Skip to content

Influence of Respiratory Mechanics on Brain-specific Monitoring in Brain-injured Patients

Effects of Chest Wall and Lung Elastances on Intracranial Pressure and Brain-specific Multimodal Monitoring in Ventilated Brain Injured Patients

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04013698
Acronym
ABIVENT
Enrollment
0
Registered
2019-07-10
Start date
2019-08-01
Completion date
2020-11-02
Last updated
2021-06-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Brain Injuries

Keywords

ventilation, brain injuries, PEEP, esophageal pressure

Brief summary

Increase in intracranial pressure (ICP) could be associated with increase in positive end-expiratory pressure (PEEP) level. Data are however disparate and interactions between ventilation with high PEEP and intracranial circulation are still debated. Individual patient's chest wall elastance could have a key role in determining the effects of PEEP on ICP, since it dictates which proportion of the applied PEEP is transmitted to the pleural space, thus increasing central venous pressure (CVP) and reducing cerebral venous return. Measurement of esophageal pressure with a dedicated probe allows partitioning of respiratory system elastance into its lung and chest wall components, thus permitting to study this phenomenon. Multimodal intracranial monitoring permits to study the effects of PEEP on more advanced brain-specific indices such as brain tissue oxygen (PtiO2), cerebral microdialysis data, transcranial doppler ultrasound-derived flow measurements and automated pupillometry, besides ICP. This study aims to test the association between the ratio of chest wall to respiratory system elastance and PEEP-induced variations in ICP and brain-specific multimodal monitoring indices. This study will evaluate the relative role of other selected measures of respiratory mechanics, hemodynamic variables and intracranial compliance, in order to establish the role of individual respiratory mechanics in the interplay of physiological factors affecting the effects of positive pressure ventilation on the brain. Patients will undergo two periods of ventilation at two different levels of PEEP (5 and 15 cmH2O) in a randomized cross-over order. At the end of each period, cardiorespiratory clinical data, ICP and other advanced multimodal neuromonitoring data (brain tissue oxygen tension, cerebral microdyalisis analytes, transcranial doppler ultrasound and automated infrared pupillometry data) will be collected. Systematic respiratory mechanics assessment (including calculation of chest wall and lung elastances and estimation of the amount of recruitment versus overdistension due to PEEP by means of a single-breath derecruitment trial), echocardiography and arterial blood gas analysis will be performed.

Interventions

OTHERPEEP level 5 cmH2O

PEEP level set for 45 minutes

OTHERPEEP level 15 cmH2O

PEEP level set for 45 minutes

Sponsors

Piquilloud Imboden Lise
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
NONE

Intervention model description

Patients included will receive volume assist-control ventilation with PEEP set at 5 cmH2O and 15 cmH2O in a randomized order (crossover design). Each setting will be applied during 45 minutes.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Acute brain injury of any etiology requiring multimodal brain monitoring (intraparenchymal intracranial pressure, brain-tissue oxygen tension and cerebral microdialysis) * Controlled mechanical ventilation via endotracheal tube * Patient needing deep sedation

Exclusion criteria

* pregnancy * contraindications to nasogastric probe placement: basilar skull or significant naso-facial fractures, significant esophageal or gastric trauma or bleeding, previous esophageal surgery, significant bleeding diathesis (spontaneous aPTT \> 60 sec, PT \< 40%, INR \> 1.8, platelets \< 50000/mm3), known esophageal or gastric varices * decompressive craniectomy * intracranial pressure monitoring method other than intraparenchymal (e.g. connected to external ventricular drain) * severe relevant physiological instability contraindicating an increase in PEEP: severe baseline intracranial pressure elevation (\> 20 mmHg), severe hemodynamic instability (defined as norepinephrine requirements \> 0.5 μg/kg/min or cardiogenic shock, defined as any use of dobutamine) * conditions that interfere with accurate measurements of respiratory mechanics: bronchopleural fistula, pneumothorax. * Withhold of life-sustaining therapy for medical reasons

Design outcomes

Primary

MeasureTime frameDescription
Correlation between Ers/Ecw and change in ICP between the two PEEP levelsRecorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesRespiratory mechanics; intracranial pressure monitoring Ers/Ecw = chest wall to respiratory system elastances ratio; ICP = intracranial pressure

