Skip to content

Biological Allograft Chain Tissue Implant

The Biological Allograft Chain Tissue Implant & Associated Manual Surgical Instrumentation: A Prospective, Post-Market Study

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04064710
Enrollment
26
Registered
2019-08-22
Start date
2019-06-10
Completion date
2022-12-01
Last updated
2021-05-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Vertebral Body Compression Fracture(s)

Brief summary

A prospective, multi-center study evaluating allograft tissue as a bone void filler when implanted with Lenoss Medical manual surgical instrumentation in patients with painful vertebral compression fractures.

Detailed description

Vertebral compression fractures can be associated with instability and severe, persistent pain and limitation of activities. This post market study is being conducted to assess fracture stability over time.

Interventions

PROCEDUREVertebral Body Augmentation

Use allograft tissue in patients with one or two level, thoracic or lumbar T6-L5, vertebral compression fractures.

DEVICEManual Surgical Instruments

Lenoss Medical manual surgical access and cavity creation instruments will be used when implanting the allograft tissue.

Sponsors

MCRA
CollaboratorINDUSTRY
Lenoss Medical
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
50 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Skeletally mature adult ≥ 50 years of age at the time of surgery; 2. Currently in an independent living environment; 3. One- or two- level, acute (within six weeks of injury), thoracic or lumbar (T6-L5) vertebral body compression fracture(s) with evidence of marrow edema by MRI/CT; 4. Adequate vertebral body height and geometry for insertion of the access instruments, as determined by the investigator and suitable candidate for standard kyphoplasty or vertebroplasty procedure; 5. VAS back pain score ≥ 70 mm on a 100 mm scale; 6. Has central pain over the spinous process upon palpation at the planned vertebral index level; 7. Has failed prior non-surgical medical management (i.e. - physical therapy, narcotic and/or non-narcotic medication) 8. Psychosocially, mentally and physically able to fully comply with this protocol including adhering to scheduled visits, treatment plan, completing forms, and other study procedures; 9. Personally signed and dated informed consent document prior to any study-related procedures indicating that the patient has been informed of all pertinent aspects of the study.

Exclusion criteria

1. More than two levels with a vertebral compression fracture; 2. Previous treated or untreated vertebral compression fracture at the to be treated level(s); 3. Uncorrectable coagulopathy; 4. Previous instrumented spinal surgery; 5. Significant vertebral collapse defined as \> 70% of original vertebral height, or a burst, or pedicle fracture; 6. Degenerative scoliosis, defined as Cobb angle \> 20° at any level; 7. Pre-existing neurological deficit or radicular pain that is not well defined or unstable; 8. Disabling back pain secondary to causes other than acute fracture; 9. Inability to walk or stand prior to sustaining the vertebral compression fracture; 10. Active systemic or local infection; 11. Known history of Paget's disease, osteomalacia, or any other metabolic bone disease; 12. Morbid obesity defined as a body mass index \> 40 kg/m2; 13. Active malignancy. A patient with a history of any invasive malignancy (except nonmelanoma skin cancer), unless treated with curative intent and there has been no clinical signs or symptoms of the malignancy for more than 5 years; 14. Current or recent history (within last 2 years) of substance abuse (e.g., recreational drugs, narcotics, or alcohol); 15. Currently involved in study of another investigational product that may affect outcome; 16. History of psychosocial disorders that could prevent accurate completion of self reporting assessment scales; 17. Pregnant or planning to become pregnant during the study period; 18. Involved in active spinal litigation; 19. Involved in a workers compensation case; 20. Prisoner or ward of the state; 21. Unable to undergo a MRI/CT procedure.

Design outcomes

Primary

MeasureTime frameDescription
Evaluate fracture stability assessed via subject- reported pain over time12 monthsSubject-reported pain over time using the allograft tissue will be assessed using the Visual Analog Scale (VAS) for back pain on a scale of 0mm (no pain) to 100mm (worst pain imaginable).

Secondary

MeasureTime frameDescription
Measure of Physical Disability Assessed via the Roland Morris Disability Questionnaire12 monthsThe Roland Morris Disability Questionnaire is a widely used health status measure for physical disability caused by low back pain. Scores range from 0 to 24 with higher scores representing higher levels of pain-related disability.
Measurement of Quality of Life Assessed via the EuroQol Health Outcome Instrument (EQ-5D-3L)12 monthsThe EQ-5D-3L is a standardized instrument used as a measure of health outcomes. It contains questions in 5 dimensions (mobility, self-care, usual activities, pain/discomfort, and anxiety/depression) and provides a simple descriptive profile and single index for health status preference. In addition, there is a Visual Analog Scale (VAS). The VAS is the participant's rating of their health on a scale of 0 worst imaginable health state to 100 best imaginable health state.
Measurement of Activities of Daily Living Assessed via the Modified Tegner Activity Level Scale12 monthsThe Modified Tegner Activity Level Scale is designed to measure a patient's activities of daily living, recreation, and competitive sports. The scale includes an assessment of level of activity pre- and post- injury. The scores range from 0 to 10 with a 0 representing sick leave or disability.
Frequency of Implant Related Complications12 monthsThe frequency of allograft tissue related complications will be tabulated. Intra-operative complications, surgical time, and any other significant adverse events will be summarized as safety variables. Adverse events will be tabulated by physician's assessment of seriousness, severity, expectedness, the event's causative relation to the allograft tissue or the Access and Cavity Creation instruments, and by elapsed time since surgery. Adverse events that require secondary surgical intervention (SSI) will be flagged.

Countries

United States

Contacts

Primary ContactDom Messerli
dom.messerli@lenoss.com484-988-0477

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026