Vascular Calcification, Vertebral Fracture
Conditions
Keywords
observer variability, kauppila score, quantitative vertebral morphometry, computer assisted procedure, abdominal aorta, lumbar spine
Brief summary
BACKGROUND In the context of a progressively aging population, monitoring the status of Vascular Calcifications (VC) and Vertebral Fractures (VF) over time would be of primary importance, as VC and VF are recognized to be hallmarks of severe cardiovascular events (hospitalization and/or death) and hip fractures respectively, and VF represent an under-diagnosed cause of progressive disability and pain on its own. Moreover, there is an acknowledged relationships between VC and VF. However, data about the emergence/progression of VC and the emergence/worsening of VF over time are lacking. This is likely due to the absence of monitoring instruments for VC and VF that are both precise and easily accessible/applicable. OBJECTIVE This study aims to define the observer variability of a new software developed by the study sponsor and collaborators, called Calcify2D. Calcify2D offers physicians a computer-assisted procedure to simultaneously score vascular calcifications at the abdominal aorta and lumbar vertebral fractures (according to Quantitative Vertebral Morphometry principles) based on a latero-lateral thoracolumbar spine radiography. Secondary aims are the validation of the scores obtained from latero-lateral thoracolumbar spine radiography with more invasive and/or costly gold-standard imaging modalities (Computed Tomography for VC, Magnetic Resonance for VF) that may have been acquired near-simultaneously to radiographs on the patients enrolled for the study. STUDY DESIGN Not-for-profit monocentric observational study to be conducted on the diagnostic images of the thoracolumbar spine already collected at Istituto Ortopedico Rizzoli (IOR) within a previous interventional study. Scoring of VC and VF will be performed by four clinicians from four relevant specialties, chosen among those who may often see VC and VF and are already familiar with the traditional scoring systems for both VC and VF (one radiologist and one spine orthopaedics from IOR, one nephrologist from the National Research Council and one internist from University of Padua). Each clinician will assess all radiographs to score VC and QVM, both via computer assisted procedures and via traditional visual inspection. To avoid bias, an interval of at least one week will be left between the computer assisted and visual scoring. To define intra-observer variability (i.e. repeatability), the whole dataset will be re-assessed three times.
Interventions
Radiographs showing VC will be used to assess whether the computer assisted VC scoring (primary objective) and Quantitative Vertebral Morphometry (QVM, limited to lumbar spine, secondary objective n.1) through the Calcify2D software are less variable with respect to the traditional visual scoring of VC and QVM.
Sponsors
Study design
Eligibility
Inclusion criteria
* Patients included in a previous interventional study (VTP vs KYPHO) of the sponsor. * Availability of diagnostic images (Dorso-lumbar radiographies taken in L-L projection). * Rx images will be screened for the presence of VC, retaining only those showing VC. * Informed consent obtained prior to any study analysis-evaluation.
Exclusion criteria
* Images showing severe artefacts (usually due to presence of metallic devices) that alter the grayscale range and hinder correct identification of VC and vertebral fractures
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Observer variability in scoring Vascular Calcification at the abdominal aorta | through study completion, 1 year at maximum | Observer variability (repeatability and reproducibility) in the assessment of vascular calcifications at the abdominal aorta according to a widely adopted scoring system (Kauppila et al., 1997): comparison between computer assisted and visual scoring. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Observer variability in scoring Vertebral Fractures at the lumbar spine | through study completion, 1 year at maximum | Observer variability (repeatability and reproducibility) in the assessment of vertebral fractures in the lumbar spine according to Quantitative Vertebral Morphometry (Genant et al., 2000): comparison between computer assisted and visual scoring. |
| Accuracy of computer assisted VC score | through study completion, 1 year at maximum | Accuracy of VC score computed by Calcify2D software will be tested against a gold standard CT-based score |
| Accuracy of computer assisted QVM | through study completion, 1 year at maximum | Accuracy of QVM score computed by Calcify2D software will be tested for the detection of mild vertebral fractures against gold standard Magnetic Resonance imaging |
Countries
Italy