Skip to content

Effect of Head Rotation on Efficacy of Face Mask Ventilation in Anesthetized Obese (BMI ≥ 35) Adults

A Prospective, Randomized, Non-Blinded, Crossover Controlled Clinical Trial Evaluating the Efficacy of Face Mask Ventilation With 45 Degree Head Rotation in Anesthetized Obese (BMI ≥ 35) Adults

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03876873
Enrollment
21
Registered
2019-03-15
Start date
2021-06-09
Completion date
2023-02-01
Last updated
2024-07-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Noninvasive Ventilation

Keywords

Face Mask, Obesity, Anesthetized Adult, Ventilation, Head Rotation

Brief summary

Mask ventilation is fundamental to airway management at the start of surgical procedures requiring general anesthesia. For general anesthesia, medications are provided that affect the entire body and lead to a loss of consciousness. Medical professionals perform mask ventilation by placing a plastic mask over a subjects mouth and nose to provide enough oxygen for the placement of a breathing tube. In this study, we expect that a 45 degree rotation of the head will increase the efficiency of mask ventilation.

Detailed description

Mask ventilation is a foundation of airway management after the initial induction of anesthesia. It allows for adequate oxygenation of the patient to buy enough time for intubation, during which the patient is not ventilated. However, in some patients mask ventilation may be difficult - older than 55 years, heavier (BMI \> 26 kg/m\^2), with no teeth, having a beard or sleep apnea. Inadequate ventilation, if not corrected, can result in decreasing oxygen saturation to dangerous levels - which could lead to devastating complications. As a result, the efficacy of mask ventilation is of critical importance to patient safety after the induction of anesthesia. A recent study proposed that mask ventilation could be improved simply by turning a patient's head. The study showed that rotating a patient's head to a 45 degree angle significantly improved mask ventilation when compared with the head placed in a neutral position. However, this study was done in patients with a BMI lass than 35. As such, the effects of head rotation on the efficacy of mask ventilation has not been studied in patients with a BMI of 35 and greater. Obesity (BMI ≥ 30 kg/m\^2) affects almost 40% of US adults and is one of the most prevalent health concerns in our society. It is a predictor of difficult mask ventilation because it is associated with increased upper airway obstruction, decreased airway patency, and decreased lung volumes such as functional residual capacity (FRC). If previous findings in regard to the effects of 45 degree head rotation on the efficacy of ventilation hold true in the obese patient, then this study will show that head rotation could be used as a simple way to improve the efficacy of mask ventilation for patients with a BMI of 35 and above.

Interventions

PROCEDUREHead Rotation During Face Mask Ventilation

Participants will receive face mask ventilation in either a neutral head position (practice standard position) or a head rotation position (45 degree angle).

DEVICEMedline Top Valve Anesthesia Mask

Face mask used per standard of care to provide oxygen to subjects before surgical procedures.

Sponsors

University of Missouri-Columbia
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Caregiver, Investigator)

Masking description

The surgeon, anesthesiologist, operating room staff, and participants will not know the group assignment at the time of subject recruitment. No blinding will occur during the clinical portion of the study or during data analysis.

Intervention model description

Participants will be assigned into one of two groups (per a randomization schedule) for face mask ventilation. The sequence of face mask ventilation head positions will be determined by group assignment. Each position will be performed for one minute. Group A: (1) neutral position, (2) head rotation, (3) neutral position. Group B: (1) head rotation, (2) neutral position, (3) head rotation.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age ≥ 18 years * ASA Physical Status Classification I-III * Body Mass Index (BMI) ≥ 35 kg/m\^2

Exclusion criteria

* Inability to obtain written informed consent * Pregnant or breastfeeding * Limited head rotation or neck extension * Subjects with expected or history difficult intubation * Large beard * Orogastric (OG)/nasogastric (NG) tube * Gastroesophageal Reflux Disease (GERD)

Design outcomes

Primary

MeasureTime frameDescription
Maximal and Average Expiratory Tidal Volume During Mask VentilationDay 1Measured in mL

Secondary

MeasureTime frameDescription
Maximal and Average Inspiratory Tidal Volume During Mask VentilationDay 1Measured in mL
Maximal and Average End-tidal CO2 (ETCO2) During Mask VentilationDay 1Measured in mm Hg
Maximal and Average Airway Flow During Mask VentilationDay 1Measured in L/min
Lowest and Delta O2 Saturation Drop on SpO2 During Mask VentilationDay 1Measured in % Delta O2 saturation drop is the difference between 100% oxygen saturation and the lowest oxygen saturation measured, e.g., 100 - 96 (lowest measured) = 4 (delta).
Lowest and Delta O2 Saturation Drop on SpO2 During IntubationDay 1Measured in % Delta O2 saturation drop is the difference between 100% oxygen saturation and the lowest oxygen saturation measured, e.g., 100 - 96 (lowest measured) = 4 (delta).

