Skip to content

MDT-1118 Japan DT Study

A Prospective, Multi-Center, Single Arm Clinical Study to Evaluate the MDT-1118 Ventricular Assist Device System for Destination Therapy of Advanced Heart Failure

Status
Completed
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03884504
Acronym
MDT-1118 Japan
Enrollment
10
Registered
2019-03-21
Start date
2019-05-01
Completion date
2022-10-19
Last updated
2022-10-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Keywords

Advanced Heart Failure, Ventricular Assist Device System, Destination Therapy

Brief summary

To evaluate the safety and effectiveness of the MDT-1118 VAD in a patient population for destination therapy (long term support) of advanced heart failure. The collected data will be used to support Japan regulatory application in expanding market approval for destination therapy.

Interventions

DEVICEVentricular Assist Device System

Ventricular Assist Device System

Sponsors

Medtronic Cardiac Rhythm and Heart Failure
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
20 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Must be ≥20 years of age at consent 2. In judgment of body size, body surface area (BSA) and anatomy by Investigator, patient can be implanted MDT-1118 VAD. 3. Patients with advanced heart failure symptoms (Class IIIB or IV) who are: (patient must meet one of the following) 1. On optimal medical management, including dietary salt restriction and diuretics, for at least 45 out of the last 60 days and are failing to respond; or 2. In Class III or Class IV heart failure for at least 14 days, and dependent on intra-aortic balloon pump (IABP) for 7 days and/or inotropes for at least 14 days 4. Left ventricular ejection fraction ≤ 25% 5. LVAD implant is intended as destination therapy 6. Must be able to receive the MDT-1118 VAD 7. Female patients of childbearing potential must agree to use adequate contraceptive precautions (defined as oral contraceptives, intrauterine devices, surgical contraceptives or a combination of condom and spermicide) for the duration of the study 8. The patient has signed the informed consent form and advance directive 9. The patient and the family understand that destination therapy is end-of-life medical care.

Exclusion criteria

1. Patients with INTERMACS profile 1 2. Existence of any ongoing mechanical circulatory support (MCS) other than an intra-aortic balloon pump (IABP) 3. Prior cardiac transplant 4. History of confirmed, untreated abdominal/ thoracic aortic aneurysm \> 5 cm, or cardiac aneurysm or intraventricular septum rupture 5. Severe calcification in thoracic aorta 6. Cardiothoracic surgery within 14 days of implantation 7. Acute myocardial infarction within 14 days of implant as diagnosed by ST or T wave changes on the ECG, diagnostic biomarkers, ongoing pain and hemodynamic abnormalities as described in the guidelines published in ACC/AHA 2007 Guidelines for the Management of Patients with Unstable Angina/Non-ST-Elevation Myocardial Infarction1 8. Patients eligible for cardiac transplantation 9. On ventilator support for \> 72 hours within the four days immediately prior to implantation 10. Pulmonary embolus within 21 days of implantation as documented by computed tomography (CT) scan or magnetic resonance imaging (MRI) 11. Symptomatic cerebrovascular disease, stroke within 180 days of implantation or \> 80% stenosis of carotid or cranial vessels 12. Patient seems difficult to control device by oneself due to cerebral disorder 13. History of drug intoxication or alcohol dependence 14. Uncorrected moderate to severe aortic insufficiency. Correction may include repair or bioprosthesis at the time of implant 15. Severe right ventricular failure as defined by the anticipated need for right ventricular assist device (RVAD) support or extracorporeal membrane oxygenation (ECMO) at the time of screening or right atrial pressure \> 20 mmHg on multiple inotropes or right ventricular ejection fraction (RVEF) \<15% with clinical signs of severe right heart failure (e.g. Lower extremity edema, ascites or pleural effusions refractory to treatment with diuretics and two inotropic drugs) 16. Active, uncontrolled infection diagnosed by a combination of clinical symptoms and laboratory testing, including but not limited to, continued positive cultures, elevated temperature and white blood cell (WBC) count, hypotension, tachycardia, generalized malaise despite appropriate antibiotic, antiviral or antifungal treatment 17. Uncorrected thrombocytopenia or generalized coagulopathy (e.g., platelet count \< 75,000, INR \> 2.0 or PTT \> 2.5 times control in the absence of anticoagulation therapy) 18. Intolerance to anticoagulant or antiplatelet therapies or any other peri- or postoperative therapy that the investigator may administer based upon the patient's health status 19. Serum creatinine \> 3.0 mg/dL within 72 hours of implantation or requiring dialysis or ultrafiltration 20. Specific liver enzymes \[AST (SGOT) and ALT (SGPT\] \> 3 times upper limit of normal within 72 hours of implantation 21. A total bilirubin \> 3 mg/dL within 72 hours of implantation, or biopsy proven liver cirrhosis or portal hypertension 22. Patients with a mechanical heart valve 23. Etiology of heart failure is due to, or associated with, uncorrected thyroid disease, obstructive cardiomyopathy, pericardial disease, amyloidosis, active myocarditis or restrictive cardiomyopathy 24. History of severe COPD or severe restrictive lung disease (e.g FEV1 \<50%) or severe pulmonary hypertension 25. Participation in any other study involving investigational drugs or devices 26. Severe illness, other than heart disease, which would limit survival to \< 3 years 27. Peripheral vascular disease with rest pain or ischemic ulcers of the extremities 28. Pregnancy 29. Patient unwilling or unable to comply with study requirements 30. Technical obstacles, which pose an inordinately high surgical risk, in the judgment of the investigator 31. Inadequate family/social support 32. Systemic disease including collagen disease, insulin dependent severe diabetes or irreversible multi-organ failure.

Design outcomes

Primary

MeasureTime frameDescription
Success at 12 months with the following definitions of success and failureImplant to 12 monthsTherapy will be considered a success if, at the end of 12 months in the study: 1. The subject is alive; and 2. The subject has not had a stroke of Modified Rankin Score ≥ 4; and 3. The subject retains the originally implanted device, unless the device was removed due to heart recovery, or the patient is electively transplanted. Therapy will be considered a failure if, within the 12 months in the study: 1. The subject dies; or 2. The subject has a stroke of Modified Rankin Score ≥ 4; or 3. The device malfunctions or fails, requiring exchange, explantation, or urgent transplantation.

Secondary

MeasureTime frame
Incidence of all adverse events per INTERMACS definitionImplant to 12 months
Incidence of all device malfunctions per INTERMACS definitionImplant to 12 months
Health Status improvement, as measured by KCCQImplant to 12 months
Health Status improvement, as measured by EuroQol EQ-5D-5LImplant to 12 months

Countries

Japan

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026