Skip to content

CAVA: Dizziness Trial

Production of a Device to Obtain Continuous Ambulatory Vestibular Assessment (CAVA) - Dizziness Trial

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04026516
Acronym
CAVA
Enrollment
29
Registered
2019-07-19
Start date
2019-07-01
Completion date
2025-10-31
Last updated
2026-08-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Benign Paroxysmal Positional Vertigo, Meniere's Disease, Recurrent Vestibulopathy, Vestibular Migraine

Keywords

eye movements, Electronystagmograpy, nystagmus, electrooculogram, vestibular assessment, ambulatory monitoring

Brief summary

Clinical investigation of a medical device (CAVA) for recording eye movements. Patients suffering from diagnosed dizziness conditions will wear the device for 23 hours a day, for 30 days. The device will capture normal eye movement data as well as data corresponding to any dizzy events experienced. At the end of the trial, the data will be downloaded and a scientist will perform a blinded analysis of the data. Specifically, they will attempt to identify the dates on which dizziness was reported.

Detailed description

Dizziness is a common condition that is responsible for a significant degree of material morbidity and burden on our health service. There are multiple causes of dizziness, and these originate from pathologies affecting a large variety of different organ systems. Dizziness is usually episodic and short-lived, so when a patient presents to their health care provider, examination is often normal. As such, diagnosis is challenging and patients often experience significant delay in receiving a diagnosis. The investigators have developed a prototype device for monitoring dizziness and have tested it in a group of 17 healthy volunteers. The results showed that their device is capable of accurately, precisely and reliably identifying short periods of induced nystagmus (eye movements produced during dizzy attacks) among days' worth of normal eye movement data. The overall aim of this trial is to test a fully evolved device for the continuous recording of eye movements over a prolonged period of time, on patients suffering from dizziness. For the purpose of this study, the monitoring period is 23 hours a day, for 30 days. The device is composed of two components: a bespoke single-use sensor array that adheres to the participant's face, and a small reusable module that contains a battery, microcomputer, data storage facility, battery and connection port. The investigators intend to confirm that the device data can be used to identify any occurrence of nystagmus, as produced during attacks of vertigo. Each trial participant will be provided with the device and enough single-use electrode arrays to allow the array to be changed every 24 hours, for thirty days. Participants will be allowed to remove the sensor array for up to 60 minutes each day to allow them to wash and/or shower. If patients experience an episode of dizziness during the trial, they are required to log the details of the event in a trial diary. The identity of these days will not be revealed to the blinded investigator who will later conduct a formal, blinded analysis of the data. At the end of the thirty-day trial, the sensitivity and specificity of the device will be determined by assessing whether the data can be used to correctly identify the dates that participants reported dizziness.

Interventions

DEVICECAVA Device

The CAVA device will be worn continuously for thirty days, during which time it will record eye and head movements

Sponsors

Norfolk and Norwich University Hospitals NHS Foundation Trust
Lead SponsorOTHER
University of East Anglia
CollaboratorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Adults aged 18 and over. * Patients experiencing episodes of true vertigo, with at least two episodes within the preceding month. Relevant medical conditions include Meniere's disease, Benign Paroxysmal Positional Vertigo (BPPV), recurrent vestibulopathy and vestibular migraine. * Able to commit to 30 days of continuous wear of the trial device as per the study plan. * Own a telephone.

Exclusion criteria

* Potential participants who have a history of dermatological disease, fragile skin, or damage around the forehead. * Potential participants who have an allergy to plasters and/or medical adhesives - (similarly to materials used in the device). * History of hypertension or cardiac problems (uncontrolled, acute or de-compensated - phase). * History of ear disease, or previous ear surgery. * History of psychotic/neurotic disorders or epilepsy. * History of eye disease, or previous eye surgery. * Pregnant or nursing mothers. * Potential participants who have taken part in a previous CAVA trial. * Potential participants who are currently taking part in another trial. * Unable to follow the testing protocol.

Design outcomes

Primary

MeasureTime frameDescription
Nystagmus detection sensitivity and specificity of 95%30 daysThe investigators will determine the sensitivity and specificity of the results obtained by a bespoke computer algorithm for detecting episodes of nystagmus, from data captured by the CAVA device.

Secondary

MeasureTime frameDescription
Post-trial participant questionnaire30 daysA questionnaire will be provided to the participants at the end of the trial to gather data on device acceptability and other patient feedback. A qualitative assessment of this data will be performed. The device acceptability is measured over 8 questions regarding comfort of wear, ease of wear, self consciousness, effect on sleep with each question having a scale of 1-5. With 5 being the best outcome and 1 being the worst outcome.
Compliance with wearing the device30 daysInvestigators will check the participants compliance of wearing the device by using the data in the participants' trial diaries.
Functionality of the device's accelerometer30 daysData will be downloaded from the device and manually checked to ensure that valid data has been captured.
Functionality of the device's event marker30 daysData will be downloaded from the device and manually checked to ensure that the known dates and times of event marker activation match the record stored on the device.
Functionality of the device's timestamping capabilities30 daysThe known dates and times of event marker activations will be compared to the record stored on the device. From this information, clock drift will be calculated (hh:mm:ss).

Countries

United Kingdom

Contacts

PRINCIPAL_INVESTIGATORJohn Phillips, Consultant

Dr

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Aug 11, 2026