Stress Urinary Incontinence
Conditions
Keywords
Single-Incision Sling, Stress Urinary Incontinence, Failure
Brief summary
The main risk factors for failure after single-incision slings are reduced urethral mobility and stress urinary incontinence severity in long-term follow-up.
Detailed description
The medical records of the 132 patients were retrospectively analyzed. Preoperative assessment included medical history and urogynecological examination. Patients were asked to answer validated questionnaires such as Urinary Distress Inventory (UDI-6) and Incontinence Impact Questionnaire (IIQ-7). Objective cure of SUI was defined as the absence of demonstrable leakage of urine on the cough stress test. Subjective cure was based on negative response to UDI-6, question 3. Patients were divided according to objective cure rate into two groups: cured (Group A) and failed patients (Group B).
Interventions
The women with stress urinary incontinence underwent single-incision sling procedure.
Sponsors
Study design
Eligibility
Inclusion criteria
Women who underwent single-incision sling procedure for stress urinary incontinence
Exclusion criteria
Urodinamically proven detrusor overactivity Neurogenic bladder Previous anti-incontinence surgery including midurethral slings Postvoidal residual volume (PVR) \>100mL Previous radical pelvic surgery Anterior pelvic organ prolapse greater than stage I
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| objective cure | September 2009 to September 2017 | negative cough stress test |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| subjective cure | September 2009 to September 2017 | negative response to Urinary Distress Inventory (UDI-6), question 3. |
Countries
Turkey (Türkiye)