Study to Test the Usability of a New Injector to Administer Contrast Media Into Humans for Diagnostic Purposes

Performance of Centargo - A Novel Piston-based Injection System for High Throughput in Contrast-enhanced Computed Tomography (CE CT)

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03875469
Acronym
PERCENT
Enrollment
425
Registered
2019-03-14
Start date
2019-06-21
Completion date
2020-03-10
Last updated
2021-03-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Computed Tomography

Keywords

Contrast-enhanced computed tomography (CECT), Injector

Brief summary

This study investigates if a new medical device, which injects contrast media and flushing solution into humans to increase the visibility of images taken of the human body for diagnostic purposes, is easier to handle, quicker and cheaper than an older injector.

Detailed description

The study compares an investigational injection system (Centargo) for computed tomography (CT) to a currently marketed injection system (Stellant MP) in terms of efficiency, cost, performance and user satisfaction (Part 1). In addition, the reliability of the new injection system Centargo is tested (Part 2).

Interventions

DEVICECentargo injector (BPI 1000045)

Contrast-enhanced computer tomography conducted with Centargo injector

DEVICEStellant MP injector

Contrast-enhanced computer tomography conducted with Stellant MP injector

Sponsors

Bayer
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult subjects referred for contrast-enhanced computer tomography using a power injector

Exclusion criteria

* Pregnant and lactating women * Subjects with know hypersensitivity to iodinated contrast media * Subjects with unacceptable renal function per local guidelines

Design outcomes

Primary

MeasureTime frame
Setup time of CT systems1 day
Change time for bottle/ bag containing contrast medium1 day
Patient setup time for the multi-patient set per day1 day
Teardown time of CT-system1 day
Number of multi-patient sets per day1 day

Secondary

MeasureTime frameDescription
Total cost for multi-patients set and disposables per patient and day1 day
Reason for change of multi-patient syringe set for the injection of contrast media prior to expiration at 24 hours1 day
Volume of unused contrast agent at teardown time1 day
Volume of unused saline at teardown time1 day
Flow rate of contrast agent through the injector1 day
Volume of contrast agent delivered through injector1 day
Injector-generated pressure1 day
Number of automated system alerts1 dayIncl. alerts due to communication loss, pressure limiting, air detection (Centargo only) and a full waste container (Centrago only).
Radiographer satisfaction with contrast-media injector by study-related questionnaireUp to 4.5 monthsQuestionnaire contains 14 questions on injectors, disposables and software, pertaining to 5 levels of user satisfaction (´Very easy´ to ´Very hard´). Levels of user satisfaction from different questions are not combined.
Number of errors requiring a CT-system reboot1 dayFor Centargo only (Part 2)

Countries

Australia, Netherlands

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026