Effect of Thoracic Diameter and Food Intake on Fibroscan® Results

Effect of Thoracic Diameter and Food Intake on Fibroscan® Results: Comparison of the S - and M-probes

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03947359
Acronym
FS
Enrollment
53
Registered
2019-05-13
Start date
2019-06-01
Completion date
2020-12-31
Last updated
2021-02-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Liver Stiffness

Brief summary

The study aims to deliver scientific data regarding the accuracy of the two different-sized Fibroscan® probes on patients with different thoracic diameter to gain more knowledge of the handling and measuring quality of the Fibroscan® as a diagnostic device and also to see if one probe is enough to measure a wider spectrum of patients leading to cost reduction for equipment such as additional probes. Furthermore the study aims to analyze the effect of food intake on liver-stiffness measurements with the S-probe on children to shorten fasting periods. It is hypothesized that the fasting periods before a Fibroscan® measurement may be shortened, which is of special importance in smaller children.

Detailed description

The Fibroscan® (Echosens, France) is an ultrasound-based, non-invasive and non-painful diagnostic device which also has no complications and can be repeated easily to measure liver-stiffness by transient elastography. The company's device was first released and put on the market in 2003. The device can measure liver stiffness and liver fat content (controlled attenuation parameter CAP). It is used for the identification and graduation of liver pathologies such as fibrosis and cirrhosis and it can be used on adults and children alike. Therefore patients with chronic liver diseases such as hepatitis C, hepatitis B, alcoholic liver disease as well as metabolic steatohepatitis and different biliary diseases can be examined with it. Currently the standard procedure for grading fibrosis and cirrhosis still is the liver biopsy, however studies have compared the two procedures in context with different liver conditions like non-alcoholic fatty liver disease or hepatitis C and partially demonstrated that in terms of measuring liver-stiffness the Fibroscan® can rival the liver biopsy. Usually the Fibroscan® measurements are performed using different probes that vary in frequency and penetration depth depending on the thoracic diameter of the patient. These probes are then applied in an intercostal space on the right side on the level of the liver. The company Echosens that is producing the currently used model of the Fibroscan® alongside its different-sized probes claims that their S-sized probe is to be used for patients with a thoracic diameter below 75 cm and that their M-sized probe for patients above 75 cm diameter because otherwise the results would not be accurate. The company claims that using the M-sized probe on a patient with a thoracic diameter below 75 cm would cause wrong measurements. However, there is no data or studies that actually have compared the S- and the M- probe to each other and therefore the accuracy of the statement from Echosens is scientifically yet to be confirmed. So far only data on comparison of the M and XL-probe have been published. Furthermore, food intake seems to impact on Fibroscan® -measurements. It has been already proven in past studies that food intake indeed has an effect on liver-stiffness and therefore influences the quality of Fibroscan® -measurements. All these studies revealed that it is the best to measure the patients while in a fasting condition for several hours. However, these studies all were performed on adults with different kinds of liver-diseases using the M-probe. So far, no data on the impact of food intake on measurements with the S-probe have been published. Since it is to be expected that because of its attributes transient elastography will gain even more importance as a diagnostic device in the future, it is very significant to produce as much of valid data as possible.

Interventions

DIAGNOSTIC_TESTFibroscan Touch 502 M probe

Measurement of liver stiffness

DIAGNOSTIC_TESTFibroscan Touch 502 S probe

Measurement of liver stiffness

Sponsors

Medical University of Graz
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Intervention model description

Healthy volunteers

Eligibility

Sex/Gender
ALL
Age
9 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

Age \> 18 for the adult Population Age 11-18 for the paediatric population Informed consent No history of liver disease Thoracic diameter \>45 cm

Exclusion criteria

Acute or chronic liver disease Any other disease or circumstance that may impact on the result of the study

Design outcomes

Primary

MeasureTime frameDescription
Liver stiffnessbaselineComparison of liver stiffness measurements at baseline with M- and S- probe

Secondary

MeasureTime frameDescription
Liver stiffness120 minutesMeasurement of liver stiffness measurements with M- probe after a standardized meal
Liver fat contentbaselineControlled attenuation parameter measured with M probe

Countries

Austria

Outcome results

None listed