Countries

United States

Participant flow

Participants by arm

ArmCount
Group A
Head Rotation During Face Mask Ventilation. Step 1: Neutral Position (1 minute), Step 2: Head Rotation (1 minute), Step 3: Neutral Position (1 minute) Head Rotation During Face Mask Ventilation: Participants will receive face mask ventilation in either a neutral head position (practice standard position) or a head rotation position (45 degree angle). Medline Top Valve Anesthesia Mask: Face mask used per standard of care to provide oxygen to subjects before surgical procedures.
9
Group B
Head Rotation During Face Mask Ventilation. Step 1: Head Rotation (1 Minute), Step 2: Neutral Position (1 minute), Step 3, Head Rotation (1 Minute) Head Rotation During Face Mask Ventilation: Participants will receive face mask ventilation in either a neutral head position (practice standard position) or a head rotation position (45 degree angle). Medline Top Valve Anesthesia Mask: Face mask used per standard of care to provide oxygen to subjects before surgical procedures.
12
Total21

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudyPhysician Decision01

Baseline characteristics

CharacteristicGroup AGroup BTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
0 Participants1 Participants1 Participants
Age, Categorical
Between 18 and 65 years
9 Participants11 Participants20 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Black or African American
0 Participants1 Participants1 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Race (NIH/OMB)
White
9 Participants11 Participants20 Participants
Region of Enrollment
United States
9 participants12 participants21 participants
Sex: Female, Male
Female
7 Participants10 Participants17 Participants
Sex: Female, Male
Male
2 Participants2 Participants4 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 90 / 12
other
Total, other adverse events
0 / 91 / 12
serious
Total, serious adverse events
0 / 90 / 12

Outcome results

Primary

Maximal and Average Expiratory Tidal Volume During Mask Ventilation

Measured in mL

Time frame: Day 1

Population: Both groups' patients' heads were rotated, however, in the Neutral Position group the patients' heads started in neutral position, while the Head Rotation group's heads started in rotated position. Data were not collected for each 1-minute change within the groups.

ArmMeasureGroupValue (MEAN)Dispersion
Neutral PositionMaximal and Average Expiratory Tidal Volume During Mask VentilationMaximal expiratory tidal volume25 MilliliterStandard Deviation 11.39
Neutral PositionMaximal and Average Expiratory Tidal Volume During Mask VentilationAverage expiratory tidal volume21.96 MilliliterStandard Deviation 11.4
Head RotationMaximal and Average Expiratory Tidal Volume During Mask VentilationMaximal expiratory tidal volume26.52 MilliliterStandard Deviation 10.31
Head RotationMaximal and Average Expiratory Tidal Volume During Mask VentilationAverage expiratory tidal volume23.33 MilliliterStandard Deviation 9.9
Secondary

Lowest and Delta O2 Saturation Drop on SpO2 During Intubation

Measured in % Delta O2 saturation drop is the difference between 100% oxygen saturation and the lowest oxygen saturation measured, e.g., 100 - 96 (lowest measured) = 4 (delta).

Time frame: Day 1

Population: Both groups' patients' heads were rotated, however, in the Neutral Position group the patients' heads started in neutral position, while the Head Rotation group's heads started in rotated position. Data were not collected for each 1-minute change within the groups.

ArmMeasureGroupValue (MEAN)Dispersion
Neutral PositionLowest and Delta O2 Saturation Drop on SpO2 During IntubationLowest O2 saturation drop on SpO22.28 PercentageStandard Deviation 3.22
Neutral PositionLowest and Delta O2 Saturation Drop on SpO2 During IntubationDelta O2 saturation drop on SpO23.22 PercentageStandard Deviation 3.53
Head RotationLowest and Delta O2 Saturation Drop on SpO2 During IntubationLowest O2 saturation drop on SpO21.90 PercentageStandard Deviation 2.51
Head RotationLowest and Delta O2 Saturation Drop on SpO2 During IntubationDelta O2 saturation drop on SpO24.18 PercentageStandard Deviation 4.02
Secondary

Lowest and Delta O2 Saturation Drop on SpO2 During Mask Ventilation

Measured in % Delta O2 saturation drop is the difference between 100% oxygen saturation and the lowest oxygen saturation measured, e.g., 100 - 96 (lowest measured) = 4 (delta).

