Skip to content

A Post-Market Clinical Evaluation of the Treatment of Femur Fractures With the Femoral Nail PF

A Post-Market Clinical Evaluation of the Treatment of Femur Fractures With the Femoral Nail Piriformis Fossa (PF) of the T2 Alpha Femur Antegrade GT/PF Nailing System

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04015154
Enrollment
53
Registered
2019-07-10
Start date
2019-09-12
Completion date
2025-09-15
Last updated
2026-04-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Femoral Fracture

Brief summary

This investigation is a prospective, multicenter clinical investigation. It is anticipated that a total of 50 subjects will be enrolled at up to 5 sites. Enrollment is estimated to commence in Q4 of 2018. Neither subjects nor investigators are blinded to treatment and the clinical investigation includes a historical control which will be compared to the Femoral Nail PF of the T2 Alpha Femur Antegrade GT/PF Nailing System. Total duration of enrollment, 12 month follow-up and analysis is expected to take 29 months. The clinical investigation has been designed to follow the surgeon's standard of care for femur fractured subjects, in addition to a 12 month follow-up visit. The primary endpoint of this clinical investigation is to confirm efficacy/performance at 12 months, as measured by the Lower Extremity Measure (LEM). Confirmation of efficacy/performance at 12 months will be based on an equal or greater (non-inferior) LEM score result of the Femoral Nail PF of the T2 Alpha Femur Antegrade GT/PF Nailing System compared to the T2 Femur benchmark literature.

Detailed description

The objective of this clinical investigation is to demonstrate the safety and efficacy/performance of the Femoral Nail PF of the T2 Alpha Femur Antegrade GT/PF Nailing System. Efficacy/performance of the procedure will be measured by an equal or greater (non-inferior) Lower Extremity Measure (LEM) score result of the Femoral Nail PF of the T2 Alpha Femur Antegrade GT/PF Nailing System compared to the T2 Femur benchmark literature at 12 months. In addition, demonstration of bone consolidation in correct alignment will be measured by Investigator assessment by 12 months. Safety of the Femoral Nail PF of the T2 Alpha Femur Antegrade GT/PF Nailing System will be demonstrated through reporting of device related intra-operative and post-operative Adverse Events/incidents by 12 months.

Interventions

DEVICEFemoral Nail PF of the T2 Alpha Femur Antegrade GT/PF Nailing System

The T2 Alpha Femur Antegrade GT / PF Nailing System is intended for temporary stabilization of bone segments or fragments until bone consolidation has been achieved.

Sponsors

Stryker Trauma and Extremities
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Subject is a male or non-pregnant female age 18 years or older at the time of surgery; * Subject is willing and able to give written informed consent and comply with the requirements of this Clinical Investigation Plan; * Subject is intended to be treated with the Femoral Nail PF of the T2 Alpha Femur Antegrade GT/PF Nailing System in accordance with the following legally cleared/ approved Indications for Use: Indications for Use: * Fixation of subtrochanteric, intertrochanteric, ipsilateral neck/shaft, comminuted proximal femoral shaft fractures * Femoral fixation required as a result of pathological disease * Temporary stabilization of fractures of the femoral shaft ranging from the femoral neck to the supracondylar regions of the femur * Open and closed femoral fractures * Pseudoarthrosis and correction osteotomy * Pathologic fractures, impending pathologic fractures and tumor resections * Ipsilateral femur fractures * Fractures proximal to a total knee arthroplasty * Nonunions and malunions * Fractures involving osteopenic and osteoporotic bone

Exclusion criteria

* Subject is currently enrolled in or plans to enroll in any concurrent drug and/or device clinical investigation that, in the opinion of the Investigator, may confound results; * Per the Investigator, the subject is in poor general health or undergoing any concurrent disease that would place the subject in excessive risk to surgery (i.e. significant circulatory problems, cardiac disease).

Design outcomes

Primary

MeasureTime frameDescription
Lower Extremity Measure (LEM)12 monthsThe primary endpoint of this clinical investigation is to confirm efficacy/performance at 12 months, as measured by the Lower Extremity Measure (LEM). Confirmation of efficacy/performance at 12 months will be based on an equal or greater (non-inferior) LEM score result of the Femoral Nail PF of the T2 Alpha Femur Antegrade GT/PF Nailing System compared to the T2 Femur benchmark literature

Secondary

MeasureTime frameDescription
Safety will be measured by capturing the incidence rate of device-related adverse events12 monthsIncidence of device-related adverse events will be monitored by 12 months through data collection and analyses.
Efficacy/Performance will be measured by demonstration of bone consolidation12 monthsBone consolidation will be assessed by 12 months as measured by Investigator assessment.

Countries

United States

Contacts

STUDY_DIRECTORRebecca Gibson

Stryker Trauma and Extremities

Outcome results

None listed