Measuring Soft Tissue Thickness by CBCT

Accuracy of Cone Beam Computed Tomography in Measuring of Mandibular Pig Soft Tissue Thickness Using a Radiopaque Material in Comparesion With Real Measurement.Diagnostic Study

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03932357
Enrollment
15
Registered
2019-04-30
Start date
2019-04-20
Completion date
2021-12-09
Last updated
2021-08-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cone Beam Computed Tomography

Brief summary

accuracy of CBCT in measuring soft tissue thickness by using a radiopaque material as the real finding and measurements on pig jaws

Detailed description

* Pig jaws will be included in this study. * Soft tissue surfaces were lightly covered with barium sulfate powder using a powder spray. CBCT was taken. * A periodontal probe and a rubber stop were used for the measurement of trans-gingival probing thickness (TPT). * After that, flap were elevated, and actual thickness of soft-tissue (actual thickness, AT) was measured. The Analytical phase: * In order to assess soft tissue thickness and bone levels an electronic digital caliper (Shenhan Measuring Tools Co., LTD, Shanghai) will used for measuring the transgingival probing thickness on the pig jaws. * A graduated Naber's probe will be used for measuring the transgingival probing thickness. Soft tissue thickness measurements: * Intra-observer variability was tested under the supervision of the director. * For the measurement of radiographic thickness (RT), wet soft tissue surfaces were covered with barium sulfate powder (SoloTop; Taejoon, Seoul, Korea), a radiopaque material used as a contrast medium. * A probes and rubber stop were used for the measurement of transgingival probing thickness (TPT). * A rubber stop was placed in contact with the surface to facilitate the measurement of tissue thickness, and then TPT was measured with digital calipers. All measurements were rounded to the nearest 0.01 mm. * For the measurement of actual thickness (AT), an incision was made onto each marked area. After flap elevation, actual soft tissue thickness was measured using the same method that was used for TPT. Radiographic examination * The pig jaws will then be imaged with CBCT. * CBCT scanning will be performed using a PROMAX R 3DMid CBCT device (Planmeca Oy, Helsinki, Finland) with scanning protocol 90 kVp, 8 mA and 13.58 seconds exposure time with a single 360 degree rotation ROMEXIS software. The jawes will be placed on the horizontal plate of the device. The midline and mandibular position will be adjusted using the laser guide

Interventions

RADIATIONCBCT

measuring soft tissue thickness using a CBCT

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* The study samples will not identified by age or gender group. * The selected pig jaw should be intact with no mechanical damage. * jaw with attached natural teeth

Exclusion criteria

* Teeth with anomalies and fractures. * Periodontally affected teeth

Design outcomes

Primary

MeasureTime frameDescription
cbct6 monthsmeasuring soft tissue thickness using cbct in pig jaw

Secondary

MeasureTime frameDescription
Acutal thickness measurement6 monthsperiodontal probe was inserted vertically into the soft tissue surface until resistance of the bone was felt . A rubber stop was placed in contact with the surface to facilitate the measurement of tissue thickness.actual thickness was measured with digital calipers