Secondary

MeasureTime frameDescription
Effect of the two different levels of PEEP on NPI.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesAutomated infrared pupillometry NPI = neurological pupil index PtiO2 = brain tissue oxygen tension; LPR = lactate/pyruvate ratio; NPI = neurological pupil index
Effect of the two different levels of PEEP on the following transcranial doppler ultrasound variables: MFV, DFV and PI.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesTranscranial doppler ultrasound MFV = mean flow velocity; DFV = diastolic flow velocity; PI = pulsatility index
Effect of the two different levels of PEEP on LPR.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesCerebral microdyalisis analytes LPR = lactate/pyruvate ratio
Effect of the two different levels of PEEP on PtiO2.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesBrain tissue oxygen tension. PtiO2 = brain tissue oxygen tension
Effect of the two different levels of PEEP on the following intravascular pressures: CVP, MAP, CPP.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesInvasive intravascular pressures. CVP = central venous pressure; MAP = mean arterial pressure; CPP = cerebral perfusion pressure
Effect of the two different levels of PEEP on the following echocardiographic measurements: LVOT VTI, CO.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesEchocardiography. LVOT VTI = left ventricle outflow tract velocity-time integral; CO = cardiac output (echocardiographically estimated).
Effect of the two different levels of PEEP on the dose of vasopressors/inotropes and volume of fluid boluses administered.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesAdministered drugs and fluids.
Correlation between Ers/Ecw and the following parameters at the two PEEP levels: LVOT VTI, CO; CVP, MAP, CPP; dose of vasopressors/inotropes and volume of fluid boluses administered.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesRespiratory mechanics; echocardiography; invasive intravascular pressures; administered drugs and fluids LVOT VTI = left ventricle outflow tract velocity-time integral; CO = cardiac output (echocardiographically estimated); CVP = central venous pressure; MAP = mean arterial pressure; CPP = cerebral perfusion pressure
Correlation between Pes_end-exp and the following parameters at the two PEEP levels: ICP, PtiO2, LPR, NPI, MFV, DFV, PI; CVP, MAP, CPP, LVOT VTI, CO, dose of vasopressors/inotropes and volume of fluid boluses administered.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesRespiratory mechanics; intracranial pressure monitoring, Brain tissue oxygen tension; cerebral microdyalisis analytes; automated infrared pupillometry; transcranial doppler ultrasound; Echocardiography; invasive intravascular pressures; administered drugs and fluids. ICP = intracranial pressure; PtiO2 = brain tissue oxygen tension; LPR = lactate/pyruvate ratio; NPI = neurological pupil index; MFV = mean flow velocity; DFV = diastolic flow velocity; PI = pulsatility index; CVP = central venous pressure; MAP = mean arterial pressure; CPP = cerebral perfusion pressure; LVOT VTI = left ventricle outflow tract velocity-time integral; CO = cardiac output (echocardiographically estimated)
Correlation between Ecw/Ers and the following neuromonitoring indices at the two PEEP levels: PtiO2, LPR, NPI; MFV, DFV and PI.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesRespiratory mechanics; brain tissue oxygen tension; cerebral microdyalisis analytes; automated infrared pupillometry; transcranial doppler ultrasound Ers/Ecw = chest wall to respiratory system elastances ratio; PtiO2 = brain tissue oxygen tension; LPR = lactate/pyruvate ratio; NPI = neurological pupil index; MFV = mean flow velocity; DFV = diastolic flow velocity; PI = pulsatility index
Correlation between Vd/Vt and the following parameters at the two PEEP levels: ICP, PtiO2, LPR, NPI, MFV, DFV, PI; CPPRecorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesRespiratory mechanics; intracranial pressure monitoring, brain tissue oxygen tension; cerebral microdyalisis analytes; automated infrared pupillometry; transcranial doppler ultrasound; invasive intravascular pressures. Vd/Vt = dead space to tidal volume ratio; ICP = intracranial pressure; PtiO2 = brain tissue oxygen tension; LPR = lactate/pyruvate ratio; NPI = neurological pupil index; MFV = mean flow velocity; DFV = diastolic flow velocity; PI = pulsatility index; CVP = central venous pressure; CPP = cerebral perfusion pressure
Correlation between baseline PI at transcranial doppler ultrasound and the following parameters at the two PEEP levels: ICP, PtiO2, LPR, NPI, MFV, DFV, PI; LVOT VTI, CO, MAP, CPP.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesIntracranial pressure monitoring, Brain tissue oxygen tension; cerebral microdyalisis analytes; automated infrared pupillometry; transcranial doppler ultrasound; Echocardiography; invasive intravascular pressures. PI = pulsatility index; ICP = intracranial pressure; PtiO2 = brain tissue oxygen tension; LPR = lactate/pyruvate ratio; NPI = neurological pupil index; MFV = mean flow velocity; DFV = diastolic flow velocity; PI = pulsatility index; LVOT VTI = left ventricle outflow tract velocity-time integral; CO = cardiac output (echocardiographically estimated); MAP = mean arterial pressure; CPP = cerebral perfusion pressure
