Skip to content

Design and Application of Airborne Visual Real-time Evaluation System for Air Medical Rescue

Design and Application of Airborne Visual Real-time Evaluation System for Air Medical Rescue

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03958682
Enrollment
100
Registered
2019-05-22
Start date
2018-12-05
Completion date
2021-12-31
Last updated
2019-05-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Medical Emergencies

Keywords

air medical rescue, satellite information transmission, Augmented Reality

Brief summary

This study intends to use AR (Augmented Reality) smart wearing equipment combined with 4G + satellite information transmission system to achieve two-way real-time information transmission in air-to-ground medical rescue.

Detailed description

Investigators are going to add a pair of wearable smart glasses with AR function to the original flight helmet .During the rescue, the doctors are asked to wear the special helmet, through the device's camera system and headset, investigators can obtain graphics and sound of the helicopter cabin .At the same time, it also receives the historical data of patients and real-time diagnosis as well as rescue guidance from the ground medical institutions. In short ,it can not only transmit the patient's information in the cabin to the ground medical institutions in real time, but also transmit the rescue plan of the ground medical experts to the rescue helicopter in real time to ensure the safety of patients in transit ,which will save the time for medical staff to hand over after landing and reduce errors. At present, most of the airborne information exchange systems in air medical rescue in China focus on the internal use of the army, which are incompatible with the medical information systems of most hospitals on the ground. Moreover, these systems can only achieve limited information transmission, and can not delivery rescue scene images in real time. Civil air medical rescue conditions are relatively backward, most of them rely on 2G/3G/4G mobile communication technology, which can lead to failure in case of bad weather or sudden major disasters, and bring great security risks to patients in air medical rescue. If the airborne visual real-time evaluation system can be successfully completed, it will be popularized and applied in Chinese airborne first aid alliance, and eventually a standardized airborne medical rescue information management system will be formed. Furthermore, a three-dimensional rescue system for civil airborne medical rescue will be built to reduce the potential safety hazards of patients in airborne medical rescue, and to enhance the rapid response ability and organization of medical institutions.

Interventions

DEVICEAR smart wearing equipment combined with 4G + satellite information transmission system

We are going to add a pair of wearable smart glasses with AR function to the original flight helmet .During the rescue, the doctor is asked to wear the special helmet , through the device's camera system and headset, we can obtain graphics and sound of the helicopter cabin .At the same time, it also receives the historical data of patients and real-time diagnosis as well as rescue guidance from the ground medical institutions. It can not only transmit the patient's information in the cabin to the ground medical institutions in real time, but also transmit the rescue plan of the ground medical experts to the rescue helicopter in real time to ensure the safety of patients in transit ,which will save the time for medical staff to hand over after landing and reduce errors.

Sponsors

Second Affiliated Hospital, School of Medicine, Zhejiang University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Critically ill patients who require air transportation support; * Patients informed consent and sign the informed consent form

Exclusion criteria

* None

Design outcomes

Primary

MeasureTime frameDescription
percentage of data correctly transmittedeach rescue, for 1 yearRecord the data sent from the ground hospital or helicopter cabin and data received in the helicopter cabin or ground hospital. Calculate the percentage of correctly transmitted data.
Time-consumingeach rescue, for 1 yearThe time required for data transmission

Secondary

MeasureTime frameDescription
Satisfaction indexeach rescue, for 1 yearDesign a questionnaire to evaluate the satisfaction of using the device by doctors and nurses. The questionnaire consists five items rating from 1 to 5. 1 represents extremely not satisfied, 5 represents very satisfied. The highest score is 25.

Countries

China

Contacts

Primary ContactXiuqin Feng
fengxiuqin@zju.edu.cn13757119151

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026