The BLIMP Balloon in Coronary Interventions

A Prospective, Multi-Center Registry, Randomized Trial for Evaluation of Effectiveness of the Blimp Scoring Balloon in Lesions Not Crossable With Conventional Balloon or Microcatheter.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03947398
Enrollment
128
Registered
2019-05-13
Start date
2019-03-28
Completion date
2021-03-28
Last updated
2023-01-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chronic Total Occlusion of Coronary Artery, Percutaneous Coronary Intervention

Brief summary

The purpose of this study is to investigate the effectivness of the Blimp Scoring balloon compared to current available CTO balloon catheters.

Detailed description

For this study two case situations are being considered. 6.1.1 Case Situation A Guidewire crossed the lesion, micro catheter does not cross Case situation A is the circumstansis where a physician is using a guidewire in combination with a micro catheter. When in such case the guidewire is crossing at a certain moment of the procedure and the micro catheter not a balloon crossing attempt is one of the current common options as next step. For the study the physician will go through following steps 1. select alternating in 50% of these cases his current first choice regular balloon (≤ 1.5 (mm) OD) and in the other 50% of cases the Blimp. 2. If first choice regular balloon does not cross select the Blimp and if the Blimp has been first choice select regular first choice balloon. 3. If step 2 is not succesfull take a 6F guide extension and repeat sequence of step 1&2. 4. If step 3 is also not succesfull report how else succeeded (e.g. tonus, balloon rupture, carlino, rotablation, subintimal cross…) or not. See also appendix I for a flow chart case situation A. 6.1.2 Case Situation B Small balloon catheter (≤ 1.5 (mm)) needed for procedure- no micro catheter used. Case situation B is the circumstansis where a physician is in the stage of a procedure where he/ she would normally want to select a small balloon catheter ((≤ 1.5 (mm)) to cross an occluded or subtotlal stenotic segment of the coronary artery. When in such case the balloon catheter is not crossing the selection/ attempt with another balloon is one of the current common options as next step. For the study the physician will go through following steps 1. select alternating in 50% of these cases his current first choice regular balloon (≤ 1.5 (mm) OD) and in the other 50% of cases the Blimp. 2. If first choice regular balloon does not cross select the Blimp and if the Blimp has been first choice select regular first choice balloon. 3. If step 2 is not succesfull take a 6F guide extension and repeat sequence of step 1&2. 4. If step 3 is also not succesfull report how else succeeded (e.g. tonus, balloon rupture, carlino, rotablation, subintimal cross…) or not.See also appendix I for a flow chart of case situation B. 6.1.3 Use of the Blimp during the study The Blimp should be used conform its Instruction For Use (IFU). Following techniques can be attemted to cross the lesion. 1. Regular balloon crossing of lesion if no significant resistance is felt. 2. Application of distal force/ push to the tip of Blimp against the proximal cap of the occlusion/subtotal lesion for 5-10 seconds to allow cap penetration due to spring principle of Blimp shaft. 3. If no progressing in step 2 keep distal force/ push to the tip of the Blimp and inflate to 25-30 ATM to attempt wedging/ scoring of the proximal cap. 4. Repeat step 2&3 up to three times to see if proximal cap/ crossing progression is made. 5. If after multiple attemps of step 2&3 no progression is demonstrated it should be concluded that the Blimp was unsuccesfull in crossing. 6.1.4 Study population and number of subjects A total 128 patients which are being targeted for percutaneous coronary intervention are selected for this study. Pased on power calculations, 128 patiants are sufficient to demonstrate a statistical significant difference in outcome (P\<0.05) with 80% power. 6.1.5 Inclusion/exclusion criteria Patients will be enrolled if they require percutaneous coronary intervention (PCI) procedure and 1. During the case a micro catheter is being used which is not able to cross after crossing of the guidewire (case situation A). 2. During the case a small balloon catheter (≤ 1.5 (mm) OD) is being used and is not able to cross the target lesion (case situation B) . Patients which under normal conditions would be excluded for a PCI procedure by the hospital will be excluded from the study. 6.1.6 Rational and justification of chosen study design The Blimp is intended for balloon dilatation of a coronary artery subtotal lesion/occlusions. Due to its * very small profile * high rated burst pressure and * guidewire scoring element over the balloon the device has several features which can improve the crossabiltiy and initial dilation of severe occluded vessels. The study has been designed such to investigate in an objective and controlled manner if the Blimp Scoring balloon is providing an improved procedural success rate in these matters.

Interventions

DEVICEBLIMP balloon

Using BLIMP balloon to cross lesion

DEVICELow profile balloon

using low profile balloon to cross lesion

Sponsors

Ziekenhuis Oost-Limburg
CollaboratorOTHER
AZ Sint-Jan AV
CollaboratorOTHER
CHU de Charleroi
CollaboratorOTHER
Jolimont, La Louviere
CollaboratorUNKNOWN
Centre Hospitalier Universitaire Saint Pierre
CollaboratorOTHER
Onze Lieve Vrouwziekenhuis Aalst
CollaboratorOTHER
Centre Hospitalier Universitaire UCLouvain Namur
CollaboratorOTHER
University Ghent
CollaboratorOTHER
University Hospital, Antwerp
CollaboratorOTHER
Centre Hospitalier du Luxembourg
CollaboratorOTHER
Universitaire Ziekenhuizen KU Leuven
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Severe coronary lesion where microcatheter or dilatation balloon does not cross

Exclusion criteria

* none

Design outcomes

Primary

MeasureTime frameDescription
Successful crossing through lesion and dilatation with BLIMP or low profile balloonThe primary outcome is a procedural assessmentpassing of BLIMP or low profile balloon through lesion. If device passess it will be determined a successful outcome, if it does not pass, an unsuccesful outcome.

Countries

Belgium

Outcome results

None listed