Skip to content

Focused Cardiac Ultrasound

Feasibility and Accuracy of Focused Cardiac Ultrasound Using an FDA Approved Hand-held Ultrasound Device in Outpatient Setting in Our Institution.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03887286
Enrollment
47
Registered
2019-03-22
Start date
2019-04-01
Completion date
2019-05-30
Last updated
2020-06-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pericardial Effusion, Septal Defect, Valvular Disease, Ventricular Dysfunction

Brief summary

To compare the images from standard cardiac ultrasound with images from a small hand-held device; to find out more about the feasibility and accuracy of a small hand-held ultrasound device.

Interventions

DEVICEPhilips EPIQ 7 ultrasound machine

Standard transthoracic echocardiography

DEVICEPhilips Lumify Broadband sector array transducer

Portable hand-held ultrasound device

Sponsors

University of Miami
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Patients presenting to pediatric cardiology clinic at Holtz Children's hospital requiring comprehensive or limited transthoracic echocardiogram. * Willing and able to provide informed consent or assent. * In clinically stable condition as assessed by the principal investigator.. * With adequate echocardiographic windows.

Exclusion criteria

* Patients with poor echocardiographic windows. * Patients who refuse informed consent. * Pregnant women. * Prisoners. * Patients deemed unfit to participate in the clinical trial as assessed by the principal investigator.

Design outcomes

Primary

MeasureTime frameDescription
Number of Patients Detected With Ventricular Dysfunction, Pericardial Effusion, Valvular Disorders, Septal Disorders, and Coronary Anomalies.Day 1Comparison of diagnostic ability of portable hand-held cardiac ultrasound with standard transthoracic echocardiography

Countries

United States

Participant flow

Participants by arm

ArmCount
Treatment Group
All participants to receive standard transthoracic echocardiogram and hand held echocardiogram Philips EPIQ 7 ultrasound machine: Standard transthoracic echocardiography Philips Lumify Broadband sector array transducer: Portable hand-held ultrasound device
47
Total47

Baseline characteristics

CharacteristicTreatment Group
Age, Continuous7.8 years
STANDARD_DEVIATION 8.6
Race and Ethnicity Not Collected— Participants
Sex: Female, Male
Female
19 Participants
Sex: Female, Male
Male
28 Participants
weight27.24 kg
STANDARD_DEVIATION 23.41

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 47
other
Total, other adverse events
0 / 47
serious
Total, serious adverse events
0 / 47

Outcome results

Primary

Number of Patients Detected With Ventricular Dysfunction, Pericardial Effusion, Valvular Disorders, Septal Disorders, and Coronary Anomalies.

Comparison of diagnostic ability of portable hand-held cardiac ultrasound with standard transthoracic echocardiography

Time frame: Day 1

ArmMeasureGroupValue (COUNT_OF_PARTICIPANTS)
Standard Transthoracic Echocardiogram InterventionNumber of Patients Detected With Ventricular Dysfunction, Pericardial Effusion, Valvular Disorders, Septal Disorders, and Coronary Anomalies.normal anatomy13 Participants
Standard Transthoracic Echocardiogram InterventionNumber of Patients Detected With Ventricular Dysfunction, Pericardial Effusion, Valvular Disorders, Septal Disorders, and Coronary Anomalies.minor cardiac abnormality9 Participants
Standard Transthoracic Echocardiogram InterventionNumber of Patients Detected With Ventricular Dysfunction, Pericardial Effusion, Valvular Disorders, Septal Disorders, and Coronary Anomalies.major cardiac abnormality25 Participants
Hand Held EchocardiographyNumber of Patients Detected With Ventricular Dysfunction, Pericardial Effusion, Valvular Disorders, Septal Disorders, and Coronary Anomalies.normal anatomy13 Participants
Hand Held EchocardiographyNumber of Patients Detected With Ventricular Dysfunction, Pericardial Effusion, Valvular Disorders, Septal Disorders, and Coronary Anomalies.minor cardiac abnormality4 Participants
Hand Held EchocardiographyNumber of Patients Detected With Ventricular Dysfunction, Pericardial Effusion, Valvular Disorders, Septal Disorders, and Coronary Anomalies.major cardiac abnormality23 Participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026