Study of the Analytical Performance of ALLEGRO™ Instrument

Study of the Analytical Performance of ALLEGRO™ Instrument: Performance Evaluation of In Vitro Diagnostic Device

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04035044
Enrollment
50
Registered
2019-07-29
Start date
2017-06-01
Completion date
2018-06-01
Last updated
2019-07-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes

Brief summary

A new analyser has been developed (Allegro™) which allows the tests to be undertaken at the clinic, with the results available in a few minutes. This means that patients can get immediate feedback and that the doctors/nurses can adjust treatment before the patient leaves the clinic. It is obviously important that this analyser performs to a similar degree of accuracy to the laboratory analyses.

Detailed description

Blood and urine tests are used in the assessment of diabetes and to guide clinical management. In the traditional model of care, blood samples are taken from patients at the clinic and are sent to the laboratory for analysis and the results may not be available for a number of hours/days after the clinic visit. A new analyser has been developed (Allegro™) which allows the tests to be undertaken at the clinic, with the results available in a few minutes. This means that patients can get immediate feedback and that the doctors/nurses can adjust treatment before the patient leaves the clinic. It is obviously important that this analyser performs to a similar degree of accuracy to the laboratory analyses. The aim of this research study is to assess the accuracy of the Allegro™ analyser compared to laboratory analyses on finger prick capillary blood samples and urine samples. Fifty (50) patients with diabetes will be invited to give a venous blood sample, finger prick capillary blood sample and urine sample. The venous blood sample, finger prick capillary blood sample and urine sample will be analysed by both the Allegro™ analyser and laboratory analyses and the results compared. The Allegro™ results will not be used in the management of the patients' diabetes.

Interventions

None listed

Sponsors

C-TRIC
CollaboratorUNKNOWN
Nova Biomedical
Lead SponsorINDUSTRY

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years

Inclusion criteria

* Diabetes patients attending Altnagelvin Area Hospital Clinics or primary care in Western Trust area aged 18-80 years of age

Exclusion criteria

* Patients who are less than 18 years or over 80 years of age

Design outcomes

Primary

MeasureTime frameDescription
Analytical verification of Allegro - HbA1c comparison10 minutesAllegro™, a point of care testing instrument is as effective as a reference laboratory method for HbA1c blood results in mmol/mol
Analytical verification of Allegro - Cholesterol comparison10 minutesAllegro™, a point of care testing instrument is as effective as a reference laboratory method for Cholesterol blood results in mmol/L
Analytical verification of Allegro - HDL comparison10 minutesAllegro™, a point of care testing instrument is as effective as a reference laboratory method for HDL blood results in mmol/L
Analytical verification of Allegro - Triglycerides comparison10 minutesAllegro™, a point of care testing instrument is as effective as a reference laboratory method for Triglycerides blood results in mmol/L
Analytical verification of Allegro - Glucose comparison10 minutesAllegro™, a point of care testing instrument is as effective as a reference laboratory method for Glucose blood results in mmol/L
Analytical verification of Allegro - Creatinine comparison10 minutesAllegro™, a point of care testing instrument is as effective as a reference laboratory method for Creatinine blood results in mg/dL
Analytical verification of Allegro - Urine creatinine comparison10 minutesAllegro™, a point of care testing instrument is as effective as a reference laboratory method for Creatinine urine results in mg/dL
Analytical verification of Allegro - Urine Albumin comparison10 minutesAllegro™, a point of care testing instrument is as effective as a reference laboratory method for Albumin urine results in g/L