Skip to content

Performance and Safety Evaluation of a Novel Non-invasive Glucose Monitoring Device

Performance and Safety Evaluation of a Novel Non-invasive Glucose Monitoring Device

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04031300
Enrollment
0
Registered
2019-07-24
Start date
2019-06-01
Completion date
2019-06-01
Last updated
2023-11-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes Mellitus

Keywords

Non-invasive glucose monitoring, Raman spectroscopy

Brief summary

This pivotal multicenter study has been launched to collect spectral Raman data paired with validated glucose reference values in diabetic patients.

Detailed description

Participants will be enrolled at six different sites in four different countries. All participants will undergo identical procedures, which include four steps: Baseline visit (1 day), calibration period (25 days), validation period (23 days) and a close-out visit (1 day) with a total duration of 50 days. The calibration period consists of 23 home-based days and two in-clinic days. At the two in-clinic days, measurement sessions are performed every 30 minutes. A measurement session consists of two reference measurements (Contour Next One) and three measurements on the Investigational Medical Device. The glucose level of the participants is manipulated by administration of a glucose rich drink. At home-based days, the subject must perform four measurement sessions a day. During the validation period, participants perform up to four home-based measurement sessions a day.

Interventions

Investigational Medical Device collecting spectral Raman data non-invasively from tissue

Sponsors

RSP Systems A/S
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Male and female subjects ≥18 years of age * Diagnosed with diabetes, all types except gestational diabetes * Skin phototype 1-4 * Willing to perform a minimum of 8 finger sticks during each day of home-based measurements and 30 finger sticks at the two in-clinic study days * Subject has a wireless internet connection at home to be used in the study

Exclusion criteria

* For female subjects: Pregnancy or subject is attempting to conceive or not willing and able to practice birth control during the study duration * For female subjects: Breastfeeding * Subject currently participating in another study * Subject not able to understand and read the local language * In investigator's opinion, subject is not able to follow instructions provided and as specified in the protocol * Subject not able to hold hand/arm steady (including tremors and Parkinson's Disease) * Subject diagnosed with cardiovascular diseases * Reduced circulation in right hand evaluated by Allen's test * Subjects receiving anticoagulants, active cancer treatment, tetracyclines and other medication/topical agents increasing photosensitivity * Radiotherapy for the past six months * Extensive skin changes, tattoos or diseases on right hand thenar (probe application site) * Known allergy to medical grade alcohol used to clean the skin * Medical history or any condition that may, in the opinion of the investigator compromise the subject's ability to participate * Comorbidity or concomitant medical condition which, in the opinion of the Investigator, could interfere with the study or present a risk to the safety or welfare of the subject or study staff

Design outcomes

Primary

MeasureTime frameDescription
Measurement accuracy6 monthsAccuracy of measurements performed on the IMD will be evaluated by data from subjects. Data will be analyzed by Mean Absolute Relative Difference (MARD).
Safety evaluation: paucity of adverse events6 monthsSafety of the IMD will be evaluated in a descriptive manner by the paucity of adverse events reported during the clinical study

Secondary

MeasureTime frameDescription
Device deficienciesUp to 6 monthsDescription of device deficiencies will be listed. Deficiencies will be reported during the clinical study.
Device usability6 monthsThe use of the device will be evaluated by means of questionnaires. The subjects are asked if they encountered any problems during measurements, and if so, to elaborate the problems encountered.

Countries

Denmark, Germany, Sweden, United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026