Skip to content

TReAtmeNt of Small Coronary Vessels: MagicTouch Sirolimus Coated Balloon

Magic Touch Sirolimus Coated Balloon (Concept Medical) Versus SeQuent Pease Neo Paclitaxel Coated Balloon (Bbraun) for the Treatment of de Novo Coronary Artery Lesions in Small Vessels

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03913832
Acronym
TRANSFORM I
Enrollment
121
Registered
2019-04-12
Start date
2020-08-28
Completion date
2023-09-10
Last updated
2022-10-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease, DCB

Keywords

small vessel, sirolimus, drug coating balloon

Brief summary

The study is a prospective, multinational (Italy, Ireland and UK), multicenter, randomised Clinical Trial that compares the efficacy and performance of two drug coated balloon (DCB), the MAGIC TOUCH sirolimus coated balloon (Concept Medical) and SeQuent Please paclitaxel coated balloon (B Braun). The objective of the study is to compare angiographic outcomes of Magic TouchTM sirolimus coated balloon (Concept Medical) versus SeQuentTM paclitaxel coated balloon (Bbraun) for the treatment of de novo coronary artery lesions in small vessels (≤2.75 mm) with respect to Net Gain (mm) at 6 months follow-up

Detailed description

A prospective, randomized, multi-centre study in subjects with small vessels, i.e. at least one de-novo lesion in a small vessel (≤2.75mm). Vessel size will be determined first by QCA on-line (screening, pre-procedure). If, based on QCA on-line the vessel size pre-procedure is ≤2.75mm and following a successful pre-dilatation (i.e. no angiographic dissections type CDEF and TIMI\>2), the subject will be randomized in a 1:1 fashion to Magic Touch or SeQuent Please Neo. OCT will be performed post pre-dilatation (guidance) prior to drug coated balloon (DCB) treatment. The DCB balloon size will be selected based on OCT measurements.

Interventions

DEVICEsirolimus drug coated balloon (SCB)

Magic TouchTM (Concept Medical) is a sirolimus drug coated balloon (SCB) for PCI, based on a polymer-free and Nano based drug delivery technology. Magic Touch SCB is a product of CMI proprietary drug delivery technology Nanolute. It is indicated (CE approved) for ISR, small vessels, bifurcation lesions & de novo lesions.

DEVICEpaclitaxel releasing coronary balloon catheter

SeQuent PleaseTM (B. Braun Melsungen AG, Vascular Systems,Berlin, Germany) is a paclitaxel releasing coronary balloon catheter.

Sponsors

Concept Medicals BV
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Male or female patients ≥18 years 2. Patient with chronic stable angina or stabilized acute coronary syndromes with normal cardiac biomarker values Note: For patients showing elevated Troponin (e.g. non-STEMI patients) at baseline (within 72h pre-PCI) an additional blood sample must be collected prior to randomization to confirm that: * hs-cTn or Troponin I or T levels are stable, i.e. the value should be within 20% range of the value found in the first sample at baseline, or have dropped * CK-MB and CK levels are within normal range If hs-cTn or Troponin I or T levels are stable or have dropped, the CK-MB and CK levels are within normal ranges, and the ECG is normal, the patient may be included in the study. 3. The patient has a planned intervention in one or two separate major epicardial territories (LAD, LCX or RCA) and has at least one de-novo lesion in a small vessel (≤2.75mm by QCA prior to pre-dilatation) 4. Target lesion length ≤30 mm 5. Able to understand and provide informed consent and comply with all study procedures including 6 months angiographic follow-up 6. Patient must have completed the follow-up phase of any previous study

