Skip to content

3D Printing for Nodule Localization

Three-dimensionally Printed Navigational Template for Localizing Small Pulmonary Nodules

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04056923
Enrollment
47
Registered
2019-08-14
Start date
2018-01-01
Completion date
2018-07-01
Last updated
2019-08-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Lung Cancer, Pulmonary Nodule, Solitary

Keywords

Pulmonary Nodules, Lung Neoplasms, Computed Tomography, Three-Dimensional Printing

Brief summary

Implementation of lung cancer screening using low-dose computed tomography has increased the rate of detection of small peripheral pulmonary nodules. However, it is hard to localize these nodules by palpation because of their small volume and long distance to the nearest pleural surface. To further clarify the confounding factors, we developed our own 3D printing localization procedure. In contrast to traditional CT-G percutaneous puncture localization, our procedure was performed in the operating room without CT scan evaluation.

Detailed description

Pulmonary wedge resection is one of the most common types of operations performed by thoracic surgeons, especially given that more and more patients with ground glass nodules are being detected recently. One of the most significant current discussion concerning wedge resection is nodule localization. At present, a commonly used localization method is the CT-guided percutaneous lung puncture methylene blue staining marker localization, but this method has two main disadvantages: 1. the methylene blue dye is easy to spread, affecting the intraoperative judgment of nodule position by surgeon; 2. patients often suffer additional CT radiation. In recent years, the three-dimensional (3D) printing technique has been gradually applied to clinical therapy. However, 3D-printed template-guided (3D-G) localization required pre-evaluation by CT scanning. If deviation of more than 2 cm was found on the CT scan, the 3D-G method was regarded as a failure and traditional CT-G hookwire localization was used. To further clarify the confounding factors, the investigators developed their own 3D printing localization procedure. In contrast to traditional CT-G percutaneous puncture localization, the 3D printing localization procedure was performed in the operating room without CT scan evaluation.

Interventions

PROCEDURE3D-printing guided

3D printed navigational template guided

PROCEDURECT-guided

CT-guided

DRUGIndocyanine Green

The results are shown by comparison of different colors.

DRUGMethylene blue

The results are shown by comparison of different colors.

PROCEDUREPreoperative

Preoperative localization.

Intraoperative localization.

Sponsors

Zhuhai Seine Technology Co., Ltd, Zhuhai city, China
CollaboratorUNKNOWN
Wen-zhao ZHONG
Lead SponsorUNKNOWN

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* a maximum target lung nodule diameter ≤20 mm; * a target nodule consolidation/tumor ratio (CTR) \<0.25, or a minimum distance from the outer edge of the nodule to the nearest pleural surface \>10 mm if the target nodule CTR was \>0.25.

Exclusion criteria

* Inability to comply with research protocols or research procedures * Any unstable systemic disease (including active infections, uncontrolled high blood pressure, unstable angina, angina pectoris that has started within the last 3 months, congestive heart failure (≥ New York Heart Association \[NYHA\] Level II ), cardiac infarction (6 months before enrollment), severe arrhythmia requiring medication, liver, kidney or metabolic disease * Active bleeding; Inability to withstand lying flat; Inability to cooperate through breathing during puncture * Pregnant or lactating women * Other circumstances that the investigator believes are not suitable for enrollment

Design outcomes

Primary

MeasureTime frameDescription
Localization distanceDay of surgeryThe distance of the two stain points from the tumor. The investigators use a sterile, standard ruler to measure the distance. Based on our previous experience with CT-G localization, a deviation of less than 2 cm was considered a successful localization.

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026