Assessment of Performance and Safety of an Asymmetric Balloon in the Treatment of Intranasal Bleeding Managed in an Emergency Setting

Assessment of Performance and Safety of an Asymmetric Balloon in the Treatment of Intranasal Bleeding Managed in an Emergency Setting

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03912051
Acronym
BATSI
Enrollment
10
Registered
2019-04-11
Start date
2019-03-27
Completion date
2019-07-18
Last updated
2019-09-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Epistaxis

Brief summary

Between 10 and 12% of the general population suffers from epistaxis, out of which 10% would need to be medically managed. Most of patients treated for epistaxis are managed through emergency departments. The involvement of the ENT (ear, nose and throat) surgeon might be required in more complex situations in order to control bleeding. Usually, nasal packing packing is used as a first line option after failure of digital compression. Epistaxis balloons are often used after failure of nasal packing Balloons are effective in approximately 60% of the patients with a rapid control of bleeding by compression followed by an absence of rebreeding after balloon removal. The main challenges for patients treated with this device are i) pain upon balloon introduction and inflation ii) discomfort upon introduction in the nasal cavity as well as during balloon maintenance during 24 to 72 hours of tamponade iii) blood retention between distal and proximal balloons that favors infection iv) limited breathing capabilities through the nostrils which increases general discomfort v) negative aesthetic impact for the patient vi) septal and alar necrosis risk in case of prolonged compression. Moreover, epistaxis leading to an hospitalization between 24 to 48h are not rare (\>11 000 in France in 2017 according to ATIH). Those hospitalizations are often decided in order to ensure an optimal patient monitoring following packing or epistaxis balloon placement. In order to address those adverse events while keeping the same efficacy and avoiding hospitalizations or reducing their duration, the use of an asymmetric, more physiological, easy to use and mainly intranasal (discreet proximal extremity) is studied.

Interventions

DEVICEasymmetric balloon

Asymmetric balloon for treatment of intranasal bleeding

Sponsors

Dianosic
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age \> or = 18 years * Male and female * bleeding uncontrolled with digital compression * Patient registered at social security * Patient who gave informed consent

Exclusion criteria

* Allergy to xylocaine * Impossibility to give patient information (severe massive epistaxis, difficulty to understand, non awaken patient…) * Patient in custody of court * Patient under guardianship or curator

Design outcomes

Primary

MeasureTime frameDescription
Device performance12 daysAbsence of bleeding following balloon inflation during first 48 hours and absence of rebreeding following removal at 48 hours and 9 days following removal
Device safety12 daysPain score on a VAS (Visual Analogic Scale)

Secondary

MeasureTime frameDescription
QoL12 daysRhinoQoL (Rhino Quality of Life) score

Countries

France

Outcome results

None listed