Validation of Two Wrist-worn Devices for the Assessment of Energy Expenditure in Cardiac Patients.

Validation of Two Wrist-worn Devices for the Assessment of Energy Expenditure in Patients With Chronic Heart Failure and Coronary Artery Disease.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03951740
Enrollment
39
Registered
2019-05-15
Start date
2017-10-11
Completion date
2018-06-27
Last updated
2019-05-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease, Heart Failure With Reduced Ejection Fraction

Keywords

Fitbit Charge 2, Mio Slice, Validation study, Energy expenditure

Brief summary

Improving physical activity is a core component of secondary prevention and cardiac (tele)rehabilitation. Commercially available activity trackers are frequently used to monitor and promote physical activity in cardiac patients. However studies on the validity of these devices in cardiac patients are scarce. The aim of this study is to determine the accuracy and responsiveness of two wrist-worn activity trackers, Fitbit Charge 2 (FC2) and Mio Slice (MS), for the assessment of energy expenditure (EE) in cardiac patients.

Detailed description

Introduction Improving physical activity is a core component of secondary prevention and cardiac (tele)rehabilitation. Commercially available activity trackers are frequently used to monitor and promote physical activity in cardiac patients. However studies on the validity of these devices in cardiac patients are scarce. The aim of this study is to determine the accuracy and responsiveness of two wrist-worn activity trackers, Fitbit Charge 2 (FC2) and Mio Slice (MS), for the assessment of energy expenditure (EE) in cardiac patients. Methods Eligible patients are recruited by their cardiologist in the outpatient cardiology clinic. If a patient is willing to participate, he/she visits the Máxima Medical Centre once, to perform the study measurements. EE assessed by both activity trackers is compared with indirect calorimetry (Oxycon Mobile) during a laboratory activity protocol consisting of 14 low-to-moderate intensity activities. The duration of the activities varies between 1 to 5 minutes, while total duration of the protocol is 39 minutes (resting time excluded) Two groups are assessed: patients with stable coronary artery disease (CAD) and patients with heart failure with reduced ejection fraction (HFrEF). Sample size calculation To achieve 80% power to detect an intraclass correlation coefficient (ICC) of 0.75 (excellent agreement) under the alternative hypothesis that the ICC is 0.35 (poor agreement), a sample size of 19 subjects per study group (i.e. CAD and HFrEF) is calculated. Statistical analysis Accuracy of FC2 and MS will be assessed by calculating mean EE and mean differences in EE compared to the criterion measure (Oxycon Mobile). To identify if agreement is between reasonable limits one-sample T-tests will be performed using mean differences. In addition, Bland-Altman plots will be created to illustrate the level of agreement with mean bias and 95% upper and lower limits of agreement (LoA). Moreover ICC using two-way mixed models with absolute agreement will used. Responsiveness of FC2 and MS will be assessed by using a paired T-test during walking and cycling at different intensities. Significance level will be set at p\<0.05 for all analyses.

Interventions

Energy expenditure (kcal) assessed by this activity tracker will be compared with indirect calorimetry (Oxycon Mobile) during a laboratory activity protocol. Two groups will be assessed: patients with stable coronary artery disease (CAD) and patients with heart failure with reduced ejection fraction (HFrEF).

DEVICEMio Slice

Energy expenditure (kcal) assessed by this activity tracker will be compared with indirect calorimetry (Oxycon Mobile) during a laboratory activity protocol. Two groups will be assessed: patients with stable coronary artery disease (CAD) and patients with heart failure with reduced ejection fraction (HFrEF).

DEVICEOxycon Mobile

The Oxycon Mobile will be used as the reference method/golden standard to calculate energy expenditure (kcal). This device (consisting of a face mask and gas analyzer unit) will be worn during the entire laboratory activity protocol. Two groups will be assessed: patients with stable coronary artery disease (CAD) and patients with heart failure with reduced ejection fraction (HFrEF).

Sponsors

Maxima Medical Center
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Masking description

Masking not applicable

Intervention model description

This is a single-center validation study with a comparative design. Accuracy and responsiveness of two wrist-worn activity trackers will be assessed. 39 patients (19 with coronary artery disease with preserved left ventricular ejection fraction and 19 with heart failure with reduced left ventricular ejection fraction) will be included.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

heart failure patients: * Patients with heart failure with reduced ejection fraction (LVEF \< 40%) due to ischemic or dilating cardiomyopathy * New York Heart Association Class II to III * Speaking Dutch language

Exclusion criteria

heart failure patients: * Hemodynamically significant valvular disease * Atrial fibrillation * Peripheral vascular, neurological and orthopaedic conditions impairing exercise capacity * Severe psychological or cognitive impairments Inclusion criteria patients with coronary artery disease * Stable coronary artery disease regardless of intervention (PCI or CABG) * Speaking Dutch language

Design outcomes

Primary

MeasureTime frameDescription
AgreementDuring a laboratory protocol consisting of 14 low-to-moderate intensity activities (39 minutes in total, resting time excluded)Energy expenditure (measured in kcal) will be extracted from both activity trackers for each separate activity of the protocol as well as for the total protocol. Breath-by-breath oxygen uptake (VO2) and carbon dioxide production (VCO2) will be measured during the entire length of the protocol using the Oxycon Mobile (reference method). By using the Weir equation, energy expenditure (kcal) will be calculated from VO2 and VCO2. Agreement of energy expenditure measurement is assessed by using mean differences in energy expenditure measured by the activity trackers versus the Oxycon Mobile and by calculating an intra-class correlation coefficient.

Secondary

MeasureTime frameDescription
ResponsivenessCycling at three different intensities (3 minutes at each intensity) and treadmill walking at three different intensities (3 minutes at each intensity))Responsiveness (i.e. ability to detect within-patients changes of energy expenditure measurement over time) of the activity trackers will be calculated by using a paired T-test during walking and cycling at different intensities.

Countries

Netherlands