Circulatory Failure, Fluid Volume Disorder, Critical Illness
Conditions
Brief summary
Patients in ICU who suffer from circulatory insufficiency, regardless the cause that require invasive hemodynamic monitoring. The aim of the study is to correlate stroke volume variation which predicts fluid responsiveness with change of the blood pressure after intravenous admission of propofol. This test could become a surrogate of stroke volume variation in patients with contraindications to minimally invasive hemodynamic monitoring.
Detailed description
This prospective, observational study was conducted after approval of the Independent Bioethics Commitee at Medical University of Gdańsk (numer zgody) and registered in ClinicalTrials.gov. Mechanically ventilated patients of intensive care unit who routinely recieved haemodynamic monitoring with PiCCO™ (Getinge AB, Sweden) technology using Philips IntelliVue PiCCO-Module (Philips Healthcare, Amsterdam, Netherlands), were enrolled. Patients were sedated with midazolam infusion at 0,15 to 0,6 mg kg-1 h-1 . Before the trial in each patient, heart rate (HR) invasive (IBP) and non - invasive blood pressure, (NIBP) infusion rate of catecholamines and non adrenergic vasopressors was recorded and PiCCO device was callibrated by transpulmonary thermodilution with 20 ml of cold saline. Global end diastolic volume (GEDV), intrathoracic blood volume (ITBV) and stroke volume variation (SVV) were calculated and recorded. For effective ventilation with increased tidal volume of 8 ml kg-1 of Predicted Body Weight, each patient recieved propofol bolus of 0,25 mg kg-1, 0,5 mg kg-1 and 1,0 mg kg-1 consecutively. Higher doses were used at good tolerance of the lower ones. After each bolus systolic and diastolic invasive blood pressure, heart rate (HR), continuous cardiac output (CCO), continuous cardiac index (CCI), stroke volume index (SI), stroke volume variantion (SVV), and left ventricular contractility index (dPmax) were recorded every fifteen seconds for ten minutes. The absolute and realtive change in blood pressure, compared to the values of blood pressure before the drug administration, were correlated with SVV. Time interval between each examination ranged from 4 to 48 hours.
Interventions
Each patient gets propofol bolus in three doses. 0.25 mg/kg, 0.5 mg/kg and 1 mg/kg. After each dose patient's blood pressure, heart rate and haemodynamic values calibrated with PICCO device (cardiac output, cardiac index, stroke index, stroke volume, stroke volume variation, dPmax) are recorded in 15 seconds intervals for 10 minutes.
Sponsors
Study design
Eligibility
Inclusion criteria
ICU patient Haemodynamically instable Mechanically ventilated
Exclusion criteria
Simultaneous propofol infusion Contraindications for propofol Atrial fibrillation Valvular malfunction Aortic stenosis Aortic aneurysm
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Blood pressure | 10 minutes | Change in blood pressure values after propofol bolus. |
| Heart rate | 10 minutes | Change in heart rate values after propofol bolus. |
| Cardiac output | 10 minutes | Change in cardiac output values after propofol bolus. |
| Cardiac index | 10 minutes | Change in cardiac index values after propofol bolus. |
| Stroke volume | 10 minutes | Change in stroke volume values after propofol bolus. |
| Stroke index | 10 minutes | Change in stroke index values after propofol bolus. |
| Stroke volume variation | 10 minutes | Change in stroke volume variation values after propofol bolus. |
| Maximum left ventricular contractility (dPmax) | 10 minutes | Change in dPmax values after propofol bolus. |
Countries
Poland