Skip to content

Closed-loop Double-vasopressor Automated System to Treat Hypotension During Spinal Anaesthesia for Caesarean Section

Closed-loop Double-vasopressor Automated System vs Manual Bolus Vasopressor to Treat Hypotension During Spinal Anaesthesia for Caesarean Section

Status
Completed
Phases
Phase 2Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04025918
Enrollment
216
Registered
2019-07-19
Start date
2011-10-01
Completion date
2012-07-01
Last updated
2026-08-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypotension

Keywords

hypotension, spinal anesthesia, cesarean section, phenylephrine, ephedrine, closed-loop system, continuous non-invasive monitor

Brief summary

Hypotension occurs commonly during spinal anesthesia for caesarean section with maternal and fetal adverse effects. The investigators developed a double-vasopressor automated system incorporating continuous non-invasive arterial pressure monitoring (CNAP, CNSystems, Austria).

Detailed description

Hypotension occurs commonly during spinal anesthesia for cesarean section with maternal and fetal adverse effects. The investigators developed a double-vasopressor automated system incorporating continuous non-invasive arterial pressure (CNAP, CNSystems, Austria) monitoring feeding hemodynamic data to a laptop computer, which triggers syringe pumps to deliver phenylephrine 50mcg or ephedrine 4mg (if heart rate\<60 beats.min-1) every 30 seconds when systolic blood pressure fell to below 90% of baseline. A randomised controlled trial was done to compare with manual bolus technique. With the manual bolus technique, phenylephrine 100mcg or ephedrine 8mg (if heart rate\<60 beats.min-1) was given every 60 seconds by the attending anesthesiologist when systolic blood pressure was below 90% of baseline as measured by conventional intermittent non-invasive blood pressure monitoring.

Interventions

DEVICEVasopressor automated delivery system

Novel closed-loop system incorporating: 1. Continuous non-invasive arterial pressure (CNAP) monitor that measured and recorded hemodynamic data in real time. 2. Controller algorithm loaded onto a laptop computer that monitored the hemodynamic data from CNAP and determined if vasopressors should be administered. 3. Two syringe pumps loaded with phenylephrine and ephedrine that was activated by the controller algorithm.

DRUGPhenylephrine

Phenylephrine is a vasopressor drug that was administered when the participant's systolic blood pressure fell below 90% of baseline systolic blood pressure, with heart rate of at least 60bpm.

DRUGEphedrine

Ephedrine is a vasopressor drug that was administered when the participant's systolic blood pressure fell below 90% of baseline systolic blood pressure, with heart rate of less than 60bpm.

DEVICEManual vasopressor delivery system

Manual dosing system consisting: 1. Non-invasive intermittent blood pressure monitor that measured and recorded blood pressure at 1-minute intervals. 2. Attending anesthesiologist that noted the blood pressure readings and manually administered phenylephrine or ephedrine according to the algorithm.

Sponsors

KK Women's and Children's Hospital
Lead SponsorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Caregiver, Investigator)

Eligibility

Sex/Gender
FEMALE
Age
21 Years to 45 Years
Healthy volunteers
Yes

Inclusion criteria

* age 21-45 years old, * weight 40-90 kg, * height 145-170 cm

Exclusion criteria

* contraindications to spinal anaesthesia, * allergy to drugs used in the study, and * those with uncontrolled medical conditions such as hypertension, diabetes mellitus, and cardiovascular disease

Design outcomes

Primary

MeasureTime frameDescription
Hypotension1 dayIncidence of systolic blood pressure less than 80% of baseline systolic blood pressure

Secondary

MeasureTime frameDescription
Hypertension1 dayIncidence of systolic blood pressure more than 120% of baseline systolic blood pressure
Nausea and vomiting1 dayIncidence of nausea and vomiting during cesarean section

Contacts

PRINCIPAL_INVESTIGATORBan Leong Sng, FANZCA

KK Women's and Children's Hospital

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Aug 7, 2026