate, saturation, cardiac output, cardiac index, and more. The data is transmitted to Biobeat's application (in both Apple and Google Play), and is available on the individual's cellular phone, tablet, or as a full monitoring system in a hospital department. The aim of this study is to compare the Biobeat monitor with the invasive method of blood pressure measurement, an arterial line, and a Swan Ganz catheter for measurements of cardiac output and stroke volume. The study population includes 20 patients undergoing cardiac surgery. As per local protocol, each one of the participants will come out from the operating room with an arterial line, some will also have a Swan Ganz catheter. Once in the intensive care unit, the investigators will attach the Biobeat non-invasive monitor (both a wristwatch and a patch), these two configurations are identical in terms of the monitoring system), and monitor the participants for 4 hours. Though both methods are continuous, the investigators will record the vital signs every 15 minutes during the 4 hours of the study.

Interventions

Comparing blood pressure measurement using the Biobeat non-invasive monitor to arterial line.

Sponsors

The Chaim Sheba Medical Center
CollaboratorOTHER
Biobeat Technologies Ltd.
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* 18 years old and above patients of both sexes arriving immediately after cardiac surgery to the intensive care unit with a radial/femoral arterial line and or a Swan Ganz catheter and in need for blood pressure monitoring.

Exclusion criteria

* Refusal to participate * Patients with no need or no technical capability to have an arterial line * Pregnant women * Individuals under the age of 18 years * Patients with lack of judgment/mental illness * Patients working in the Sheba Medical Center

Design outcomes

Primary

MeasureTime frameDescription
Level of accordance between the Biobeat monitor and the arterial line4 hours per individualComparing blood pressure measurements of the Biobeat device with those of the arterial line. Both systolic blood pressure and diastolic blood pressure will be assessed during the study period.