Efficacy of Two Intermittent Subglottic Secretion

Efficacy of Intermittent Subglottic Secretion Lavage Combined With Aspiration Preventing Ventilator Associated Pneumonia in Patients With Severe Neurological Disease:A Single-center Randomized Controlled Trial

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03871985
Enrollment
234
Registered
2019-03-12
Start date
2019-03-15
Completion date
2020-01-15
Last updated
2019-03-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ventilator Associated Pneumonia

Keywords

ventilator-associated pneumonia, subglottic secretion drainage, endotracheal tube, length of mechanical ventilation

Brief summary

The purpose of this study is to determine the efficacy of intermittent subglottic secretion lavage combined with aspiration preventing ventilator associated pneumonia in patients with severe neurological disease

Detailed description

Ventilator-associated pneumonia (VAP) is a common and serious complication of mechanical ventilation. Many studies have shown that the accumulation of subglottic secretions above the endotracheal cuff plays an important role in the pathogenesis of VAP. Subglottic secretion drainage (SSD) has been shown to be associated with a lower incidence of VAP in previous meta-analyses. Most studies in past reported that in the group of patients in whom endotracheal tube (ETT) was used and subglottic secretion drainage was applied compared to the group without subglottic secretion drainage.Very few studies compared two different methods of SSD,such as subglottic secretion lavage combined with aspiration or pure aspiration.The tubes need frequent cleaning as they often get blocked, especially the draining duct. This may be the reason why they are not commonly applied. However,subglottic secretion lavage combined with aspiration can reduce the incidence of tube blockage.So The purpose of this study is to determine the efficacy of intermittent subglottic secretion lavage combined with aspiration preventing ventilator associated pneumonia in patients with severe neurological disease.

Interventions

PROCEDURESubglottic secretion lavage combined with aspiration

Ventilator-associated pneumonia preventive measures were applied to all patients according to VAP bundle. Subglottic secretion lavage combined with aspiration was performed every 4 hours: Underwent preoxygenation before cuff pressure checking, and was maintained between 30 and 35 cmH2O. After aspirating secretions from the mouth, nose, and airway, 2-5 mL distilled sterile water was instilled through the subglottic lumen, and then the negative pressure suction device is connected with the outer opening of the side cavity of endotracheal intubation for suction with a negative pressure of 100 mmHg, and each suction was kept under 15 seconds. Repeat lavage and aspiration until the irrigation fluid is clear. After washing, cuff pressure checking and was maintained between 25 and 30 cmH2O.

Ventilator-associated pneumonia preventive measures were applied to all patients according to VAP bundle. Subglottic secretion aspiration was performed every 4 hours:Underwent preoxygenation before cuff pressure checking ,and was maintained between 25 and 30 cmH2O. After aspirating secretions from the mouth, nose, and airway, the negative pressure suction device is connected with the outer opening of the side cavity of endotracheal intubation for suction with a negative pressure of 100 mmHg, and each suction was kept under 15 seconds. Repeat suction until the secretion is completely absorbed.

Sponsors

The First Hospital of Jilin University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* patients aged between 18 and 80 years requiring mechanical ventilation for more than 72 hours with placement of an ETT( equipped with a dorsal suction catheter for subglottic secretion drainage)

Exclusion criteria

*

Design outcomes

Primary

MeasureTime frameDescription
Incidence of ventilator-associated pneumoniathrough study completion, an average of 10 monthsis pneumonia that occurs when an artificial airway is established and mechanically ventilated

Secondary

MeasureTime frameDescription
Incidence of draining duct blockagethrough study completion, an average of 10 monthsIf mucus flow stopped during subglottic suctioning with a sudden increase of the negative pressure in the proximal port of the suction suggesting a probable occlusion

Other

MeasureTime frameDescription
length of mechanical ventilationthrough study completion, an average of 10 monthslength of mechanical ventilation
The coincidence rate between pathogens of subglottic secretions and the lower respiratory tractthrough study completion, an average of 10 monthsThe coincidence rate between pathogens of subglottic secretions and the lower respiratory tract