Skip to content

Relationship Between Hemodynamic Change and Fluid Removed During Hemodialysis

Relationship Between Hemodynamic Change and Fluid Removed During Hemodialysis Measured by Non-invasive Monitor

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03901794
Enrollment
60
Registered
2019-04-03
Start date
2017-05-06
Completion date
2018-11-30
Last updated
2019-04-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hemodialysis Complication, Hemodialysis-Induced Symptom

Brief summary

Relationship between hemodynamic change and fluid removed during hemodialysis measured by non-invasive monitor

Detailed description

By applying non-invasive hemodynamic monitors (ex. ClearSight, I-COM), the trends of mean arterial pressure (MAP), stroke volume (SV), cardiac index (CI) and calculated systemic vascular resistance (SVR) were collected along with volume removal by hemodialysis on ESRD patients. All data were compared and analyzed to detect the sequential body volume status as well as the autonomic responses during hemodialysis.

Interventions

DEVICENon-invasive hemodynamic monitor

MAP, HR, CO, SVI, from Non-invasive hemodynamic monitor

Sponsors

National Taiwan University Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
20 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1\. Patients who were schedured with regular hemodialysis for end-stage renal disease.

Exclusion criteria

1. Emergent hemodialysis 2. Medical conditions with poor peripheral circulation such as Raynaud's disease or PAOD 3. Skin defects or wounds over area to be applied for measurement (Wrist and fingers)

Design outcomes

Primary

MeasureTime frameDescription
fluid removed along with hemodialysis4 hoursthe fluid volume removed from hemodialysis (mL/hour),
changes of mean arterial pressure along with hemodialysis4 hoursrecord of mean arterial pressure (mmHg) per 30 minutes
changes of heart rate along with hemodialysis4 hoursrecord of heart rate (beats/ minute) per 30 minutes
changes of stroke volume along with hemodialysis4 hoursrecord of stroke volume (SV, (mL/ beat)per 30 minutes
changes of cardiac output along with hemodialysis4 hoursrecord of cardiac output ( liter/ minute)per 30 minutes

Countries

Taiwan

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 12, 2026