Skip to content

PMCF Study of LiquiBand FIX8® OHMF Device

PMCF Study to Evaluate the Safety and Performance of LiquiBand FIX8® Open Hernia Mesh Fixation Device

Status
Active, not recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04059640
Acronym
LBF8-Open
Enrollment
109
Registered
2019-08-16
Start date
2021-12-07
Completion date
2026-07-31
Last updated
2025-10-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Inguinal Hernia

Keywords

Inguinal Hernia, Mesh Fixation, Surgical Site Wound Closure

Brief summary

Study to evaluate the safety and performance of LiquiBand FIX8® Open Hernia Mesh Fixation Device.

Interventions

DEVICELiquiBand FIX8 Open Hernia Mesh Fixation Device

Subjects will undergo hernia mesh fixation and topical wound closure using the LiquiBand FIX8® OHMF device. Subjects will be evaluated intra-operatively, post-operatively, at discharge, and at 12 months post-operatively. The Liquiband surgical study device is considered a permanent implant.

Sponsors

Imarc Research, Inc.
CollaboratorINDUSTRY
Advanced Medical Solutions Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Subject is able to understand and give informed consent to take part in the study * Subject has a primary inguinal hernia. * Subject is scheduled to undergo open inguinal hernia repair using the LiquiBand FIX8® OHMF device. * Subject is willing and able to comply with the protocol assessments at time of surgery and during the post-surgical follow-up period.

Exclusion criteria

* Subject is undergoing open repair surgery for recurrent hernia, where the primary surgery was also open. Subjects with recurrent hernia whose primary surgery was laparoscopic are not excluded. * Subject has an anatomical defect or had prior surgical procedures that in the opinion of the investigator makes them unsuitable for open hernia repair with the LiquiBand FIX8® OHMF device. * Subject is known to be non-compliant with medical treatment. * Subject is pregnant or actively breastfeeding. * Subject has any significant or unstable medical or psychiatric condition that, in the opinion of the Investigator, would interfere with his/her ability to participate in the study. * Subject has a known sensitivity to cyanoacrylate or formaldehyde, D&C Violet No.2 dye or any other component of LiquiBand FIX8® OHMF device. * The hernia mesh to be used in the repair is constructed from Polytetrafluoroethylene (PTFE) or absorbable materials. * The hernia mesh to be used in the repair is a self-gripping mesh (e.g. ProGrip). * Subject has active or potential infection at the surgical site. * Subject has a history of keloid formation. * Subject has a known vitamin C or zinc deficiency. * Subject has a connective tissue disorder.

Design outcomes

Primary

MeasureTime frameDescription
Effectiveness of the LiquiBand FIX8 OHMF deviceTime of surgeryEffectiveness will be defined as successful fixation of the hernia mesh (ie not requiring additional fixation by an alternate device) using the LiquiBand FIX8 device at the time of surgery. Based on data pooled from published studies of a similar device (which employs the same cyanoacrylate glue to fix hernia mesh, via a laparoscopic rather than open surgical approach), there has been an observed failure rate of 0.8% in mesh fixation. This study aims to demonstrate non-inferiority of the LiquiBand FIX8 device to a failure rate of 5% (medically acceptable inference).

Secondary

MeasureTime frameDescription
Safety of the LiquiBand FIX8 OHMF device0 (intra-operatively), up to 2 days (discharge from hospital) and 12-months post surgeryThe incidence of adverse events (whether or not determined to be related to the LiquiBand FIX8 Device) will be recorded. Complications assessed during the study will include: * Haematoma * Seroma * Testicular ischaemia and atrophy * Surgical site or wound infection/dehiscence * Mesh infection * Chronic post-operative pain (lasting ≥ 12 months post-surgery
Effectiveness of the LiquiBandFIX8 OHMF device for topical wound closureTime of surgeryDefined as successful closure of the incision site using the LiquiBand FIX8 Device (not requiring additional fixation by an alternate device).
Assessment of chronic post-operative pain using the Visual Analogue Scale: the minimal clinically important difference and patient acceptable symptom state.12-months post-surgeryChronic post-operative pain will be assessed using the following measures: * Improvement in post-operative pain from baseline to 12 months post-surgery as measured by the Visual Analogue Scale (0 = no pain to 10 = most pain imaginable); and * Analgesic requirements in the 12 months post-surgery
Comparison of cost-effectiveness of patients treated with the LiquiBand FIX8 OHMF device compared with costs for those treated using standard surgical technique.12-monthsA study-specific outcome model will be used, which will calculate an incremental cost effectiveness ratio (ICER) in terms of quality-adjusted life years (QALYs) achieved with the introduction of the LiquiBand FIX8 OHMF device compared with using a standard surgical technique (suture fixation).
Comparison of costs of patients' clinical events treated with the LiquiBand FIX8 OHMF device compared with costs for those treated using standard surgical technique.12-monthsA study-specific outcome model will be used which will calculate an incremental cost effectiveness ratio (ICER) given in terms of clinical events avoided achieved with the introduction of the LiquiBand FIX8 OHMF device compared with using a standard surgical technique (suture fixation).
Clinician satisfaction0 (Post Surgery) and upto 2 days (hospital discharge)Users will be asked to rate the device on factors relating to ease of use and satisfaction, compared with their experience of other hernia mesh fixation devices. Satisfaction will be assessed using a Likert-type scale (e.g. Very satisfied (1), Satisfied (2), Neither (3), Dissatisfied (4), Very dissatisfied (5))
Long term performance of the study device12-months post surgeryLong-term performance will be assessed by rate of hernia recurrence.

Other

MeasureTime frameDescription
Cosmesis of wound closure using the Visual Analogue Scale12-monthsCosmesis of the wound closure will be assessed by the investigator and patient, and measured by Visual Analogue Scale (0 = Very poor cosmetic outcome; to 10 = very good cosmetic outcome).

Countries

United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026