Pleth Variability Index for Directed Fluid Optimization in Donors in Living Donor Liver Transplantation

The Accuracy of Pleth Variability Index for Directed Fluid Optimization in Donors in Living Donor Liver Transplantation

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03921125
Enrollment
40
Registered
2019-04-19
Start date
2018-10-09
Completion date
2019-10-20
Last updated
2019-06-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fluid Response

Keywords

Living donors, PVI, PPV, Fluids, Response

Brief summary

In this Study we are trying to validate the accuracy of Plethogram variability index in predicting fluid responsiveness compared to pulse pressure variation in donors of liver transplantation

Detailed description

The liver transplantation program at Ain Shams University Hospitals relies on related living donors. Extra care during anesthetic management of the donor is warranted because of clear ethical considerations. This prospective observational study was performed after obtaining approval from the ethical committee of the Ain Shams University FWA R 53/2018. Sample of 40 healthy ASA I or II donors' candidate for right lobe hepatectomy for living donor liver transplantation (LDLT) were included and consent was taken. Conventional form of anesthesia was induced with left radial arterial line inserted for invasive blood pressure monitoring, frequent blood gases and lactate sampling, and measuring the PPV, Right insertion of internal jugular vein line for CVP measurement. Fluid management in the form of ringer acetate 3-5 ml/kg/hr recruitment of the patients (Hypovolemic donors) depends on the presenting signs that led the anesthesiologist to decide if the patient's volume status was hypovolemic and in need for fluid replacement without presence of surgical mechanical compression on the IVC or Liver during dissection phase. These diagnostic criteria for volume assessment were heart rate (HR) more than 100 beats/min, systolic arterial blood pressure (SAP) less than 90 mmHg. Assessment of Hemodynamics during periods of Hypovolemia After exclusion of any surgical mechanical compression, all enrolled hypovolemic patients had left radial arterial line measuring PPV using Drager Monitor and a pulse oximeter measuring PVI using Device Masimo. This device measures the perfusion index which is the indicator of the amplitude of the signal of PVI, confirmation of the wave signal should be obtained from any finger, fingers should be kept warm before test is done. Hypovolemic patients were given a fluid bolus in the form of ringer acetate 5 ml / Kg over 10 minutes. At the end of volume expansion another recorded PPV and PVI are done. Primary outcome was the correlation between PPV and PVI before and after fluid resuscitation

Interventions

DEVICEMassimo for Pleth variability index

To assess fluid response

Sponsors

Ain Shams University
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
20 Years to 40 Years
Healthy volunteers
No

Inclusion criteria

* Sample of 40 healthy ASA I or II donors' candidate for right lobe hepatectomy for living donor liver transplantation

Exclusion criteria

* Lack of consent

Design outcomes

Primary

MeasureTime frameDescription
Correlation between PPV and PVI before and after fluid resuscitation.6 hoursAssess accuracy of device in fluid response

Countries

Egypt