Skip to content

A Trial to Evaluate the Safety and Efficacy of a Fully Degradable Ventricular Septal Defect (VSD) Closure

Chinese Academy of Medical Sciences, Fuwai Hospital

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03941691
Enrollment
108
Registered
2019-05-08
Start date
2019-04-11
Completion date
2021-04-20
Last updated
2019-05-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ventricular Septal Defect

Keywords

VSD, Ventriculai Septal Defects, amplatzer

Brief summary

The purpose of this clinical trial is to verify the safety and effectiveness of the Fully Absorbable VSD Occlusion System and VSD Occlusion System produced by Shanghai shape memory alloy materials co., LTD. Clinical trials are designed as prospective, multicenter, randomized controlled, noninferiority clinical trials. Prospective randomized multicenter trial involving about 108 subjects will be enrolled in 4 centers. Patients will be randomized to two groups in equal proportion (54 in each). The success rate of occlusion at 6 months after operation is the main evaluation index in this clinical trial.

Detailed description

1. This is a prospective, multicenter, randomized and noninferiority clinical trial, which is designed to compare the effectiveness and safety with the fully absorbable ventricular septal defect (VSD) occlusion system and VSD occlusion system produced by Shanghai shape memory alloy materials co., LTD. 2. This trial will recruit about 108 subjects from 4 centers. Patients will be randomized to two groups in equal proportion (54 in each). The proposal recruiting period is 12 months and the follow-up will be performed at 1 month, 3 months and 6 months after surgery.

Interventions

DEVICEFully Absorbable VSD Occlusion System

Under echocardiography guided treatment of VSD with a novel fully degradable clolsure system

DEVICEVSD Occluder

Under echocardiography guided treatment of VSD with commercially available occluder.

Sponsors

Shanghai Shape Memory Alloy Co., Ltd.
CollaboratorUNKNOWN
Chinese Academy of Medical Sciences, Fuwai Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
1 Years to 60 Years
Healthy volunteers
No

Inclusion criteria

1. Subjects and/or their legal guardians will be informed of the nature of this study and agree to participate in this clinical trial in accordance with all terms of this study.Signed the informed consent approved by the ethics committee, agreed to accept the postoperative treatment program, and completed the follow-up and related examinations as required by the follow-up; 2. Aged from 1 to 60 years old, weight more than 10 kg, male or non-pregnant women; 3. VSD effective shunt ≥3mm, ≤14mm; 4. Distance between the edge of defect and the right aortic valve is more than 3mm, no aortic valve prolapse or moderate aortic regurgitation.

Exclusion criteria

1. Irreversible pulmonary vascular disease;Severe pulmonary hypertension with bidirectional shunt; 2. Bleeding disorders or known clotting disorders (including heparin-induced thrombocytopenia),contraindications to antiplatelet therapy, or rejection of transfusions; 3. Sepsis or severe infection within 1 month prior to occlusion; 4. Patients with thrombosis at the occluder placement and venous thrombosis at the catheter insertion site; 5. Cardiac malformation dependent on ventricular septal defect (VSD); 6. Not suitable for treatment with this product.

Design outcomes

Primary

MeasureTime frameDescription
success rate of occlusion at 6 months after the surgery6 months after the surgerySuccessful occlusion is that when follow-up under echocardiography at 6 months after surgery, the occlusion site shows no residual shunt or only a small amount of residual shunt.

Secondary

MeasureTime frameDescription
Surgical technique success rateImmediately after surgeryAfter the occluder was implanted with surgical intervention transport device (test group) or occluder and intervention transport device (control group), the occluder was released safely.
technique success rateImmediately after surgeryAfter the occluder was implanted with occluder and surgical intervention transport device (test group) or occluder and intervention transport device (control group), the occluder was released safely and no occluder detachment occurred during the operation.

Countries

China

Contacts

Primary ContactPan Xiangbin, MD, Ph.D
Xiangbin428@hotmail.com010-88396666

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026