Correlation between CVP and the following parameters at the two PEEP levels : ICP, PtiO2, LPR, NPI, MFV, DFV, PI; LVOT VTI, CO, MAP, CPP, dose of vasopressors/inotropes and volume of fluid boluses administered.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesIntracranial pressure monitoring, Brain tissue oxygen tension; cerebral microdyalisis analytes; automated infrared pupillometry; transcranial doppler ultrasound; Echocardiography; invasive intravascular pressures; administered drugs and fluids. CVP = central venous pressure; ICP = intracranial pressure; PtiO2 = brain tissue oxygen tension; LPR = lactate/pyruvate ratio; NPI = neurological pupil index; MFV = mean flow velocity; DFV = diastolic flow velocity; PI = pulsatility index; LVOT VTI = left ventricle outflow tract velocity-time integral; CO = cardiac output (echocardiographically estimated); MAP = mean arterial pressure; CPP = cerebral perfusion pressure
Correlation between LVOT VTI and the following parameters at the two PEEP levels: PtiO2, LPR, NPI, MFV, DFV, PI; MAP, CPP, dose of vasopressors/inotropes and volume of fluid boluses administered.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesBrain tissue oxygen tension; cerebral microdyalisis analytes; automated infrared pupillometry; transcranial doppler ultrasound; echocardiography, invasive intravascular pressures; administered drugs and fluids. LVOT VTI = left ventricle outflow tract velocity-time integral; PtiO2 = brain tissue oxygen tension; LPR = lactate/pyruvate ratio; NPI = neurological pupil index; MFV = mean flow velocity; DFV = diastolic flow velocity; PI = pulsatility index; MAP = mean arterial pressure; CPP = cerebral perfusion pressure
Correlation between PtiO2 and the following parameters at the two PEEP levels: ICP, MAP, dose of vasopressors/inotropes and volume of fluid boluses administered.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesIntracranial pressure monitoring, brain tissue oxygen tension; invasive intravascular pressures; administered drugs and fluids. PtiO2 = brain tissue oxygen tension; ICP = intracranial pressure; MAP = mean arterial pressure
Correlation between LPR and the following parameters at the two PEEP levels: ICP, MAP, dose of vasopressors/inotropes and volume of fluid boluses administered.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesIntracranial pressure monitoring, cerebral microdyalisis analytes; invasive intravascular pressures; administered drugs and fluids. LPR = lactate/pyruvate ratio; ICP = intracranial pressure; MAP = mean arterial pressure
Correlation between NPI and the following parameters at the two PEEP levels: ICP, MAP, dose of vasopressors/inotropes and volume of fluid boluses administered.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesIntracranial pressure monitoring, automated infrared pupillometry; invasive intravascular pressures; administered drugs and fluids. NPI = neurological pupil index; ICP = intracranial pressure; MAP = mean arterial pressure
Correlation between doppler indices (MFV, DFV and PI) and the following parameters at the two PEEP levels: ICP, MAP, dose of vasopressors/inotropes and volume of fluid boluses administered.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesIntracranial pressure monitoring, transcranial doppler ultrasound; invasive intravascular pressures; administered drugs and fluids. MFV = mean flow velocity; DFV = diastolic flow velocity; PI = pulsatility index; ICP = intracranial pressure; MAP = mean arterial pressure
Correlation between Rec/PEEPvol and the following parameters at the two PEEP levels: ICP, PtiO2, LPR, NPI, MFV, DFV, PI; CVP, MAP, CPP, LVOT VTI, CO, dose of vasopressors/inotropes and volume of fluid boluses administered.Recorded every minute during 10 minutes at the end of each 45-minute period (PEEP 5 and 15 cmH2O), 90 minutesRespiratory mechanics; intracranial pressure monitoring, Brain tissue oxygen tension; cerebral microdyalisis analytes; automated infrared pupillometry; transcranial doppler ultrasound; Echocardiography; invasive intravascular pressures; administered drugs and fluids. Rec/PEEPvol = recruited volume to PEEP-related volume ratio; ICP = intracranial pressure; PtiO2 = brain tissue oxygen tension; LPR = lactate/pyruvate ratio; NPI = neurological pupil index; MFV = mean flow velocity; DFV = diastolic flow velocity; PI = pulsatility index; CVP = central venous pressure; MAP = mean arterial pressure; CPP = cerebral perfusion pressure; LVOT VTI = left ventricle outflow tract velocity-time integral; CO = cardiac output (echocardiographically estimated)

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026