NOTAL-OCT V.2.5 vs Commercial OCT in AMD Patients

Comparison Between Retinal Images Captured by NOTAL-OCT V2.5 and Zeiss Cirrus / Heidelberg Spectralis SD OCT - Study Protocol

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03969303
Enrollment
287
Registered
2019-05-31
Start date
2018-10-20
Completion date
2019-10-04
Last updated
2020-11-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

AMD - Age-Related Macular Degeneration, Diabetic Macular Edema

Brief summary

Primary objective: To evaluate the level of agreement between the NOTAL-OCT V2.5 and a commercial OCT in the presence of fluid as identified in the OCT images, in the central 10 degrees of the macula in AMD (Age-related Macular Degeneration) patients. Secondary objectives: 1. To evaluate the level of agreement between the NOTAL-OCT V2.5 and a commercial OCT in the presence of fluid as identified in the OCT images, in the central 10 degrees of the macula in DME (Diabetic Macular Edema) patients. 2. To evaluate patient experience when self-operating the Notal-OCT V2.5.

Detailed description

To evaluate the sensitivity and specificity regarding the presence and absence of fluid on OCT images of AMD patients. OCT images from the central 10 degrees of the macula in AMD patients will be obtained using the NOTAL OCT v.2.5 and a commercial OCT device (Zeiss Cirrus / Heidlberg SPECTRALIS). These images will be evaluated for the presence/absence of fluid in the images by a human grader. The sensitivity and specificity will be determined by comparison of the presence/absence of fluid in the NOTAL OCT v2.5 images with the presence/absence of fluid in the commercial OCT images. To evaluate the sensitivity and specificity regarding the presence and absence of fluid on OCT images of DME patients. OCT images from the central 10 degrees of the macula in DME patients will be obtained using the NOTAL OCT v.2.5 and a commercial OCT device (Zeiss Cirrus / Heidlberg SPECTRALIS). These images will be evaluated for the presence/absence of fluid in the images by a human grader. The sensitivity and specificity will be determined by comparison of the presence/absence of fluid in the NOTAL OCT v2.5 images with the presence/absence of fluid in the commercial OCT images. Patients will complete a questionnaire regarding the usability of the NOTAL-OCT v.2.5 device

Interventions

DEVICENotal Vision Optical Coherence Tomography Device Version 2.5 (NOTAL-OCT V2.5)

OCT SCAN

Sponsors

Elman Retina Group
CollaboratorOTHER
Notal Vision Ltd.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Ability and willingness to give informed consent (IC) * 18 years of age or older * Diagnosis of AMD (age-related macular degeneration) and/or DME (diabetic macular edema) in the study eye as confirmed by the investigator and recorded in the patient's clinical record * Ability to undergo OCT (optical coherence tomography) testing * Visual acuity of 20/400 Snellen (6/120) or better in the study eye

Exclusion criteria

\- Any ophthalmic or systemic condition that in the opinion of the investigator would preclude the patient from participating in the study.

Design outcomes

Primary

MeasureTime frameDescription
Comparison of presence/absence of fluid on OCT images from NOTAL-OCT v.2.5 device with a commercial OCT device, in AMD (Age-related Macular Degeneration) patientsless than an hourTo evaluate the sensitivity and specificity regarding the presence and absence of fluid on OCT images of AMD patients. OCT images from the central 10 degrees of the macula in AMD patients will be obtained using the NOTAL OCT v.2.5 and a commercial OCT device (Zeiss Cirrus / Heidlberg SPECTRALIS). These images will be evaluated for the presence/absence of fluid in the images by a human grader. The sensitivity and specificity will be determined by comparison of the presence/absence of fluid in the NOTAL OCT v2.5 images with the presence/absence of fluid in the commercial OCT images.

Secondary

MeasureTime frameDescription
Comparison of presence/absence of fluid on OCT images from NOTAL-OCT v.2.5 device with a commercial OCT device, in DR (Diabetic Retinopathy) patientsless then an hourTo evaluate the sensitivity and specificity regarding the presence and absence of fluid on OCT images of DR patients. OCT images from the central 10 degrees of the macula in DR patients will be obtained using the NOTAL OCT v.2.5 and a commercial OCT device (Zeiss Cirrus / Heidlberg SPECTRALIS). These images will be evaluated for the presence/absence of fluid in the images by a human grader. The sensitivity and specificity will be determined by comparison of the presence/absence of fluid in the NOTAL OCT v2.5 images with the presence/absence of fluid in the commercial OCT images.
Patient experience using the NOTAL-OCT v.2.5 deviceless than an hourPatients will complete a questionnaire with 13 statements or questions regarding the usability of the NOTAL-OCT v.2.5 device. For the first 10 statements, patients are asked to specify a level of agreement to the statement. The scale is named Level of Agreement and ranges from 1 = strongly agree, to 5 = strongly disagree. A patient's indicating a value of 1 is considered to be a better outcome. The remaining 3 questions are free-form.