Skip to content

Diagnostic Accuracy Of Forced Oscillation Technique To Detect Lung Function Anomalies

Diagnostic Accuracy Of Forced Oscillation Technique To Detect Lung Function Anomalies

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04006964
Enrollment
579
Registered
2019-07-05
Start date
2018-10-18
Completion date
2022-06-26
Last updated
2022-11-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Respiratory Disease

Brief summary

The diagnosis of a lung function anomaly requires the evaluation of pulmonary function by spirometry. However, some patients (e.g. children, elderly, or diseased individuals) may have difficulty performing the related forced maximal respiratory maneuver correctly. Forced Oscillation Technique (FOT) measures lung impedance during tidal breathing, requiring minimal patient cooperation. The purpose of this study is to establish the diagnostic accuracy of FOT parameters alone or in combination with lung volumes in detecting lung function anomalies as compared with spirometry and with the diagnosis made by the physician.

Detailed description

Purpose and Rationale The diagnosis of a lung function anomaly requires the evaluation of pulmonary function by spirometry. However, some patients (e.g. children, elderly, or diseased individuals) may have difficulty performing the related forced maximal respiratory maneuver correctly. FOT measures lung impedance during tidal breathing, requiring minimal patient cooperation. The within-breath calculation of impedance allows separating the contribution of inspiration and expiration to the measured parameters. The purpose of this study is to establish the diagnostic accuracy of FOT parameters alone or in combination with lung volumes in detecting lung function anomalies as compared with spirometry and with the diagnosis made by the physician. Objectives Primary: To compare the diagnostic accuracy of FOT with spirometry to detect a lung function anomaly (i.e. an obstructive and/or restrictive respiratory disease). Secondary: To compare the diagnostic accuracy of FOT with the final diagnosis made by the physician (i.e. the diagnosis based on current guidelines) to detect a lung function anomaly (i.e. an obstructive and/or restrictive respiratory disease). Study Design This will be a multi-center prospective study of consecutive subjects attending the pulmonary function test laboratory for pulmonary function tests (PFT) or randomly taken from the clinical site's records among those with symptoms with two separate study phases, an Identification Phase and a Validation Phase. Subjects will undergo the same study procedures in both phases. After signing the Informed Consent, a medical history will be obtained, a physical examination performed, and PFT (FOT, spirometry and, if required by the physician to reach a final diagnosis, additional lung function measurements) will be performed. Identification Phase: Subject data will be used to identify two separate rules based on abnormal lung volumes and impedance (FOT) parameters that will maximize the accuracy in identifying a lung function anomaly. For the primary objective, the reference test for the determination of such lung anomaly will be spirometry. For the secondary objective, the reference test for the determination of the presence of a lung function anomaly will be the final diagnosis made by the physician. Validation Phase: A separate and independent dataset of subjects will be used to test the accuracy of the rules identified from analysis of the Identification Phase in detecting a lung function anomaly. Study Duration Subject participation will be completed in 1 day. Study duration is expected to be 7 months

Interventions

DEVICEResmon PRO FULL v2

Measurement of lung impedance by the Forced Oscillation Technique

Sponsors

MGC Diagnostics
CollaboratorUNKNOWN
Restech Srl
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
3 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* All subjects ≥3 years old attending the pulmonary function laboratory with an order for PFT or * Subjects ≥3 years old randomly chosen from a database of subjects having respiratory symptoms at the time of inclusion into the database.

Exclusion criteria

\- Subjects unable to provide written Informed Consent (or not provided by the participant's parent/guardian) and Assent Form (where applicable).

Design outcomes

Primary

MeasureTime frameDescription
Decision rule that maximises sensitivity and specificity as compared with spirometry1 dayThis will be a rule to detect lung anomalies as compared with spirometry that will be identified and validated in two separate populations

Secondary

MeasureTime frameDescription
Decision rule that maximises sensitivity and specificity as compared with physician's diagnosis1 dayThis will be a rule to detect lung anomalies as compared with physician's final diagnosis that will be identified and validated in two separate populations

Countries

Italy, United States

Outcome results