ECG for Programming in CRT

Electrocardiogram for Programming in Cardiac Resynchronization Therapy

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03936608
Acronym
EPIC
Enrollment
4
Registered
2019-05-03
Start date
2019-04-22
Completion date
2019-11-21
Last updated
2020-12-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Resynchronization Therapy, Electrocardiography, Systolic Heart Failure

Keywords

CRT Programming

Brief summary

Patients with heart failure and left bundle branch block benefit from Cardiac Resynchronization Therapy (CRT) that delivers pacing from right ventricle (RV) and left ventricle (LV) synchronously, resulting in electrical ventricular resynchrony followed by revere structural cardiac remodeling and thereby reduced heart failure symptoms, hospitalizations and death. It is not known if programming an individually optimized RV-LV pacing offset to maximize electrical resynchrony can improve benefit from CRT. The proposed study is a randomized controlled trial in patients undergoing implant of a CRT pacemaker/defibrillator device for clinical indications to evaluate benefit of RV-LV offset programming using electrocardiogram (ECG) vs. standard nominal CRT programming without RV-LV offset. Patients receiving CRT devices will be randomized to either (A) active intervention of programming RV-LV pacing offset to optimize ECG or to (B) active control of nominally programming CRT device without RV- LV offset. The patients will be followed to evaluate change in echocardiogram, quality of life, functional evaluation and a blood marker for heart failure.

Detailed description

Once the eligibility for the study is determined and patient has consented for participation, all study participants will undergo a baseline evaluation (within 6 weeks prior to 2 weeks after CRT device implant/upgrade). Echocardiogram, quality-of-life questionnaire, 6-minute hall walk, blood test, vital signs, ECGs, device interrogation and baseline demographic and medical history including chart review will be obtained. After CRT device implant/upgrade, participants will undergo physiologic evaluations at various (up to 10 or more) RV-LV offset settings including ECGs and echocardiography. A randomized assignment using a random allocation table in REDCap will be used to program patients to (A) intervention or (B) control RV-LV offset setting. Patients will return for study follow-up between 3-12 months. Follow-up evaluations will include echocardiography, quality-of-life questionnaire, 6-minute hall walk test, blood test, vital signs, ECGs, device interrogation, and follow-up medical history including chart review. The patients will continue to be in extended follow-up through review of their medical charts till the end of the study (12 months from date of CRT implant/upgrade of the the last study participant). Treatment and control arms: All study patients will receive standard of care clinically indicated medical and device therapy per their treating physicians. After implant of a clinically indicated CRT device or upgrade of a preexisting pacemaker or defibrillator device to CRT system, participants will be randomized 1:1 to treatment arms (A) active intervention of programming individualized RV-LV pacing offset to optimize ECG or to (B) active control of nominally programming CRT device without RV-LV offset. Of note, both intervention and control treatment are active FDA-approved CRT therapies and no investigational device or programming will be used, and no clinically indicated treatment will be withheld from any patient. At any time, if in the judgment of the patient's treating physicians or the research team, any treatment including CRT programming different from the study protocol is necessitated for clinical reasons, the appropriate clinically indicated changes will be made. At the end of the study, if the participant is clinically doing well and the programmed CRT settings are deemed clinically appropriate they will be retained, else the CRT programming may be changed as per standard of care. Enrolled participants who have a failed or unsatisfactory LV lead implant will not be randomized.

Interventions

DEVICEProgramming individualized RV-LV pacing offset to optimize ECG

After CRT device implant, participants will undergo physiologic evaluations at various (up to 10 or more) RV-LV offset settings including ECGs. The RV-LV offset that optimizes the paced QRS morphology on ECG will be programmed.

DEVICENominally programming CRT device without RV-LV offset

After CRT device implant, participants will undergo physiologic evaluations at various (up to 10 or more) RV-LV offset settings including ECGs. Nominal standard-of-care CRT programming with no RV-LV offset will be programmed.

Sponsors

Washington University School of Medicine
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

* Patients ≥18 years of age who are able to give consent. * Diagnosis of systolic heart failure. * Planned to undergo new CRT device implant (or upgrade of preexisting pacemaker or defibrillator device to CRT system) for standard clinical indications. * Expected to have over 95% heart beats resynchronized with CRT (absence of competing arrhythmias or plans to not immediately activate CRT therapy).

Exclusion criteria

* Unable to comply with the study follow-up. * Life expectancy ≤1 year.

Design outcomes

Primary

MeasureTime frameDescription
The Primary Outcome is Echocardiographic LV End-systolic Volume.3-12 monthsLV end-systolic volume is a reliable surrogate for clinical outcomes in clinical heart failure trials.

Countries

United States

Participant flow

Participants by arm

ArmCount
Individualized RV-LV Pacing Offset
Programming individualized RV-LV pacing offset to optimize ECG: After CRT device implant, participants will undergo physiologic evaluations at various (up to 10 or more) RV-LV offset settings including ECGs. The RV-LV offset that optimizes the paced QRS morphology on ECG will be programmed.
2
No RV-LV Pacing Offset
Nominally programming CRT device without RV-LV offset: After CRT device implant, participants will undergo physiologic evaluations at various (up to 10 or more) RV-LV offset settings including ECGs. Nominal standard-of-care CRT programming with no RV-LV offset will be programmed.
2
Total4

Baseline characteristics

CharacteristicIndividualized RV-LV Pacing OffsetNo RV-LV Pacing OffsetTotal
Age, Continuous66 years43 years54.5 years
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Black or African American
0 Participants0 Participants0 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Race (NIH/OMB)
White
2 Participants2 Participants4 Participants
Randomization Groups2 Participants2 Participants4 Participants
Sex: Female, Male
Female
2 Participants1 Participants3 Participants
Sex: Female, Male
Male
0 Participants1 Participants1 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 20 / 2
other
Total, other adverse events
0 / 20 / 2
serious
Total, serious adverse events
0 / 20 / 2

Outcome results

Primary

The Primary Outcome is Echocardiographic LV End-systolic Volume.

LV end-systolic volume is a reliable surrogate for clinical outcomes in clinical heart failure trials.

Time frame: 3-12 months

Population: Study prematurely terminated, no data analysis was performed