A Ring-type Wearable Device for Atrial Fibrillation Among Ambulatory Patients

CART Phase 3 Study: Diagnostic Performance of a Ring-type Wearable Device Using Deep Learning Analysis of Photoplethysmographic Signals for Detecting Atrial Fibrillation Among Ambulatory Patients

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04024124
Enrollment
100
Registered
2019-07-18
Start date
2019-05-10
Completion date
2023-08-31
Last updated
2020-03-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation

Keywords

Atrial fibrillation, Deep learning, Diagnosis, Photoplethysmography, Wearable electronic devices

Brief summary

This study investigates diagnostic performance of a ring-type wearable device for detecting atrial fibrillation. This is a prospective cohort registry study began after the date of IRB approval and until 31th Dec. 2023. The eligible criteria are (1) those who admitted the institution for elective direct-current cardioversion or catheter ablation of persistent atrial fibrillation, (2) those who were successfully converted to sinus rhythm after the intervention, and (3) aged 19 years or more. The exclusion criteria are (1) those aged less than 19 years, (2) those who are not converted to sinus rhythm after the intervention, and (3) those who are not eligible to measure photoplethysmographic signals. This study aims to recruit 100 participants in total. The participants are required to record photoplethysmographic signals by the ring device in addition to routine procedures of direct-current cardioversion or catheter ablation, hence, the study is at minimal risk.

Detailed description

1. Study title: Diagnostic Performance of a Ring-type Wearable Device Using Deep Learning Analysis of Photoplethysmographic Signals for Detecting Atrial Fibrillation Among Ambulatory Patients. 2. Study type: Investigator initiated study. 3. Study design: Prospective observational cohort registry design. 4. Sponsor: Sky Labs, Inc., Republic of Korea. 5. The aim of the study: To evaluate diagnostic performance of a ring-type wearable device for detecting atrial fibrillation among ambulatory patients. 6. Study period: From the date of IRB approval to 31th Dec. 2023. 7. The size of study population: 100 participants 8. The eligibility criteria: (1) Those with persistent atrial fibrillation (2) Those who admitted the institution for elective direct-current cardioversion or catheter ablation (3) Those who are successfully converted to sinus rhythm (4) Those aged 19 years or more 9\. The exclusion criteria: 1. Those with other forms of cardiac arrhythmias 2. Those aged less than 19 years 3. Those who are not eligible to perform electrical cardioversion or catheter ablation 4. Those who are not converted to sinus rhythm after the intervention 10\. Procedures of the study 1. A participant is under the routine procedures of direct- current cardioversion or catheter ablation. 2. On admission, a participant is given with detailed information of the study. 3. After the informed consent, the only additional procedure due to the study is recording photoplethysmographic signal by wearing a ring-type device. The participant is instructed how to use the ring device. 4. Recorded signals are evaluated without encompassing persornal information. 5. The participant is required to wear the ring device and Holter monitoring device, and record his or her photoplethysmographic signals with ambulatory electrocardiography during the day. The ring is designed to automatically record user's photoplethysmographic signals and wirelessly transmit the data to user's smartphone. Detailed timings of wearing on/off the ring device and the Holter device are informed by a designated research crew. 6. The participant visits outpatient clinic as scheduled accordingly. At the clinic, the participant returns the ring device, Holter monitoring device, and the recorded data to the designated researcher crew. 7. Throughout the study, there is no intervention to the participants. The only additional step due to the participation of the study is that wearing the ring device and Holter monitoring device during their daily lives until the next outpatient clinic. 11\. Financial benefits to the participants: None.

Interventions

None listed

Sponsors

Sky Labs Inc.
CollaboratorUNKNOWN
Seoul National University Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
19 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Those with persistent atrial fibrillation * Those who admitted for elective direct-current cardioversion or catheter ablation * Those who are successfully converted to sinus rhythm * Those who aged 19 years or more

Exclusion criteria

* Those who aged less than 19 years * Those who had other types of cardiac arrhythmias * Those who are not eligible to perform electrical cardioversion or catheter ablation * Those who are not converted to sinus rhythm

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic performance1 month (from the discharge to the next outpatient clinic)Diagnostic performance of a ring-type wearable device for detecting atrial fibrillation (parameters including sensitivity, specificity, positive predictive value, negative predictive value).

Countries

South Korea

Contacts

Primary ContactEue-Keun Choi, MD, PhD
choiek417@gmail.com+82-2-2072-0688
Backup ContactSoonil Kwon, MD
david.soonil.kwon@gmail.com+82-10-9498-1664