Copd, Pulmonary Disease
Conditions
Keywords
COPD
Brief summary
The objective is to verify that there is a decrease in the pulsed oxygen saturation with the digital sensor. That is, the drop in oxygen saturation in COPD patients during inhalation is real and not due to an artifact of the measuring tool, because oximeters need a quality pulsatile signal to properly measure oxygen saturation
Interventions
Measurements during deep inspiration of oxygen saturation with pulse oximeter and finger pressure with pressure cuff
Sponsors
Study design
Intervention model description
half healthy subject, half COPD patients
Eligibility
Inclusion criteria
healthy arm Inclusion Criteria: * Healthy adults volunteers are recruited from students with normal lung function.
Exclusion criteria
* abnormal lung function COPD Arm Inclusion Criteria: * Adults with Chronic Obstructive pulmonary disease
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| drop in oxygen saturation during deep inspiration in COPD | from the intervention to 3 minutes after the start of the intervention | saturation is measured in percentage (SPO2) |
Countries
Belgium