Exclusion criteria

1. Patient is a woman who is pregnant or nursing (a pregnancy test must be performed within 7 days prior to the index procedure in women of child-bearing potential) 2. Evidence of ongoing acute myocardial infarction (AMI) in ECG and/or elevated cardiac biomarkers (according to local standard hospital practice) have not returned within normal limits at the time of procedure 3. Known contraindication or hypersensitivity to sirolimus, paclitaxel, or to medications such as aspirin, heparin, and all of the following four medications: clopidogrel bisulfate, ticlopidine, prasugrel, ticagrelor 4. Patient suffered from stroke/TIA during the last 6 months 5. LVEF \<30% 6. Platelet count \<100,000 cells/mm3 or \>400,000 cells/mm3, a WBC of \<3,000 cells/mm3, or documented or suspected liver disease (including laboratory evidence of hepatitis) 7. Known renal insufficiency (e.g. serum creatinine \>2.5mg/dL, or creatinine clearance ≤30 mL/min), or subject on dialysis, or acute kidney failure (as per physician judgment) 8. Patient undergoing planned surgery within 6 months with the necessity to stop DAPT 9. History of bleeding diathesis or coagulopathy 10. The patient is a recipient of a heart transplant 11. Concurrent medical condition with a life expectancy of less than 12 months 12. The patient is unwilling/not able to return for angiographic recatherisation at 6 month follow-up 13. Currently participating in another trial and not yet at its primary endpoint. Angiographic

Design outcomes

Primary

MeasureTime frameDescription
Net Gain (mm) In-segment6 MonthsThe primary endpoint is in-segment (balloon treated area) Net Gain (mm) at 6 months post-procedure.

Secondary

MeasureTime frameDescription
Procedure SuccessPost procedure (Right after the treatment with drug coated balloon)Successful delivery and inflation within 45 seconds of the allocated DCB device at all intended target lesion(s) during an attempt with a DCB not previously used (first use) and successful withdrawal of the device system with attainment of final in-lesion residual stenosis of \<30% (by QCA) without the occurrence of TLF during the index procedure hospital stay).
Acute/subacute/early/late vessel closure/thrombosis1, 6 months and 12 MonthsClosure by restenosis or thrombosis (diameter stenosis of 100% and/or TIMI grade 0).
Angiographic outcomes: late lumen loss6 monthsThe difference between the minimum lumen diameter (MLD) immediately after index procedure and the MLD at follow-up as measured in (preferable) identical orthogonal views (MLDpost - MLDfup).
Angiographic outcomes:Minimal lumen diameter6 monthsThe smallest lumen diameter in the segment of interest
Device successPost procedure (Right after the treatment with drug coated balloon)Successful delivery and inflation within 45 seconds of the allocated DCB device at the intended target lesion during an attempt with a DCB not previously used (first use) and successful withdrawal of the device system with attainment of final in-lesion residual stenosis of \<30% (by Quantitative Coronary angiography).
Angiographic outcomes: Restenosis rate6 monthsRestenosis is defined as ≥50% diameter stenosis at follow-up.
Device oriented Composite Endpoint (DoCE / TLF): Cardiac death1, 6 months and 12 MonthsAny death due to proximate cardiac cause (e.g. MI, low-output failure, fatal arrhythmia), unwitnessed death and death of unknown cause, all study procedure related deaths including those related to concomitant treatment.
Device oriented Composite Endpoint (DoCE / TLF): Target vessel: myocardial infarction (TV-MI)1, 6 months and 12 MonthsThe term myocardial injury should be used when there is evidence of elevated cardiac troponin values (cTn) with at least one value above the 99th percentile upper reference limit (URL) TV-MI: Myocardial Infarction not clearly attributable to a non-target vessel.
Device oriented Composite Endpoint (DoCE / TLF): clinically indicated target lesion revascularization(TLR)1, 6 months and 12 MonthsTLR is defined as any repeat percutaneous intervention of the target lesion or bypass surgery of the target vessel performed for restenosis or other complication of the target lesion.
Angiographic outcomes: Percent diameter stenosis6 monthsThe percentage of luminal narrowing of vessel segment of interest

Countries

Ireland, Italy, United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 25, 2026