Skip to content

Nationwide Long-term Outcome Surveillance of Physiomesh® vs. Other Meshes in Laparoscopic Incisional Hernia Repair

Nationwide Long-term Outcome Surveillance of Physiomesh® vs. Other Meshes in Laparoscopic Incisional Hernia Repair

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03846661
Enrollment
3338
Registered
2019-02-20
Start date
2010-01-01
Completion date
2019-02-01
Last updated
2019-02-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hernia, Abdominal, Postoperative Complications, Recurrence

Brief summary

The primary aim of the present study was to show how a national clinical register combined with other nationwide administrative registers may serve as a tool for pre- and post-marketing evaluation of new mesh and mesh fixation products for hernia surgery, using Physiomesh® versus other meshes designed for laparoscopic hernia repair as an example.

Detailed description

All adult (≥18 yrs) patients registered in the Danish Hernia Database (DHB) who underwent elective primary laparoscopic incisional hernia repair between January 1st 2010 and December 31st 2016. To obtain 100% follow-up data from DHB will be combined with administrative data from the Danish National Patient register. Patients will be followed from initial hernia repair until reoperation for recurrence, death, emigration outside Denmark or end of follow-up (november 2017). Physiomesh and other mesh repairs will be propensity score matched. Each patient in the Physiomesh® group will be matched with two patients treated with one of the other synthetic meshes. The Propensity score includes age, sex, year of surgery, diagnosis of chronic obstructive pulmonary disease, diagnosis of diabetes, diagnosis of obesity, Charlson comorbidity index and size of hernia defect The primary outcome: Difference in risk for a reoperation for recurrence between patients operated with Physiomesh® and patients operated with another synthetic mesh designed for laparoscopic repair. The secondary outcome will be rates of 30-day readmission, 30-day reoperation for complications (excluding hernia recurrence) as well as 30- and 90-day mortality.

Interventions

DEVICEPhysiomesh

difference in risk for recurrence and postoperative complication

Sponsors

Zealand University Hospital
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Register study

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
Yes

Inclusion criteria

* All patients registered in the Danish Hernia Database for a laparoscopic incisional hernia repair

Exclusion criteria

* If not registered for a laparoscopic incisional hernia repair in the Danish Hernia Database

Design outcomes

Primary

MeasureTime frame
Re-operation for recurrence rateup to 84 months

Secondary

MeasureTime frame
30-day readmission rate30 day
30-reoperation for complication rate30 day

Countries

Denmark

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026