Diastolic Hyperemia Free Index for Assessment of Moderate Coronary Stenoses

Diastolic Hyperemia Free Index for Assessment of Moderate Coronary Stenoses

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04019535
Acronym
DFRiFR
Enrollment
88
Registered
2019-07-15
Start date
2019-08-22
Completion date
2023-12-31
Last updated
2025-01-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Keywords

Physiologic assessment

Brief summary

A total of 106 subjects will be enrolled at up to 3 sites. Initial enrollment will occur at Washington University only. After 15 subjects have been enrolled at the primary site and no serious adverse events or protocol events have occurred the additional sites will be trained and added to enrollment.

Detailed description

With the release of DEFINE-FLAIR and iFR SWEDEHEART, coronary physiology and namely iFR, have robust clinical data supporting its routine use in the cardiac catheterization lab. Unfortunately, iFR is a proprietary algorithm owned by Phillips Volcano Corporation (San diego, California, USA) limiting the use of iFR to those centers with Volcano hardware. Whole cardiac cycle Pd/Pa has been another resting measure that has been evaluated and generally performs poorly compared to FFR. Although iFR is measured during the wave free period in diastole, to date there has been no assessment of diastolic Pd/Pa measurements and its potential correlation with the severity of coronary stenoses. Most importantly, evaluating the pressure differential across the entirety of diastole must by definition contain the iFR value and therefore should correlate very close with the iFR assessment. Preliminary unpublished data analyzing physiologic data in benchtop modeling from the VERIFY and CONTRAST studies suggest a very high correlation between iFR and diastolic Pd/Pa. This relationship strengthens when measurements are limited to 65% of diastole, hereby named the Diastolic hyperemia-Free Ratio (DFR). These data strongly suggest that DFR could be used as surrogate for iFR when iFR is not available and thus leverage the large clinical outcomes data for iFR in a new measure that is widely available to all standard coronary pressure wires. Although this preliminary data is strong, none of these measures where made prospectively in actual patients and the iFR was measured off simulated benchtop pressure waveform modeling. This study aims to perform a real-time correlation and agreement between iFR and DFR in patients with moderate coronary stenoses and indications for physiologic assessment.

Interventions

DEVICEphysiological assessment with Volcano Verrata pressure wire (iFR)

physiological assessment of the coronary lesion will be made with both iFR and dFR. all clinical decisions will be made based on the results of iFR

Sponsors

Boston Scientific Corporation
CollaboratorINDUSTRY
Washington University School of Medicine
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* Moderate Coronary lesion deemed to need iFR assessment - Angiographic severity of 40-70% that operator feels needs physiologic assessment * Age 18-90 year old * Single worst lesion per patient- Patients may have more than one lesion assessed but only 1 lesion will be evaluated per patient in this study

Exclusion criteria

* STEMI- Angiographic severity of 40-70% that operator feels needs physiologic assessment in setting of STEMI or 48hours within STEMI * Atrial fibrillation * Inability to provide informed consent- No surrogate or healthcare proxy will be allowed to consent for this study * Severe tortuosity- Vessel tortuosity that the operator feels would be difficult to pass 2 pressure wires down or where pseudo lesions may be formed. * Saphenous Vein Graft Lesion

Design outcomes

Primary

MeasureTime frameDescription
Correlation of iFR and DFRThe correlation between values will be the primary endpoint measured and occurs only during the index procedure.. DFR will be correlated, in VIVO, with the gold standard, diastolic coronary blood flow measurement, the instantaneous wave free ratio (iFR). Both DFR and iFR will be correlated simultaneously during the index procedure in patients with moderate coronary stenoses whom hemodynamic assessment was clinically indicated.
Agreement for treatment with iFRafter all subjects are enrolled the RedCap data will be evaluated. how many patients would be treated differently using iFR vs. DFR

Countries

United States

Outcome results

None listed