Optimised MultiSite Pacing Vector Study

Multimodality Assessment of Acute and Long Term Response to Optimised MultiSite Pacing Cardiac Resynchronisation (MSP CRT) Devices Compared to Biventricular (BiV) CRT, in Patients With Heart Failure

Status
Withdrawn
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03938090
Enrollment
0
Registered
2019-05-06
Start date
2019-12-01
Completion date
2023-11-01
Last updated
2025-05-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure, Left Bundle-Branch Block, Systolic Dysfunction

Keywords

Cardiac Resynchronization Therapy, MultiSite Pacing

Brief summary

The objective of this clinical investigation is to evaluate the clinical benefits of an MultiSite pacing (MSP) with patient specific left ventricular vector optimization in patients receiving cardiac resynchronization therapy (CRT) after 6 months of therapy. This clinical investigation is a single-center, prospective, two-arm, randomized 1:1, crossover study designed to evaluate the effectiveness of Optimized MSP CRT compared to conventional bi-ventricular pacing. Data will be collected at enrolment, CRT implant procedure, hospital pre-discharge, one, three and six months post implant. Enrolment data collection will include demographics, cardiovascular history, medication, echocardiography measurements, heart failure quality of life questionnaire and six minute walk test distance. CRT implant procedure data collection will include implanted system information, lead location and conduction times. The electrical conduction recording procedure will include surface ECG and device electrogram (EGM) recordings during various MSP vector pacing configurations at the time of CRT device implant. Patients will also undergo simultaneous invasive pressure measurements using a left ventricular pressure wire to allow haemodynamic measurements (dP/dtmax) during various MSP vector pacing configurations. Optimal MSP programming settings will be determined by the narrowest QRS duration recorded by 12 lead ECG and the greatest change in dP/dtmax by pressure wires study. In a subgroup of patients (approximately 25 patients), non-invasive electrical activation data will be collected with electrocardiographic imaging (ECGi) within 45 days of the implant procedure. Patients will then be randomized 1:1 to receive either standard biventricular pacing or Optimized MSP at their one-month follow-up (± 15 days) visit. At the 3 months (± 15 days) post randomization follow up visit, data collection will include surface ECG, EGMs, echocardiographic parameters and quality of life questionnaire. The patients will then undergo cross-over to the alternate randomization group with programming adjusted accordingly. At the final, 6 months (± 15 days) post randomization follow-up visit, data collection will include surface ECG, EGMs, echocardiographic parameters and quality of life questionnaire. This will mark the completion of the study for each patient. The expected duration of enrolment is 18 months. The total duration of the clinical investigation is expected to be 25 months.

Interventions

DEVICEOptimised MultiSite Pacing

The intervention includes using optimal programming settings with MultiSite pacing configurations via the patient's CRT device. The device in use is the same for each arm, the only changes are the programming settings.

Conventional programming settings using biventricular pacing will be used

Sponsors

Boston Scientific Corporation
CollaboratorINDUSTRY
Barts & The London NHS Trust
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Investigator)

Intervention model description

Single-center, prospective, two-arm, randomized 1:1, crossover study

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Symptomatic Heart Failure (NYHA class I-IV) with QRS duration of 150ms or more with left bundle branch block and LVEF of 35% or less despite optimal medical therapy. * Patients above 18 years of age * Able to provide informed consent and willing to comply with study requirements * Intrinsic QRS duration ≥ 150 ms * Sinus (or atrial paced) rhythm with intact AV conduction (PR interval ≤250 ms)

Exclusion criteria

* Resting heart rate \> 100 bpm * High degree AV Block (2nd or 3rd degree AV block) * Documented persistent atrial arrhythmia at the moment of enrolment or patients not likely to remain in sinus (or atrial paced) rhythm for the duration of the study * Patients scheduled for AV node ablation to treat atrial arrhythmias * Recent (\< 3 months) myocardial infarction, catheter ablation, electrolyte imbalance, or any condition within the last 90 days that would contraindicate CRT programming changes in the opinion of the investigator * Women who are pregnant or plan to become pregnant during the study course * Known left ventricular thrombus

Design outcomes

Primary

MeasureTime frameDescription
Echocardiographic clinical response3 and 6 months post randomizationResponse to optimised MSP CRT compared to BiV CRT defined by LV systolic volume reduction of greater than 15% (indicative of reverse remodelling) at completion of follow up.

Secondary

MeasureTime frameDescription
Acute changes in surface ECG QRS duration and morphologyAcute change in QRS duration with pacing compared to intrinsic QRS duration, measured during pacing programming protcol at device implantQRS duration changes with CRT programming optimisation
Acute change in LV dP/dtmaxAcute change in LV dP/dtmax with pacing compared to intrinsic rhythm, measured during pacing programming protcol at device implantChanges in LV contractility as assessed by pressure wire
Change in exercise capacity by 6MWT distancePre-implant, 3 and 6 months post randomization6 minute walk test distance
Change in NYHA functional classPre-implant, 3 and 6 months post randomizationNew York Heart Association Functional class

Other

MeasureTime frameDescription
Sub-group outcome: assessment of LV activation timings with ECGi1 month post implantElectrocardiographic imaging

Countries

United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026