Evaluation of a New Eye-specific Multivitamin Formula in Participants at Risk of Age-related Macular Degeneration (AMD)

Clinical Evaluation of a Micronized, Lipid-based Carotenoid Supplement in Eyes With Retinal Drusen

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03946085
Acronym
AMD
Enrollment
79
Registered
2019-05-10
Start date
2018-01-19
Completion date
2018-11-01
Last updated
2019-05-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Age-related Macular Degeneration, Macular Degeneration, Retinal Drusen

Keywords

Lumega-Z, Carotenoid supplement

Brief summary

The aim of this study is to evaluate the clinical benefits in visual function from dietary supplementation of the Lumega-Z carotenoid liquid-supplement in participants with drusen and at risk of AMD. The effects of Lumega-Z supplementation will be compared to an active comparator, the AREDS2 multivitamin.

Interventions

DIETARY_SUPPLEMENTLumega-Z

A specially-formulated carotenoid supplement formula that utilizes a micronized, lipid-based liquid form of delivery.

DIETARY_SUPPLEMENTAREDS2

A commercially-available multivitamin soft gel formula.

Sponsors

Western University of Health Sciences
CollaboratorOTHER
Eye Clinic of Austin
CollaboratorOTHER
Guardion Health Sciences, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
SINGLE (Subject)

Intervention model description

Parallel treatment group participants will be randomly assigned either the experimental intervention, Lumega-Z, or the AREDS2 supplement. An observational, control group will be included for further comparison.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

\- patients with retinal drusen (as determined by clinical fundus photography examination) and dark adaptation recovery time of 6 to 10 minutes.

Exclusion criteria

* presence of congenital retinal pathologies that may impact data collection * prior history of retinal-detachment or vitreo-retinal surgeries with any complications * best-corrected visual acuity of 20/40 or worse

Design outcomes

Primary

MeasureTime frameDescription
Mean Changes in Visual Acuity (VA)Baseline, 3-months, and 6-monthsRepeated measures were obtained using the Early Treatment Diabetic Retinopathy Study (ETDRS) chart-based acuity exam. The ETDRS chart allows a geometric quantification the participant's visual acuity threshold for images under daylight-conditions of black & white contrast. Participant scores were reported as Logarithm of the Minimum Angle of Resolution (LogMAR) units; a more accurate, standardized value equated from the similar acuity charts. Per the clinical evaluation protocol, LogMAR scores of 0.00 - 0.20 are considered good/normal visual acuity scores; total range of 0.00 - 1.00. Scores are reported as averaged values, according to each respective group of participants and time-point from which the measurements were collected (i.e. baseline, 3-months, etc...). Exclusion criteria included LogMAR scores greater than, or equal to, 0.30 (equivalent to visual acuity of 20/40 or worse).
Mean Changes in Contrast Sensitivity (CS)Baseline, 3-months, and 6-monthsContrast Sensitivity Function (CSF) was measured using the CSV-1000E device and measurements were analyzed as logCS units (logarithm of Contrast Sensitivity). The device measures both high- and low-contrast sensitivity (participant's ability to discern size and contrast) within a detection task, and reported as a response-curve. The curve compares the lowest contrast-level for a specific-sized target (across four spatial frequencies; per the manufacturer). Thus, the logCS unit of Contrast Sensitivity, is inversely related to the target's contrast level (displayed by the device). All measurements are reported as averaged values within each group, according to their respective time-frame within the study. Normal LogCS scores for adults aged 50-75 years old, in ascending order of spatial frequency (3, 6, 12, and 18), are (1.56 +/- 0.15), (1.80 +/- 0.165), (1.50 +/- 0.15), and (0.93 +/- 0.25). Values were utilized for scale, as recommended by the manufacturer/protocol.
Mean Changes in Dark Adaptation Recovery (DAR)Baseline, 3-months, and 6-monthsDAR measurements were collected using the AdaptDx adaptometer, to identify the participant's impaired dark adaptation threshold value (in response to low-light condition sensitivity). The device's software reported each patient's sensitivity-value over units of time (minutes), and were recorded as units of Rod Intercept Time. Similarly, measurements reported from each group were an averaged value amongst participant groups at each time-point of collection. According to the manufacturing protocol, a Rod Intercept Time of 6.5 minutes was determined to be the cut-off value for part of the inclusion criteria into treatment groups. Previous studies have demonstrated that scores equal to, or greater than, 6.5 minutes are indicative of early-AMD, and those less than 6.5 minutes are considered normal Rod Intercept values.
Mean Changes in Macular Pigment Optical Density (MPOD)Baseline, 3-months, and 6-monthsMPOD levels were measured by heterochromatic flicker photometry, using the MapCatSF device. MPOD (Macular Pigment Optical Density) measurements represent the level of light absorption by the macular pigment within the central retina, and provide measurements related to macular carotenoid densities. Measurements were reported as LogMAR units (total range of 0.00 to 1.00), as determined by the manufacture software program. Averaged values were reported within each group, at each time-point of collection. MPOD values between 0.22 - 0.44 logMAR units have been determined to be middle-range MPOD levels; average value in the USA approximately 0.35. Measurements between (0.0 - 0.21) were considered low-MPOD levels, and those between (0.45 - 1.0) were considered high-MPOD levels. All ranged-scores were obtained by recommendation from the manufacturer.

Countries

United States

Outcome results

None listed