Skip to content

The Effect of Knee Flexion Angle for Graft Fixation During Single-Bundle Anterior Cruciate Ligament Reconstruction

The Effect of Knee Flexion Angle for Graft Fixation During Single-Bundle Anterior Cruciate Ligament Reconstruction - A Multicentre, Patient and Assessor Blinded, Stratified, Two-arm Parallel Group Superiority Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03875807
Acronym
KFA-FIRM
Enrollment
204
Registered
2019-03-15
Start date
2014-04-16
Completion date
2019-12-01
Last updated
2020-05-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anterior Cruciate Ligament Injury

Keywords

ACL, ACL reconstruction, Knee Flexion Angle, Bone Patellar Tendon Bone

Brief summary

The overall aim of this study is to determine the effect of the knee flexion angle (KFA) of either 0 degrees, or 30 degrees (measured by sterile goniometer) during anterior cruciate ligament (ACL) fixation on postoperative outcomes following single-bundle ACL reconstruction with bone patellar tendon bone (BPTB) autograft. The specific aims of the current study include determining the effect of the knee flexion angle on 1) patient-reported outcomes; 2) postoperative extension loss; 3) antero-posterior (AP) knee stability; 4) rate of re-operation.

Detailed description

At the present time, there is no consensus about the position of the knee during tensioning anterior cruciate ligament (ACL) graft fixation at the time of reconstruction, although it can be assumed to be one of the key factors for successful ACL reconstruction (ACLR). In studies that have investigated transtibial ACLR, it was suggested that 20 degrees is the ideal KFA to optimize graft force and the relative Antero-Posterior (AP) tibiofemoral relationship, while several other authors have advocated fixation in full extension to avoid overconstraining the knee. In the setting of anatomic ACLR, it has been reported that the tensioning of the graft at 30 degrees of knee flexion was associated with loss of knee extension when the anatomic femoral tunnel was chosen. Previous studies have performed gait analysis during walking in 24 patients with ACLR with hamstring autograft where graft fixation was performed at 25 degrees of knee flexion. In these study, the trans tibial (TT) technique resulted in significantly greater anterior femoral translation than healthy controls during the swing phase and excessive tibial internal rotation (IR) was found at midstance. In knees repaired with the anteromedial portal (AMP) technique, subjects were significantly less extended (5 degrees) compared with controls in late stance phase. While the AMP technique has the potential to improve overall joint stability, patients were shown to have increased difficulty with knee extension. It has also been demonstrated that since the anteromedial (AM) and posterolateral (PL) bundles of the ACL are at their longest in knee extension, the best angle for fixation would be near full extension. The aforementioned studies support the concept that anatomic ACL has an increased likelihood of anisometry and as a result the chosen KFA for fixation becomes increasingly important. The lack of consensus regarding the optimal KFA in ACLR is reflected in the practice patterns of surgeons. A survey of Canadian Orthopaedic Surgeons demonstrated that 40% of surgeons fix the ACL at a 30 degree KFA while 30% perform fixation in full extension. The purpose of this study is to conduct a randomized controlled trial to determine if the KFA during ACLR graft fixation has an effect on postoperative outcomes. Patients undergoing single bundle BPTB ACLR will be randomized to have the surgical repair done with a KFA of either 0 degrees, or 30 degrees (measured by sterile goniometer) during anterior cruciate ligament (ACL) fixation. Patients will be followed for 24 months post surgery, with a number of qualitative patient surveys and clinical measurements being collected at 3, 6, 12 and 24 months post op, with changes being compared to baseline survey response and clinical measurement scores.

