Skip to content

RESPOND EDGE Post Market Study

Repositionable Lotus Edge™ Valve System - Post Market Evaluation of Real World Clinical Outcomes

Status
Terminated
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04009720
Acronym
RESPOND EDGE
Enrollment
200
Registered
2019-07-05
Start date
2019-10-11
Completion date
2021-06-02
Last updated
2021-07-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Valve Stenosis

Brief summary

The purpose of the RESPOND EDGE post market study is to collect real world clinical and device performance outcomes data with the Lotus Edge™ Valve System used in routine clinical practice to demonstrate that the commercially available Lotus Edge Valve System is a safe and effective treatment for patients with severe calcific aortic stenosis.

Detailed description

The RESPOND EDGE study is a prospective, open label, single arm, multi-center, observational post market study designed to collect real world clinical and device performance outcomes data of the commercially available Lotus Edge Valve used in routine clinical practice for the treatment of severe calcific aortic stenosis. Approximately 200 real-world, consecutive subjects will be enrolled at up to 20 study centers. The study duration for each subject is expected to be approximately 2 years. Implanted subjects will be contacted for follow-up at 30 days, 1 and 2 years post index procedure. Subjects who are enrolled but not implanted with a Lotus Edge valve will be followed for safety through 30 days after the initial attempted index procedure. Collection of safety events will include any serious adverse event (SAE), serious adverse device effect (SADE), adverse device effect (ADE), unanticipated serious adverse device effect (USADE), and all Valve Academic Research Consortium (VARC) events regardless of seriousness and device relationship through 2 year follow-up.

Interventions

DEVICELotus Edge Device

The LOTUS Edge Valve System is indicated to improve aortic valve function for symptomatic subjects with severe calcific aortic stenosis (aortic valve area \[AVA\] \<1.0 cm2 or AVA index \<0.6 cm2/m2) who are at high risk for standard surgical valve replacement.

Sponsors

Boston Scientific Corporation
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Subjects will be evaluated for eligibility by the clinical center's heart team per the local standard of practice in accordance with the Directions for Use.

Design outcomes

Primary

MeasureTime frameDescription
All-cause mortality (Primary Safety Endpoint)30 daysThe primary safety endpoint is all-cause mortality at 30 days after the implant procedure. The primary safety endpoint will be evaluated on an intention to- treat (ITT) basis (all subjects enrolled, whether or not a Lotus Edge Valve is implanted).
Mean aortic valve pressure gradient (Primary Effectiveness Endpoint)Within 7 days after the index procedure (Pre-discharge)The primary effectiveness endpoint is the mean aortic valve pressure gradient (mmHg) at pre-discharge as determined by an independent core laboratory. The primary analysis set for the primary effectiveness endpoint is the implanted analysis set.

Countries

Denmark, Finland, France, Germany, Ireland, Italy, Netherlands, Sweden, United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026