Skip to content

The Homburg Keratoconus Center (HKC)

The Homburg Keratoconus Center (HKC) - a Keratoconus Observation Study

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03923101
Enrollment
5000
Registered
2019-04-22
Start date
2011-01-01
Completion date
2036-01-01
Last updated
2026-04-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Keratoconus

Keywords

Keratoconus, Crosslinking, Intracorneal ring segments, Gas-permeable rigid contact-lenses, Penetrating Keratoplasty, Deep anterior lamellar Keratoplasty, ABCD Grading System

Brief summary

Aim of this study is to conduct longitudinal and cross-sectional analyses about the corneal ectatic disease Keratoconus based on data obtained from Keratoconus patients in the Homburg Keratoconus Center (HKC). The Homburg Keratoconus Center (HKC) was founded in 2010 and, up to now, comprises more than 3,000 Keratoconus patients. Topographic, tomographic and biomechanic characteristics of the disease are being analyzed with the intention to elucidate how the disease begins and develops during lifetime.

Interventions

DIAGNOSTIC_TESTTopographic, tomographic and biomechanical analysis.

The study is based upon data obtained during routine medical follow-ups using 1. the Pentacam high resolution (Oculus, Wetzlar, Germany) 2. the Corvis ST (Oculus, Wetzlar, Germany) 3. the Anterior-Segment Optical Coherence Tomograph (AS-OCT) Casia 2 (Tomey, Nagoya, Japan) 4. the Ocular Response Analyzer (Reichert Technologies, New York, USA).

Sponsors

Universität des Saarlandes
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
OTHER

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* All Keratoconus patients presenting in the department of ophthalmology, Saarland University Medical Center, Homburg, Saarland, Germany.

Exclusion criteria

* Patients without Keratoconus.

Design outcomes

Primary

MeasureTime frameDescription
An overview about development of anterior corneal curvature in Keratoconus disease during lifetime.01/01/2011-01/01/2019The anterior radius of curvature (ARC, 3mm zone) of Keratoconus patients as measured by the Pentacam high resolution (Oculus, Wetzlar, Germany) at different ages (according to: Belin MW and Duncan JK. Keratoconus: The ABCD grading system. Klin Monbl Augenheilkd. 2016; 233(6): 701-707) is put into relation to the age of the Keratoconus patients.
An overview about development of posterior corneal curvature in Keratoconus disease during lifetime.01/01/2011-01/01/2019The posterior radius of curvature (PRC, 3mm zone) of Keratoconus patients as measured by the Pentacam high resolution (Oculus, Wetzlar, Germany) at different ages (according to: Belin MW and Duncan JK. Keratoconus: The ABCD grading system. Klin Monbl Augenheilkd. 2016; 233(6): 701-707) is put into relation to the age of the Keratoconus patients.
An overview about development of the thinnest corneal pachymetry in Keratoconus disease during lifetime.01/01/2011-01/01/2019The thinnest corneal pachymetry of Keratoconus patients as measured by the Pentacam high resolution (Oculus, Wetzlar, Germany) at different ages (according to: Belin MW and Duncan JK. Keratoconus: The ABCD grading system. Klin Monbl Augenheilkd. 2016; 233(6): 701-707) is put into relation to the age of the Keratoconus patients.
An overview about development of the best corrected distance visual acuity in Keratoconus disease during lifetime.01/01/2011-01/01/2019The best corrected distance visual acuity of Keratoconus patients as raised as part of the clinical examination at different ages (according to: Belin MW and Duncan JK. Keratoconus: The ABCD grading system. Klin Monbl Augenheilkd. 2016; 233(6): 701-707) is put into relation to the age of the Keratoconus patients.
Reproducibility study: Kmax.01/01/2011-01/01/2019Measurements of Kmax measured by different devices (Pentacam high resolution, Oculus, Wetzlar, Germany; Anterior-Segment Optical Coherence Tomograph (AS-OCT) Casia 2, Tomey, Nagoya, Japan) are being compared and set into relation at different Keratoconus stages with the intention to investigate, whether measurement inaccuracies occur at later Keratoconus stages using different devices.
Reproducibility study: Thinnest corneal pachymetry.01/01/2011-01/01/2019Measurements of the thinnest corneal pachymetry as measured by different devices (Pentacam high resolution, Oculus, Wetzlar, Germany; Anterior-Segment Optical Coherence Tomograph (AS-OCT) Casia 2, Tomey, Nagoya, Japan) are being compared and set into relation at different Keratoconus stages with the intention to investigate, whether measurement inaccuracies occur at later Keratoconus stages using different devices.
Reproducibility study: Thinnest corneal pachymetry at the apex position.01/01/2011-01/01/2019Measurements of the thinnest corneal pachymetry at the apex position as measured by different devices (Pentacam high resolution, Oculus, Wetzlar, Germany; Anterior-Segment Optical Coherence Tomograph (AS-OCT) Casia 2, Tomey, Nagoya, Japan) are being compared and set into relation at different Keratoconus stages with the intention to investigate, whether measurement inaccuracies occur at later Keratoconus stages using different devices.

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 28, 2026