Skip to content

Use of Transient Elastogaphy to Assess Diaphragm Function in Mechanically Ventilated Patients

Evaluation of Diaphragmatic Function in Mechanically Ventilated Patients With Transient Shear Wave Elastography

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03832231
Acronym
Elasto-ICU
Enrollment
30
Registered
2019-02-06
Start date
2019-02-14
Completion date
2020-07-09
Last updated
2021-03-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intensive Care Unit, Ventilator Weaning

Keywords

Shear wave elastography, Ultrasonography, Transdiaphragmatic pressure, Diaphragmatic function, Mechanical ventilation

Brief summary

Mechanical ventilation is a life-saving treatment that can be associated with diaphragm dysfunction, a potentially deleterious acquired disability. It may be the consequence of disuse - under mechanical ventilation, respiratory muscles are unloaded - or the consequence of muscle overuse because of insufficient unloading. Evaluating diaphragm function is therefore crucial to optimally tailor the ventilator assistance. Measurement of transdiaphragmatic pressure (Pdi) is the reference method to assess diaphragm function but it invasiveness hinders the generalization of its use. Previous studies have reported that ultrasound can quantify diaphragm thickening and that diaphragm thickening fraction (TFdi) is a good marker of diaphragm function. Since diaphragm becomes stiffer when it contracts, the investigators aim at exploring whether the measurement of diaphragm stiffness by transient shear wave elastography would improve the evaluation of diaphragm function with ultrasound. Therefore, the objectives of the study are to evaluate the performance of transient shear wave elastography applied to the diaphragm to estimate Pdi in mechanically ventilated patients as compared to TFdi and to correlate the changes in elastography derived indices, in TFdi and in Pdi into different ventilatory conditions and during a spontaneous breathing trial. Pdi will be obtained using catheters positioned in patients' stomachs and esophagus and diaphragm stiffness will be assessed by measuring the shear modulus of the diaphragm with a dedicated ultrasound machine (Aixplorer, Ultrasonic). TFdi will be also measured as previously reported. Pdi, TFdi and shear modulus will be measured at the end of each four following 10 minutes-conditions: 1) baseline with initial ventilator settings (set by the physician in charge of patient); 2) 25%-increase in pressure support and initial PEEP; 3) 25%-decrease in pressure support and initial PEEP and 4) initial level of pressure support and ZEEP. Finally, the same measurements will be done at the beginning of a 30 minutes spontaneous breathing trial.

Detailed description

Objective : The main objective is to correlate ultrasound indices (thickness, thickening, rigidity) to the measurement of transdiaphragmatic pressure in the evaluation of the diaphragmatic function of patients under mechanical ventilation. Secondary objectives are: 1. Correlate thickening of the diaphragm with Pdi, 2. Correlate diaphragmatic thickening with diaphragmatic stiffness 3. Describe these correlations under different levels of pressure ventilatory support, 4. Describe the evolution of diaphragmatic stiffness, thickening and Pdi pressure during a ventilator liberating trial. The primary endpoint is the measurement of Pdi. The secondary endpoints are the diaphragm thickening fraction and diaphragm stiffness. Methods : The Pdi will be obtained by measuring the esophageal and gastric pressures through nasogastric tube equipped with balloons. The position of each of the balloons will be checked by displaying the esophageal and gastric pressure lines. The intragastric position will be confirmed by mild abdominal compression. The oesophageal position is based on visualization of cardiac artifacts on the pressure pattern and signal deflations related to inspiratory movements. The signals of the esophageal and gastric pressures will be displayed continuously and their resultant - transdiapragmatic pressure - will be automatically calculated in real time by the software. It will also record pressure in the airways at the endotracheal tube. Patients will be placed in half-sitting position to allow better recognition of the diaphragm. Using the ultrasound system Aixplorer® (Aix en Provence, France V9), equipped with a high resolution probe (6 MHz). The probe will be positioned at the intercostal space above the tenth rib on the right axillary line and directed perpendicular to the diaphragm (apposition zone). The measurements will be performed offline and the calculation of the thickening fraction will be performed in blind clinical conditions. The diaphragmatic elastography will be determined using the same ultrasound system (Aixplorer®, Aix en Provence, France V9, provided with a high resolution probe (SL10-2, central frequency, 6 MHz)). The anatomical approach is the same as the intercostal approach described previously. After finding the diaphragm in B mode, a transition to SWE (elastography) mode will be performed. Three successive measurements will be made on the same region of interest, the average of the three measurements will be retained. The variation of the shear modulus during the inspiratory time will also be calculated post hoc. As for standard ultrasound, records analysis will be performed in blind conditions. Pdi, ultrasound derived indices and shear wave modulus will be measured under several conditions. 1. At baseline: initial ventilator settings set by the physician in charge of patient 2. 25%-increase in pressure support and initial PEEP during 10 minutes 3. 25%-decrease in pressure support and initial PEEP during 10 minutes 4. initial level of pressure support without PEEP (PEEP = 0) during 10 minutes 5. Measurement of the maximal inspiratory pressure during an inspiratory occlusion maneuver lasting 20 seconds. 6. A 30 minutes Ventilator liberating trial without PEEP nor Pressure Support (CPAP=0)

Interventions

DEVICEShear Wave Elastography

Ultrasound technology to assess tissue stiffness

Sponsors

Assistance Publique - Hôpitaux de Paris
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

All patients receiving mechanical ventilation and having spontaneous efforts will be eligible if they meet the following criteria: Inclusion criteria * Age ≥ 18 years old * Intubation and mechanical ventilation since 24 hours * Failure to a first ventilator liberating trial * nasogastric feeding tube in place * readiness criteria to undertake a ventilator liberating trial (Boles et al. ERJ 2007) * patient written consent or next of kin written consent in case of physical inability of the patient to sign the consent form * french social Health Service registration

Exclusion criteria

* pregnancy * protective administrative control * patient's refusal * contra indications to the insertion of esophageal and gastric balloons * allergy to topical anesthetic * impossible weaning (full dependance to mechanical ventilation)

Design outcomes

Primary

MeasureTime frameDescription
Change in transdiaphragmatic pressureThrough patient participation, an average of 1 dayReference method to assess diaphragm function computed as the difference between esophageal pressure and gastric pressure

Secondary

MeasureTime frameDescription
Change in diaphragm thickness and thickening as expressed by the thickening fraction (ratio of the difference between inspiratory and expiratory thickness over expiratory thickness).Through patient participation, an average of 1 dayUsing the ultrasound system Aixplorer® (Aix en Provence, France V9), equipped with a high resolution probe (6 MHz), anatomical structures will be identify using B-mode. A switch to TM-mode will allow us to measure the thickening fraction. A second switch to shear wave elastography allows to identify an elastography map of the diaphragm and calculate an average of the shear wave modulus.
Change in diaphragm stiffnessThrough patient participation, an average of 1 dayUsing the ultrasound system Aixplorer® (Aix en Provence, France V9), equipped with a high resolution probe (6 MHz), anatomical structures will be identify using B-mode. A switch to TM-mode will allow us to measure the thickening fraction. A second switch to shear wave elastography allows to identify an elastography map of the diaphragm and calculate an average of the shear wave modulus.
Success or failure at the spontaneous breathing trialThrough patient participation, an average of 1 dayPresence of clinical intolerance criteria according to Boles et al. ERJ 20107

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 25, 2026