The Influence of Different Preoperative Decision Schemes on the Visual Quality After Toric Intraocular Lens Implantation

The Influence of Different Preoperative Decision Schemes on the Visual Quality After Toric Intraocular Lens Implantation

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04006912
Enrollment
60
Registered
2019-07-05
Start date
2019-04-10
Completion date
2021-05-01
Last updated
2021-04-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Recruitment of Participants

Brief summary

To study the Influence of Different Preoperative Decision Schemes on the Visual Quality After Toric Intraocular Lens Implantation

Interventions

PROCEDUREphacoemulsification and Toric intraocular lens implantation

A clear corneal incision is made in a different position

Sponsors

Second Affiliated Hospital, School of Medicine, Zhejiang University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
55 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. Age-related cataract (age 55-80) 2. Corneal astigmatism is greater than 1.0D 3. Patients who are willing to implant Toric IOL

Exclusion criteria

1. Previous or present eye diseases, such as glaucoma, eye trauma, etc 2. High refractive error 3. Previous eye surgery 4. Irregular astigmatism of the cornea

Design outcomes

Primary

MeasureTime frameDescription
Actual residual astigmatism after surgery1 week postoperationThe actual residual astigmatism value after the operation is measured with the phoropter

Secondary

MeasureTime frameDescription
uncorrected distance visual acuity (UDVA)1 week postoperationuncorrected distance visual acuity (UDVA) is observed in each group
Theoretical residual astigmatism after surgery1 week postoperationThe theoretical residual astigmatism is obtained by TECNIS Toric online calculator
Postoperative Totic intraocular lens rotation angle1 week postoperationPostoperative Totic intraocular lens rotation angle is observed in each group
Postoperative astigmatism and astigmatism axial of cornea1 week postoperationPostoperative astigmatism and astigmatism axial of cornea are measured with Pentacam
Corneal Aberrations1 week postoperationCorneal aberrations are measured with OPD-Scan Ⅲ

Countries

China

Contacts

Primary ContactWen Xu, PHD
xuwen2003@zju.edu.cn+86 571 87783897

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 14, 2026