Time frame: Day 1

Population: Both groups' patients' heads were rotated, however, in the Neutral Position group the patients' heads started in neutral position, while the Head Rotation group's heads started in rotated position. Data were not collected for each 1-minute change within the groups.

ArmMeasureGroupValue (MEAN)Dispersion
Neutral PositionLowest and Delta O2 Saturation Drop on SpO2 During Mask VentilationLowest O2 saturation drop on SpO296.78 PercentageStandard Deviation 3.53
Neutral PositionLowest and Delta O2 Saturation Drop on SpO2 During Mask VentilationDelta O2 saturation drop on SpO23.22 PercentageStandard Deviation 3.53
Head RotationLowest and Delta O2 Saturation Drop on SpO2 During Mask VentilationLowest O2 saturation drop on SpO295.73 PercentageStandard Deviation 3.95
Head RotationLowest and Delta O2 Saturation Drop on SpO2 During Mask VentilationDelta O2 saturation drop on SpO24.18 PercentageStandard Deviation 4.02
Secondary

Maximal and Average Airway Flow During Mask Ventilation

Measured in L/min

Time frame: Day 1

Population: Both groups' patients' heads were rotated, however, in the Neutral Position group the patients' heads started in neutral position, while the Head Rotation group's heads started in rotated position. Data were not collected for each 1-minute change within the groups.

ArmMeasureGroupValue (MEAN)Dispersion
Neutral PositionMaximal and Average Airway Flow During Mask VentilationAverage airway flow97.95 Liters per minuteStandard Deviation 3.9
Neutral PositionMaximal and Average Airway Flow During Mask VentilationMaximal airway flow97.69 Liters per minuteStandard Deviation 3.21
Head RotationMaximal and Average Airway Flow During Mask VentilationMaximal airway flow98.03 Liters per minuteStandard Deviation 2.5
Head RotationMaximal and Average Airway Flow During Mask VentilationAverage airway flow96.78 Liters per minuteStandard Deviation 3.53
Secondary

Maximal and Average End-tidal CO2 (ETCO2) During Mask Ventilation

Measured in mm Hg

Time frame: Day 1

Population: Both groups' patients' heads were rotated, however, in the Neutral Position group the patients' heads started in neutral position, while the Head Rotation group's heads started in rotated position. Data were not collected for each 1-minute change within the groups.

ArmMeasureGroupValue (MEAN)Dispersion
Neutral PositionMaximal and Average End-tidal CO2 (ETCO2) During Mask VentilationMaximal end-tidal CO223 Millimeters of mercuryStandard Deviation 13.88
Neutral PositionMaximal and Average End-tidal CO2 (ETCO2) During Mask VentilationAverage end-tidal CO218.59 Millimeters of mercuryStandard Deviation 12.19
Head RotationMaximal and Average End-tidal CO2 (ETCO2) During Mask VentilationMaximal end-tidal CO231.36 Millimeters of mercuryStandard Deviation 5.26
Head RotationMaximal and Average End-tidal CO2 (ETCO2) During Mask VentilationAverage end-tidal CO223.93 Millimeters of mercuryStandard Deviation 6.41
Secondary

Maximal and Average Inspiratory Tidal Volume During Mask Ventilation

Measured in mL

Time frame: Day 1

Population: Both groups' patients' heads were rotated, however, in the Neutral Position group the patients' heads started in neutral position, while the Head Rotation group's heads started in rotated position. Data were not collected for each 1-minute change within the groups.

ArmMeasureGroupValue (MEAN)Dispersion
Neutral PositionMaximal and Average Inspiratory Tidal Volume During Mask VentilationMaximal inspiratory tidal volume415.48 MilliliterStandard Deviation 182.27
Neutral PositionMaximal and Average Inspiratory Tidal Volume During Mask VentilationAverage inspiratory tidal volume339.86 MilliliterStandard Deviation 243.76
Head RotationMaximal and Average Inspiratory Tidal Volume During Mask VentilationMaximal inspiratory tidal volume395.35 MilliliterStandard Deviation 158.73
Head RotationMaximal and Average Inspiratory Tidal Volume During Mask VentilationAverage inspiratory tidal volume296.45 MilliliterStandard Deviation 90.86

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026