Skip to content

Effect of Protanopia on the Brightness Perception of Brake Lights

Investigation of the Effect of Protanopia (Red Blindness) on the Brightness Perception of Brake Lights and Their Effect on Reaction Time

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04060238
Acronym
ProLight
Enrollment
16
Registered
2019-08-19
Start date
2020-01-07
Completion date
2020-03-15
Last updated
2020-03-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Color Blindness, Red, Reaction Time

Keywords

protanopia, taillight, brake light, differential luminance sensitivity, contrast sensitivity, colour vision, colour vision defect, perimetry, semi-automated kinetic perimetry, traffic, motorist, reaction time

Brief summary

The aim of the offered project is to investigate the influence of protanopia (red blindness) or protanomaly (red vision weakness) on the recognizability of red brake lights with the help of a test person study. From this, estimates of the influence of protanopia or protanomaly on driving ability are to be derived. If a relevant influence can be demonstrated in the study, recommendations for action for the legislator will be made. Translated with www.DeepL.com/Translator

Detailed description

Protanopia is an x-chromosomal inherited cone pigment disorder that related to the red cone,i.e. the L-cone function completely fails. The prevalence of protanopia in the male population is 1%. An incomplete impairment of the L-cone is called protanomaly. The prevalence here is also in 1% of the male population. In comparison to persons with normal vision red objects appear darker for persons with missing or functionally limited L-cones. This is particularly critical in road traffic, where red is used as a signal colour, for example in traffic lights or brake lights is used. The scientific questions that need to be investigated are as follows: 1. At which contrast threshold (relative brightness) does a proband with protanopia recognize a brake light compared to a normal person? 2. If the luminance determined is above the contrast threshold, what influence does the excess of the contrast or the determined luminance have on the reaction time? 3. Are there differences with regard to the technology used in the brake light (incandescent lamp or LED)? For this purpose, a representative set of combination rear lamps, focusing on stoplight, taillight (and of the elevated brake light) in a static situation is created. The test setup is based on a driving pursuit scenario. The test person is positioned at a relevant distance to the combination of rear lamps. To determine the threshold contrast, an algorithm is developed to control the relative brightness of the brake lights and integrated into the test sequence control. In addition, a method for automated determining of the related reaction time is implemented. Two taillight technologies (incandescent lamp and LED) are examined at both ambient brightness levels: (i) bright, i.e. photopic luminance level (Lu \>\> 10 cd/m2) and (ii) dark, i.e. mesopic luminance level (Lu \< 10 cd/m2). A comprehensive ophthalmological/optical examination (including visual acuity, ocular alignment, ocular motility, assessment of the leading eye, testing of the efferent and afferent pupillary system and biomicroscopic inspection of the anterior and posterior segments of the eye) is carried out. Comprehensive colour vision testing it performed with the HMC anomaloscope, Oculus Inc., Dutenhofen/FRG, including assessment of the loss of brightness sensation during anomaloscopic exam with max. red. stimulus . In addition, standardized semi-automated kinetic perimetry (SKP) along the horizontal meridian with an automated perimeter (Octopus 900, Haag-Streit Inc., Koeniz/CH) is performed. The ratio of the horizontal extent (diameter) obtained with both, red vs. white stimuli, is measured and taken as a clinical parameter for quantifying the magnitude of the individual protan colour vision deficiency. To illustrate the worst-case scenario, this study is limited to protanopic patients. It is intended as a pure comparative study between a protanopic patient group and a normal vision control group. The protanopic test subjects and the control subjects are matched with regard to gender and age. This study is carried out in a within-subject design, i.e. all test persons go through all situations. In order to minimize sequence effects, the related test conditions are randomized.

Interventions

DIAGNOSTIC_TESTAnomaloscope (colour vision test)

The Heidelberg Multi Colour (HMC) Anolmaloscope (Oculus Inc., Dutenhofen/FRG) is used to differentiate between normal controls (normal trichromatopsia) and test subjects with protanopia (inherited red colour blindness)

Sponsors

Karlsruhe Institute of Technology (KIT), Karlsruhe/FRG
CollaboratorUNKNOWN
Aalen University
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
MALE
Age
18 Years to No maximum

Inclusion criteria

* informed consent * male * age (greater or equal) 18 years

Exclusion criteria

* binocular (high contrast) distant visual acuity worse than 0.8 (16/20) * spherical ametropia exceeding 8 dpt * cylindrical ametropia exceeding 2.5 dpt * manifest strabismus (squint) with diplopia * relative afferent pupillary defect exceeding 0.3 log units * anamnestic (patient history) OR morphological (slit lamp --\> anterior segment, ophthalmoscope --\> retina) clue/indicator for a ophthalmologically relevant affection of the eye OR the visual pathway * S.p. severe ocular trauma * Current OR s.p. severe intraocular inflammation * S.p. intraocular surgery within the past three months

Design outcomes

Primary

MeasureTime frameDescription
Contrast sensitivity (I)within one yearContrast sensitivity between taillight and brake light under two luminance conditions

Secondary

MeasureTime frameDescription
Reaction timewithin one yearTime span within the onset of the brake light and the reaction of the tested subject
Contrast sensitivity (II)within one yeartaillight technology: incandescent lamp vs. light emitting diode (LED)
Reaction time (II)within one yeartaillight technology: incandescent lamp vs. light emitting diode (LED)
Perimetric extent of horizontal meridianwithin one year(Semi-autmated kinetic) perimetry with white vs. red stimuli
Loss of brightness sensation during anomaloscopic examwithin one yearLoss of brightness sensation during anomaloscopic exam with max. red. stimulus

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026