Evaluation of STARgraft AV for Hemodialysis Access

First in Human Evaluation of STARgraft AV for Hemodialysis Access in Comparison to ePTFE Vascular Grafts

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03916731
Enrollment
55
Registered
2019-04-16
Start date
2019-04-02
Completion date
2021-05-11
Last updated
2024-10-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

End Stage Renal Disease

Keywords

Hemodialysis, Vascular Access, Arterio-Venous Grafts (AVG)

Brief summary

This study is a First-in-Human, single site, prospective, randomized, controlled evaluation of the safety and effectiveness of the Healionics STARgraft AV hemodialysis access graft. The STARgraft has been demonstrated in preclinical studies to have improved resistance to the common failure mode of venous anastomosis stenosis. Performance of the STARgraft AV will be compared against control implants of commercially available standard ePTFE grafts approved for the same use. The study is enrolling patients with End Stage Renal Disease (ESRD) requiring hemodialysis via a prosthetic vascular graft. The study proposes to: 1. Demonstrate improved primary patency of the investigational STARgraft AV compared to the ePTFE controls over a period of 6 months, with extended results to 1 year. 2. Verify safety of the STARgraft AV multilayer construction in extended vascular access use. It is intended to enroll 25 subjects each for the investigational devices and the controls respectively (50 total) with randomized device allocation at subject presentation for implant surgery.

Interventions

DEVICESTARgraft AV

Implant of STARgraft AV shunt in the upper arm and subsequent use for hemodialysis access. After healing from the surgical procedure the graft will be routinely cannulated for hemodialysis sessions. Periodic evaluations of blood flow by ultrasound imaging will be made over the study period. Established standards of care will be followed as needed to maintain dialysis function.

DEVICEePTFE AV graft (control)

Implant of standard ePTFE AV shunt as a control in the upper arm and subsequent use for hemodialysis access. After healing from the surgical procedure the graft will be routinely cannulated for hemodialysis sessions. Periodic evaluations of blood flow by ultrasound imaging will be made over the study period. Established standards of care will be followed as needed to maintain dialysis function.

Sponsors

Healionics Corporation
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Caregiver)

Masking description

Randomized Assignment of Investigational and Control devices by Sponsor. Participants and Dialysis Clinics providing routine maintenance hemodialysis care are masked.

Intervention model description

Equal numbers of Participants are randomly assigned investigational or control grafts for implant. Study follow up examinations and routine dialysis procedures over the study period are identical for both groups.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Male or female, \> 18 years or age. 2. Patient has given informed consent to participate in the trial. 3. Stated willingness to comply with all study procedures and availability for the duration of the study. 4. Able to effectively communicate with study personnel. 5. Candidate for a new arterio-venous graft placed in the upper arm. 6. Life expectancy judged to be at least 2 years. 7. Axillary vein of greater than or equal to 7 mm in diameter. 8. Brachial artery of greater than or equal to 4 mm in diameter. 9. Systolic blood pressure equal to or greater than 120 mmHg. 10. Absence of central venous stenosis downstream from implant site confirmed with ultrasound and/or angiogram.

Exclusion criteria

1. Unable or unlikely to comply with trial protocol and/or follow-up. 2. Pregnancy. 3. Clinical morbid obesity. 4. Anatomical limitations. 5. Immunodeficiency syndrome. 6. History of bacterial infection within 8 weeks prior to graft implantation. 7. History of hypercoagulation or bleeding disorders. 8. Elevated platelet count \> 1 million per microliter of blood. 9. History of heparin-induced thrombocytopenia syndrome (HIT). 10. Medically confirmed stenosis of the veins downstream of the implant site. 11. Inadequate arterial flow or pressure proximal to the implant site. 12. Currently participating in another investigation drug or device study which may clinically interfere with any endpoints of this trial. 13. Fever greater than 38° C. 14. Prior allergic reaction to silicone.

Design outcomes

Primary

MeasureTime frameDescription
Primary Unassisted Patency12 months post implantation.Percentage of subjects without an occurrence of either an access thrombosis or an access procedure performed to maintain patency.

Secondary

MeasureTime frameDescription
Primary Unassisted Patency1, 2, 4, 9 and 12 months post implantationPercentage of subjects without an occurrence of either an access thrombosis or an access procedure performed to maintain patency.
Assisted Primary Patency1, 2, 4, 6, 9 and 12 months post implantationPercentage of subjects retaining patency after one or more interventions so long as patency was not lost at any point.
Secondary Patency (Cumulative Patency)1, 2, 4, 6, 9 and 12 months post implantationPercentage of subjects without loss of access at the original implant site.
Graft Related Infections1, 2, 4, 6, 9 and 12 months post implantationFrequency of infections related to graft placement and use for dialysis access.
Safety Outcomes1, 2, 4, 6, 9 and 12 months post implantationFrequency and Severity of Adverse Events resulting from graft implantation and use for hemodialysis access.

Other

MeasureTime frameDescription
Blood flow rates in grafts.2 weeks and 1, 2, 4, 6, 9, 12 months post implantation.Ultrasound measurements of flow rates (ml/minute) to detect patency trends with time after implantation
Peak Systolic Velocity (PSV) Ratio2 weeks and 1, 2, 4, 6, 9, 12 months post implantationUltrasound measurement of PSV (The ratio of flow velocity at the venous anastomosis to that at a point 2cm upstream in the graft)

Countries

Paraguay

Outcome results

None listed