Oxygen Reserve Index for Kids

Application and Validation of the New Oxygen Reserve Index in Infants < 2 Years Old

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03845192
Acronym
ORIkids
Enrollment
107
Registered
2019-02-19
Start date
2019-02-19
Completion date
2020-05-20
Last updated
2021-09-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypoxia

Brief summary

In infants less than two years old the new Oxygen Reserve Index (ORI) will be measured during general anaesthesia. It will evaluated if and how ORI-monitoring gives earlier warning of hypoxaemia than conventional oxygen saturation measurement.

Detailed description

The Oxygen Reserve Index (ORI) is a new development in multiple wavelength pulse oximetry, reflecting the arterial partial oxygen pressure (PaO2) continuously and non-invasively by an index. In contrast to established standard oxygen saturation (SpO2) measurements, ORI detects a drop of PaO2 until the threshold of 100 mmHg. During anaesthesia induction-associated apnoeic periods ORI may detect a drop of PaO2 early enough for the anaesthesiologist to interrupt the intubation procedure and re-start oxygenation. In contrast, due to the flat upper part of the oxyhaemoglobin dissociation curve, SpO2 stays at values above 90% until PaO2 falls below 60mmHg. At this point, SpO2 drops rapidly and a pro- longed hypoxic dip is the consequence. To avoid this potentially harmful hypoxic dip, continuous monitoring of PaO2 using ORI would be advantageous during anaesthesia induction phase. This clinical study aims to evaluate the time benefit between alarm of hypoxaemia by the ORI-monitoring and the start of the dropping of oxygen saturation. Pre-set and pre-described ORI-alarms will be checked for their utility and a new ORI-alarm will be defined that is potentially more useful. As secondary endpoints the study examines the correlation of ORI with PO2, the influence of patient or measurement characteristics on the correlation of ORI with PO2 and the influence of the measurement site on ORI-measurement.

Interventions

DEVICEORI measurement by Radical 97

ORI measurement is done from the beginning of the induction of anaesthesia until the end of the induction of anaesthesia or until the end of the stay in the operating theatre. The measurement to ORI is done by the Radical-97 device by Masimo®.

Sponsors

Johannes Gutenberg University Mainz
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
No minimum to 2 Years
Healthy volunteers
No

Inclusion criteria

* small infants \< 2 years scheduled for elective surgery with general anaesthesia.

Exclusion criteria

* emergency procedures, lack of informed consent of legal guardian

Design outcomes

Primary

MeasureTime frameDescription
time in seconds between ORI-dropping and dropping of SpO2during general anaesthesia of the infantAdditionally a potential better definition of ORI-alarm than the preset or previously reported ORI-alarm will be defined

Secondary

MeasureTime frame
correlation of ORI and PO2during general anaesthesia of the infant
influence of patient or measurement characteristics on the correlation of ORI and PO2during general anaesthesia of the infant
influence of measurement site on the correlation or ORI with PO2 and the influence of the measurement site on ORI measurementduring general anaesthesia of the infant