Skip to content

Evaluation of the Accuracy of Full Digital Workflow for Guided Implant Surgery Using the R2 Gate Software

Evaluation of the Accuracy of Full Digital Workflow for Guided Implant Surgery Using the R2 Gate Software - a Randomized Clinical Trial (RCT)

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03814655
Acronym
DIGIMPLGD
Enrollment
54
Registered
2019-01-24
Start date
2019-07-01
Completion date
2020-07-13
Last updated
2020-07-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Partially Edentulous Mandible, Partially Edentulous Maxilla

Keywords

Dental implants, digital workflow, guided surgery

Brief summary

The primary aim of the present study is to compare the accuracy of a full digital workflow for dental implants insertion to a partially digital workflow, for a limited edentulous space (1 to 3 dental units), in the maxilla or mandible.

Detailed description

Improvements of dental digital technologies are nowadays enabling clinicians to take the digital impressions of the dental arches, therefore avoiding the use of conventional impression materials. Digital impression procedures are claimed to be an approach to improve the accuracy of dental restorations by minimizing the error prone to conventional impression and gypsum model casting, enabling a high degree of standardization. Patients often prefer intraoral scan when compared to the traditional impression. Digital impression is also recommended when patients have remaining teeth that are extremely mobile or misaligned, due to the risk of exfoliation during the conventional impression procedure. Despite its poor scientific and clinical evidence, the use of digital technologies into the daily practice registers a rapidly growing. The precision of digital impressions depends on two different parameters: the resolution of the optical scanning system, and the precision of the matching algorithm which may significantly influence the precision of full arch scans. In order to minimize the effect of matching artifacts, only small parts of the dental arch in close vicinity of the teeth are recommended to be scanned. For prosthetic restoration purpose, several studies regarding the accuracy of digital vs analogue impression have been performed, but none comparing the accuracy of digital vs partially digital workflow for prosthetically driven guided dental implant insertion.

Interventions

PROCEDUREFull digital workflow

Dental implants will be inserted usig a surgical guide performed after prosthetically driven treatment planning. The workflow will be full digital.

PROCEDUREPartially digital workflow

Dental implants will be inserted usig a surgical guide performed after prosthetically driven treatment planning. The workflow will be partially digital.

Sponsors

Carol Davila University of Medicine and Pharmacy
CollaboratorOTHER
MINEC
CollaboratorUNKNOWN
Concordia Dent Srl
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Investigator, Outcomes Assessor)

Intervention model description

54 partially edentulous patients filling the inclusion criteria and with signed consent form are expected to be enrolled in this RCT. Each patient will be randomly assigned to one of the following protocol for dental implant insertion: * Full digital workflow (n=27 patients/sites), * Partially digital workflow (n=27 patients/sites).

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
Yes

Inclusion criteria

* Kennedy Class III partially edentulism with 3 or less missing teeth, * Good general health with no contraindications for implant surgery, * Acceptance of dental implant treatment, * Acceptance of 1 or 2 CBCTs.

Exclusion criteria

* Limited bone volume with stadial bone graft requirement, * Limited mouth opening (impossible to use the surgical stent), * Parkinson disease (impossible to perform an accurate CBCT).

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of dental implant insertion6 weeksAccuracy is described, by the International Organization for Standardization (ISO) standard 5725-1, through the use of two parameters: trueness and precision. Trueness refers to the deviation between the actual dimension of the measured object and the resulting measurement, while precision indicates how closely repeated the measurements in a set are.

Countries

Romania

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 20, 2026