Interventions

PROCEDUREACLR done at 0 degrees KFA

Patients randomized to this arm will undergo the following intervention: Anterior Cruciate Ligament Reconstruction (ACLR) done at 0 degrees knee angle flexion (KFA)

PROCEDUREACLR done at 30 degrees KFA

Patients randomized to this arm will undergo the following intervention: Anterior Cruciate Ligament Reconstruction (ACLR) done at 30 degrees knee angle flexion (KFA)

Sponsors

Arthroscopy Association of North America
CollaboratorOTHER
Women's College Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Masking description

Patients, assessors, and data analysts will be blinded in regards to treatment status at all times. Surgeons cannot be blinded given the nature of the intervention. We do not anticipate any circumstance in which unmasking of the data management team, or data analysts will be required, or permissible

Intervention model description

A Multicentre, Pragmatic, Patient and Assessor Blinded, Stratified, Two-arm Parallel (1:1) Group Superiority Trial

Eligibility

Sex/Gender
ALL
Age
16 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Male and female patients older than 16 years old with an isolated anterior cruciate ligament injury as diagnosed by clinical examination and MRI * No pre-existing arthritis as defined by the Kellgren-Lawrence radiographic rating system * Patients treated with an initial period of rehabilitation to eliminate swelling, optimize quadriceps strength and restore range of motion * Surgical management with a transtibial or anteromedial portal single-bundle ACLR with bone patella tendon bone (BPTB) autograft by a fellowship-trained sports medicine surgeon. * Provision of Informed Consent

Exclusion criteria

* Acute ACL injuries that have not undergone an initial period of physical therapy in order to restore the aforementioned parameters * Associated grade III injury to the MCL (medial opening \>10mm at 30 degrees of knee flexion or any medial opening in extension); * Presence of a PCL or posterolateral corner injury * Lack of informed consent.

Design outcomes

Primary

MeasureTime frameDescription
Knee Injury and Osteoarthritis Outcome Score (KOOS)Completed 24 months post ACL repair at 0 or 30 degrees flexionThe KOOS questionnaire consists of 5 subscales; Pain, other Symptoms, Function in daily living (ADL), Function in sport and recreation (Sport/Rec) and knee related Quality of life (QOL). The previous week is the time period considered when answering the questions. Standardized answer options are given (5 Likert boxes) and each question is assigned a score from 0 to 4. A normalized score (100 indicating no symptoms and 0 indicating extreme symptoms) is calculated for each subscale.

Secondary

MeasureTime frameDescription
Knee Injury and Osteoarthritis Outcome Score (KOOS)Completed 3, 6 and 12 months post ACL repair at 0 or 30 degrees flexionThe KOOS questionnaire consists of 5 subscales; Pain, other Symptoms, Function in daily living (ADL), Function in sport and recreation (Sport/Rec) and knee related Quality of life (QOL). The previous week is the time period considered when answering the questions. Standardized answer options are given (5 Likert boxes) and each question is assigned a score from 0 to 4. A normalized score (100 indicating no symptoms and 0 indicating extreme symptoms) is calculated for each subscale.
Marx Activity Score questionnaireCompleted at 3, 6, 12, 24 months post ACL repair at 0 or 30 degrees flexionThe Marx Scale is a validated survey for orthopaedics that consists of four questions concerning four activities or actions: running, cutting, deceleration, and pivoting. The patient or survey respondent is asked to report on the frequency with which they performed the activity in their healthiest state within the past year. It is designed to be completed in less than one minute. The questionnaire is focused on actions that may be affected by disorders of the knee.
Loss of Extension on Operative KneeExtension is measured at 3, 6, 12 and 24 months post ACL repairExtension loss versus contralateral knee measured clinically in degrees with a goniometer
Side to side differences in Anterior Posterior joint stability as measured by the KT-1000 ArthrometerKT-1000 measurements are recorded at 3, 6,12 and 24 months post ACL repairThe KT-1000 knee arthrometer (KT-1000) is an objective instrument to measure anterior tibial motion relative to the femur for anterior cruciate ligament (ACL) reconstruction. Measurements are captured on both the operative and non operative knee, and recorded at 0 degrees and 25 degrees flexion with a support placed under the knee for the latter measurement
Rate of ReoperationPatients are followed for 24 months post initial ACL surgery to capture any instances of reoperation on the affected kneeRate of reoperation is recorded from date of original surgery to 24 months post original ACL repair, reoperations captured include retear of ACL, and any meniscus related tears.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026