Skip to content

Dual Energy CT as a Noninvasive Method to Screen for Gastroesophageal Varices

Dual Energy CT as a Noninvasive Method to Screen for Gastroesophageal Varices

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03910413
Enrollment
11
Registered
2019-04-10
Start date
2019-06-05
Completion date
2023-07-06
Last updated
2023-08-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Gastroesophageal Varices

Brief summary

Cirrhosis leads to portal hypertension and development of gastroesophageal varices, which are the most common cause for bleeding in cirrhosis and a major cause of death. The American Association for the Study of Liver Disease (AASLD) recommends screening endoscopy every 2 years to evaluate for gastroesophageal varices, and annual surveillance for those with small varices on endoscopy. Unfortunately, endoscopy is costly, requires sedation, is poorly tolerated, is subject to high inter-observer variability, and is associated with risks that include bleeding, esophageal injury and aspiration. Noninvasive methods for evaluation of gastroesophageal varices are needed. CT is noninvasive, rapid, less expensive than endoscopy, requires no sedation, provides a quantitative measure of the size of the varices, and allows for assessment of para-esophageal varices, varices in other body locations, ascites, other signs of portal hypertension, patency of liver vasculature, and detection, diagnosis and staging of hepatocellular carcinoma. Single-Energy CT (SECT) has relatively high accuracy in prospective studies for detection of any and large varices but is associated with suboptimal contrast opacification of gastroesophageal varices. Dual-Energy CT with the GE scanners with GSI Xtream (DECT) improves the contrast-to-noise ratio by 60% compared to SECT and is currently standard of care at UAB for evaluation of cirrhosis. The primary objective of this study is to determine the accuracy of DECT for detecting any varices and high-risk varices. The study hypothesis is that the accuracy (AUROC) of DECT will be \>0.90 and \>0.95 for detecting any and high-risk varices in a prospective pilot study (N=50) that uses endoscopy as the reference standard. This will be a single-center pilot observational prospective IRB-approved study. A total of 50 adult patients presenting to UAB Endoscopy for surveillance endoscopy to detect and grade gastroesophageal varices will be enrolled.

Detailed description

Cirrhosis leads to portal hypertension and development of gastroesophageal varices, which are the most common cause for bleeding in cirrhosis and a major cause of death. Bleeding varices have a 6-week mortality of 15%-25%. About 50% of patients with cirrhosis have varices, and 30% have large varices (\>5 mm) that are high risk for bleeding. The American Association for the Study of Liver Disease (AASLD) recommends screening endoscopy every 2 years to evaluate for varices, and annual surveillance for those with small varices on endoscopy. Patients at a high risk of bleeding with large varices, small varices and red wale signs (an endoscopic finding), or small varices and decompensated cirrhosis proceed to treatment such as prophylactic band ligation and beta blockers. Conversely, patients with no varices or small varices (≤5 mm) continue surveillance efforts by endoscopy to monitor for development of large varices. Unfortunately, endoscopy is costly, requires sedation, is poorly tolerated, is subject to high inter-observer variability, cannot detect other signs or portal hypertension or para-esophageal varices that are at risk for future bleeding events, and is associated with risks that include bleeding, esophageal injury and aspiration. Many of these factors contribute to poor patient compliance with AASLD recommendations. Noninvasive methods for detecting, grading, and risk stratification of esophageal varices are needed. Imaging tests such as ultrasound elastography to measure liver stiffness have been proposed as a method to predict the presence of varices but have insufficient accuracy to eliminate the need for endoscopy.10 An ideal biomarker to screen for esophageal varices would be part of the routine standard of care of patients with cirrhosis, noninvasive, rapid, less expense than endoscopy, highly accurate, highly reproducible, and would require no sedation, provide a quantitative measure of the size of the varices, provide a mechanisms to assess the risk of future bleeding, allow for an assessment for other signs of portal hypertension, and provide other benefits to the patient (e.g. detect ascites and HCC and assess liver vasculature). Computed tomography (CT) is standard of care to screen for HCC. CT is noninvasive, rapid, less expensive than endoscopy, requires no sedation, provides a quantitative measure of the size of the varices, and allows for assessment of para-esophageal varices, varices in other body locations, ascites, other signs of portal hypertension, patency of liver vasculature, and detection, diagnosis and staging of HCC. Conventional Single-Energy CT (SECT) has relatively high accuracy in prospective studies for detection of any and large varices and has higher inter-observer agreement than endoscopy (kappa 0.56 vs. 0.36, respectively). Major deficiencies in SECT include relatively suboptimal contrast opacification of gastroesophageal varices, inconsistent accuracy that is dependent upon SECT image acquisition technique, and suboptimal stratification of the risk of bleeding (e.g. inability to detect red wale sign) compared to endoscopy. Dual-Energy CT (DECT) improves the contrast-to-noise ratio by 60% compared to SECT. DECT also improves visualization by taking advantage of the markedly increased attenuation of iodine at photon energy levels just above the iodine K edge (33 keV). Using material decomposition techniques, DECT can map the concentration of iodine on a voxel by voxel basis which, combined with higher contrast to noise resolution on these same type of images, improves the conspicuity of enhancing structures. DECT is routinely used to screen for HCC in cirrhotic patients. While DECT has been shown to improve image quality and portal venography compared to SECT, the accuracy of DECT for screening for varices has not been reported. The primary objective is to determine the accuracy of dual energy CT for detecting any varices and high-risk varices in patients with cirrhosis presenting for upper gastrointestinal endoscopy.

