Caretaker vs. Blood Pressure Monitoring With Invasive Arterial Pressure Monitoring in Patients With Septic Shock

Comparison of Noninvasive Blood Pressure Monitoring With Invasive Arterial Pressure Monitoring in Patients With Septic Shock

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03933722
Enrollment
40
Registered
2019-05-01
Start date
2019-02-04
Completion date
2024-02-05
Last updated
2024-02-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Blood Pressure

Brief summary

Caretaker vs. Blood Pressure Monitoring With Invasive Arterial Pressure Monitoring in Patients With Septic Shock

Detailed description

The aim of this study is to compare blood pressure obtained using routine blood pressure sphygmomanometer, in patients with invasive arterial pressure monitoring that have septic shock, to a non-invasive device that continuously monitors central blood pressure (CareTaker).

Interventions

DEVICECaretaker

Application of Caretaker device to subjects that have septic shock and that have an invasive arterial pressure monitor placed.

Sponsors

The Cooper Health System
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Admitted with septic shock, with or without vasopressor support needed. * Greater than or equal to 18 years of age. * Have an arterial catheter already in place.

Exclusion criteria

* No arterial catheter in place. * Contraindication to the application of the Caretaker device due to pre-existing finger injury. * Patients in whom use of a BP cuff is contraindicated.

Design outcomes

Primary

MeasureTime frameDescription
Comparing blood pressure measurements by the Caretaker device to blood pressure measurements made with an intra-arterial pressure catheter.20 minutesThe primary outcome measure will be the average difference in systolic and diastolic blood pressure measurements between the investigational device (Caretaker) and the reference (intra-arterial catheter pressure) in subjects that have septic shock. In line with blood pressure validation guidelines, we will obtain multiple investigational-reference measurement pairs in each subject (20 minutes total) and will average the difference over all pairs from all subjects.

Secondary

MeasureTime frameDescription
Comparing blood pressure measurements by the Caretaker device to blood pressure measurements made with an upper arm cuff.20 minutesSecondary outcome measure will be the average difference in systolic and diastolic blood pressure measurements between the investigational device (Caretaker) and a brachial cuff in subjects that have septic shock. In line with blood pressure validation guidelines, we will obtain multiple investigational-reference measurement pairs in each subject (4 pairs over 20 minutes) and will average the difference over all pairs from all subjects.