Interventions

DIAGNOSTIC_TESTDuel Energy CT

Enrolled subjects will complete a dual energy ct for evaluation of esophageal varices

Sponsors

University of Alabama at Birmingham
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients with cirrhosis presenting to UAB Endoscopy for surveillance endoscopy to detect and grade gastroesophageal varices

Exclusion criteria

* Inability to provide written informed consent * History of bleeding gastroesophageal varices, variceal intervention or portosystemic shunt * Prior liver transplant * History of malignancy * Severe chronic kidney disease with estimated glomerular filtration rate (GFR) \< 30 mL/min/1.73 m2 * Presence of acute kidney injury * Prior iodinated contrast allergy * Patient weight \>300 lbs * Multiphasic liver CT within 3 months of upper endoscopy * Pregnancy * Inclusion of all races and ethnic groups are eligible for this trial. There is no bias towards age or race in this trial. The trial is open the accrual of women and men.

Design outcomes

Primary

MeasureTime frameDescription
To Measure the Accuracy of Dual Energy CT for Detecting Any Varices and High-risk Varices in Patients With Cirrhosis Presenting for Upper Gastrointestinal Endoscopy.DECT will be no more than 2 weeks from the time of endoscopyVarices on dual energy CT will be graded as follows: 0 = no varices, 1 = small \[\<5 mm\] varices, and 2 = large / high risk \[\>= 5 mm\] varices. The reference standard for this outcome will be grading of varices on endoscopy (0 = no varices, 1 = small (\< 5 mm) varices, and 2 = large (\>=5 mm) varices.

Countries

United States

Participant flow

Participants by arm

ArmCount
Dual Energy CT
Duel Energy CT: Enrolled subjects will complete a dual energy ct for evaluation of esophageal varices
11
Total11

Baseline characteristics

CharacteristicDual Energy CT
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
1 Participants
Age, Categorical
Between 18 and 65 years
10 Participants
Age, Continuous59 years
Ethnicity (NIH/OMB)
Hispanic or Latino
0 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
11 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
3 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
8 Participants
Sex: Female, Male
Female
6 Participants
Sex: Female, Male
Male
5 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 11
other
Total, other adverse events
0 / 11
serious
Total, serious adverse events
0 / 11

Outcome results

Primary

To Measure the Accuracy of Dual Energy CT for Detecting Any Varices and High-risk Varices in Patients With Cirrhosis Presenting for Upper Gastrointestinal Endoscopy.

Varices on dual energy CT will be graded as follows: 0 = no varices, 1 = small \[\<5 mm\] varices, and 2 = large / high risk \[\>= 5 mm\] varices. The reference standard for this outcome will be grading of varices on endoscopy (0 = no varices, 1 = small (\< 5 mm) varices, and 2 = large (\>=5 mm) varices.

Time frame: DECT will be no more than 2 weeks from the time of endoscopy

Population: The study was ended prematurely due to covid. This data was not collected.